메뉴 건너뛰기




Volumn 11, Issue 2, 2000, Pages 133-139

Quantitative assessment of the anterior segment using ultrasound biomicroscopy

Author keywords

[No Author keywords available]

Indexed keywords

ACCOMMODATION; ANTERIOR EYE SEGMENT; BIOMICROSCOPY; CLOSED ANGLE GLAUCOMA; HUMAN; IMAGE ANALYSIS; IRIS; MEASUREMENT; PATHOPHYSIOLOGY; PRESBYOPIA; PRIORITY JOURNAL; REVIEW;

EID: 0034068551     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/00055735-200004000-00012     Document Type: Review
Times cited : (125)

References (43)
  • 2
    • 4243801595 scopus 로고    scopus 로고
    • The hidden information within ultrasound biomicroscopy (UBM) images
    • Sugimoto M, Ishikawa H, Esaki K, et al.: The hidden information within ultrasound biomicroscopy (UBM) images [abstract]. Invest Ophthalmol Vis Sci 1998, 39(suppl):S1032.
    • (1998) Invest Ophthalmol Vis Sci , vol.39 , Issue.SUPPL.
    • Sugimoto, M.1    Ishikawa, H.2    Esaki, K.3
  • 4
    • 0028331269 scopus 로고
    • Ultrasound biomicroscopy in pigment dispersion syndrome
    • Potash SD, Tello C, Liebmann J, et al.: Ultrasound biomicroscopy in pigment dispersion syndrome. Ophthalmology 1994, 101:332-339.
    • (1994) Ophthalmology , vol.101 , pp. 332-339
    • Potash, S.D.1    Tello, C.2    Liebmann, J.3
  • 5
    • 0028020440 scopus 로고
    • Measurement of ultrasound biomicroscopy images: Intraobserver and interobserver reliability
    • Tello C, Liebmann JM, Potash SD, et al.: Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability. Invest Ophthalmol Vis Sci 1994, 35:3549-3552.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 3549-3552
    • Tello, C.1    Liebmann, J.M.2    Potash, S.D.3
  • 6
    • 0031820198 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy. I. Precision of measurements
    • Urbak SF: Ultrasound biomicroscopy. I. Precision of measurements. Acta Ophthalmol Scand 1998, 76:447-455.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 447-455
    • Urbak, S.F.1
  • 7
    • 0031757658 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements
    • Urbak SF, Pedersen JK, Thorsen TT: Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements. Acta Ophthalmol Scand 1998, 76:546-549.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 546-549
    • Urbak, S.F.1    Pedersen, J.K.2    Thorsen, T.T.3
  • 8
    • 0032738125 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy dark room provocative testing: A quantitative method for estimating anterior chamber angles
    • Ishikawa H, Esaki K, Liebmann JM, et al: Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angles. Jpn J Ophthalmol 1999, 43:526-534. Reports that the position of the iris insertion on the ciliary face could be a good predictor of dark room provocative test by measuring ARA on UBM images.
    • (1999) Jpn J Ophthalmol , vol.43 , pp. 526-534
    • Ishikawa, H.1    Esaki, K.2    Liebmann, J.M.3
  • 9
    • 0025166441 scopus 로고
    • Subsurface ultrasound microscopic imaging of the intact eye
    • Pavlin CJ, Sherar MD, Foster FS: Subsurface ultrasound microscopic imaging of the intact eye. Ophthalmology 1990, 97:244-250.
    • (1990) Ophthalmology , vol.97 , pp. 244-250
    • Pavlin, C.J.1    Sherar, M.D.2    Foster, F.S.3
  • 10
    • 0030897079 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic imaging of the anterior aspect of peripheral choroidal melanomas
    • Maberly DA, Pavlin CJ, McGowan HD, et al.: Ultrasound biomicroscopic imaging of the anterior aspect of peripheral choroidal melanomas. Am J Ophthalmol 1997, 123:506-514.
    • (1997) Am J Ophthalmol , vol.123 , pp. 506-514
    • Maberly, D.A.1    Pavlin, C.J.2    McGowan, H.D.3
  • 11
