메뉴 건너뛰기




Volumn 41, Issue 6, 2010, Pages 660-663

Imaging modalities for localization of an iStent®

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM;

EID: 79953234554     PISSN: 15428877     EISSN: None     Source Type: Journal    
DOI: 10.3928/15428877-20100929-02     Document Type: Article
Times cited : (14)

References (15)
  • 1
    • 58749117403 scopus 로고    scopus 로고
    • Coexistent primary open-angle glaucoma and cataract: Preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent
    • Spiegel D, García-Feijoó J, García-Sánchez J, Lamielle H. Coexistent primary open-angle glaucoma and cataract: preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent. Adv Ther. 2008;25:453-464.
    • (2008) Adv Ther , vol.25 , pp. 453-464
    • Spiegel, D.1    García-Feijoó, J.2    García-Sánchez, J.3    Lamielle, H.4
  • 2
    • 34247895558 scopus 로고    scopus 로고
    • Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma
    • Spiegel D, Wetzel W, Haffner DS, Hill RA. Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma. Adv Ther. 2007;24:161-170. (Pubitemid 46700875)
    • (2007) Advances in Therapy , vol.24 , Issue.1 , pp. 161-170
    • Spiegel, D.1    Wetzel, W.2    Haffner, D.S.3    Hill, R.A.4
  • 3
    • 64549139671 scopus 로고    scopus 로고
    • Use of novel devices for control of intraocular pressure
    • Minckler DS, Hill RA. Use of novel devices for control of intraocular pressure. Exp Eye Res. 2009;88:792-798.
    • (2009) Exp Eye Res , vol.88 , pp. 792-798
    • Minckler, D.S.1    Hill, R.A.2
  • 4
    • 77349119622 scopus 로고    scopus 로고
    • Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma: Randomized double-masked clinical trial
    • Fea AM. Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma: randomized double-masked clinical trial. J Cataract Refract Surg. 2010;36:407-412.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 407-412
    • Fea, A.M.1
  • 5
    • 78650467470 scopus 로고    scopus 로고
    • Glaukos iStent trabecular micro-bypass
    • Nichamin LD. Glaukos iStent trabecular micro-bypass. Middle East Afr J Ophthalmol. 2009;16:138-140.
    • (2009) Middle East Afr J Ophthalmol , vol.16 , pp. 138-140
    • Nichamin, L.D.1
  • 6
  • 8
    • 40049103467 scopus 로고    scopus 로고
    • Anterior segment imaging: Ultrasound biomicroscopy and anterior segment optical coherence tomography
    • DOI 10.1097/ICU.0b013e3282f40bba, PII 0005573520080300000007
    • Nolan W. Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography. Curr Opin Ophthalmol. 2008;19:115-121. (Pubitemid 351322813)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.2 , pp. 115-121
    • Nolan, W.1
  • 12
    • 0034068551 scopus 로고    scopus 로고
    • Quantitative assessment of the anterior segment using ultrasound biomicroscopy
    • DOI 10.1097/00055735-200004000-00012
    • Ishikawa H, Liebmann JM, Ritch R. Quantitative assessment of the anterior segment using ultrasound biomicroscopy. Curr Opin Ophthalmol. 2000;11:133-139. (Pubitemid 30164035)
    • (2000) Current Opinion in Ophthalmology , vol.11 , Issue.2 , pp. 133-139
    • Ishikawa, H.1    Liebmann, J.M.2    Ritch, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.