    • 0031711620 scopus 로고    scopus 로고
    • High-frequency ultrasound biomicroscopy versus ultrasound and optical pachymetry for the measurement of corneal thickness
    • Pierro L, Conforto E, Resti AG, et al.: High-frequency ultrasound biomicroscopy versus ultrasound and optical pachymetry for the measurement of corneal thickness. Ophthalmologica 1998, 212(suppl 1):1-3.
    • (1998) Ophthalmologica , vol.212 , Issue.SUPPL. 1 , pp. 1-3
    • Pierro, L.1    Conforto, E.2    Resti, A.G.3
  • 12
    • 0032972071 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy. III. Accuracy and agreement of measurements
    • Urbak SF: Ultrasound biomicroscopy. III. Accuracy and agreement of measurements. Acta Ophthalmol Scand 1999, 77:293-297. Confirms that quantitative measurement on UBM images is highly reliable and accurate in comparison with scanning electron microscopy.
    • (1999) Acta Ophthalmol Scand , vol.77 , pp. 293-297
    • Urbak, S.F.1
  • 13
    • 0013643645 scopus 로고
    • A new method of quantifying angle measurements based on ultrasound biomicroscopy
    • Ishikawa H, Uji Y, Emi K: A new method of quantifying angle measurements based on ultrasound biomicroscopy (in Japanese). Atarashii Ganka 1995, 12:957-960.
    • (1995) Atarashii Ganka , vol.12 , pp. 957-960
    • Ishikawa, H.1    Uji, Y.2    Emi, K.3
  • 14
    • 4243731016 scopus 로고    scopus 로고
    • Iris volume before and after pupillary dilation using ultrasound biomicroscopy
    • Ishikawa H, Ritch R, Hoh ST, et al.: Iris volume before and after pupillary dilation using ultrasound biomicroscopy [abstract] Invest Ophthalmol Vis Sci 1997, 38(suppl):S825.
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , Issue.SUPPL.
    • Ishikawa, H.1    Ritch, R.2    Hoh, S.T.3
  • 15
    • 0032189292 scopus 로고    scopus 로고
    • High-frequency Doppler ultrasound examination of blood flow in the anterior segment of the eye
    • Pavlin CJ, Christopher DA, Burns PN, et at: High-frequency Doppler ultrasound examination of blood flow in the anterior segment of the eye. Am J Ophthalmol 1998, 126:597-600.
    • (1998) Am J Ophthalmol , vol.126 , pp. 597-600
    • Pavlin, C.J.1    Christopher, D.A.2    Burns, P.N.3
  • 17
    • 0032033474 scopus 로고    scopus 로고
    • Imaging and spectrum analysis of contrast agents in the in vivo rabbit eye using very-high-frequency ultrasound
    • Deng CX, Lizzi FL, Silverman RH, et al.: Imaging and spectrum analysis of contrast agents in the in vivo rabbit eye using very-high-frequency ultrasound. Ultrasound Med Biol 1998, 24:383-394.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 383-394
    • Deng, C.X.1    Lizzi, F.L.2    Silverman, R.H.3
  • 18
    • 0031079960 scopus 로고    scopus 로고
    • Improved system for sonographic imaging and biometry of the cornea
    • Silverman RH, Reinstein DZ, Raevsky T, et al.: Improved system for sonographic imaging and biometry of the cornea. J Ultrasound Med 1997, 16: 117-124.
    • (1997) J Ultrasound Med , vol.16 , pp. 117-124
    • Silverman, R.H.1    Reinstein, D.Z.2    Raevsky, T.3
  • 19
    • 0033504309 scopus 로고    scopus 로고
    • Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: Anatomic diagnosis in lamellar surgery
    • Reinstein DZ, Silverman RH, Sutton HF, et al.: Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: anatomic diagnosis in lamellar surgery. Ophthalmology 1999, 106:474-482. Shows that very high frequency ultrasound is capable of performing pachymetric mapping of the cornea after automated lamellar keratoplasty and uncomplicated laser in situ keratomileusis with 2-μm precision.
    • (1999) Ophthalmology , vol.106 , pp. 474-482
    • Reinstein, D.Z.1    Silverman, R.H.2    Sutton, H.F.3
  • 20
    • 0031697286 scopus 로고    scopus 로고
    • The shape of Bowman's layer in the human cornea
    • Patel S, Reinstein DZ, Silverman RH, et al.: The shape of Bowman's layer in the human cornea. J Refract Surg 1998, 14:636-640.
    • (1998) J Refract Surg , vol.14 , pp. 636-640
    • Patel, S.1    Reinstein, D.Z.2    Silverman, R.H.3
  • 21
    • 0031957535 scopus 로고    scopus 로고
    • Correlation of high-frequency ultrasound backscatter with tumor microstructure in iris melanoma
    • Ursea R, Coleman DJ, Silverman RH, et al.: Correlation of high-frequency ultrasound backscatter with tumor microstructure in iris melanoma. Ophthalmology 1998, 105:906-912.
    • (1998) Ophthalmology , vol.105 , pp. 906-912
    • Ursea, R.1    Coleman, D.J.2    Silverman, R.H.3
  • 22
    • 0031938398 scopus 로고    scopus 로고
    • Three-dimensional ultrasound imaging: Clinical applications
    • Cusumano A, Coleman DJ, Silverman RH, et al.: Three-dimensional ultrasound imaging: clinical applications. Ophthalmology 1998, 105:300-306.
    • (1998) Ophthalmology , vol.105 , pp. 300-306
    • Cusumano, A.1    Coleman, D.J.2    Silverman, R.H.3
  • 23
    • 0033008475 scopus 로고    scopus 로고
    • High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye
    • Silverman RH, Kruse DE, Coleman DJ, et al.: High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye. Invest Ophthatmol Vis Sci 1999, 40:1373-1381. A new technology capable of visualizing vessels with luminal diameters as small as 40 μm and measuring blood flow velocity as low as 0.6 mm/s in the anterior segment.
    • (1999) Invest Ophthatmol Vis Sci , vol.40 , pp. 1373-1381
    • Silverman, R.H.1    Kruse, D.E.2    Coleman, D.J.3
  • 24
    • 0032926858 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic measurement of development of anterior chamber angle
    • Kobayashi H, Ono H, Kiryu J, et al.: Ultrasound biomicroscopic measurement of development of anterior chamber angle. Br J Ophthalmol 1999, 83:559-562. Presents the finding that anterior segment parameters on UBM images show linear increases in relation to logarithm of age.
    • (1999) Br J Ophthalmol , vol.83 , pp. 559-562
    • Kobayashi, H.1    Ono, H.2    Kiryu, J.3
  • 25
    • 0032470697 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma
    • Marchini G, Pagliarusco A, Toscano A, et al.: Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. Ophthalmology 1998, 105:2091-2098.
    • (1998) Ophthalmology , vol.105 , pp. 2091-2098
    • Marchini, G.1    Pagliarusco, A.2    Toscano, A.3
  • 26
    • 0032470975 scopus 로고    scopus 로고
    • Age and increased incidence of "forward bowing" of the iris in normal eyes
    • Ochiai H, Chihara E, Chuman H, et al.: Age and increased incidence of "forward bowing" of the iris in normal eyes. J Glaucoma 1998, 7:408-412.
    • (1998) J Glaucoma , vol.7 , pp. 408-412
    • Ochiai, H.1    Chihara, E.2    Chuman, H.3
  • 27
    • 0032925710 scopus 로고    scopus 로고
    • Pilocarpine induces an increase in the anterior chamber angular width in eyes with narrow angles
    • Kobayashi H, Kobayashi K, Kiryu J, et al.: Pilocarpine induces an increase in the anterior chamber angular width in eyes with narrow angles. Br J Ophthalmol 1999, 83:553-558.
    • (1999) Br J Ophthalmol , vol.83 , pp. 553-558
    • Kobayashi, H.1    Kobayashi, K.2    Kiryu, J.3
  • 28
    • 0032865440 scopus 로고    scopus 로고
    • Effects of 0.2% brimonidine on ocular anterior structures
    • Marchini G, Babighian S, Tosi R, et al.: Effects of 0.2% brimonidine on ocular anterior structures. J Ocul Pharmacol Ther 1999, 15:337-344. Shows that 0.2% brimonidine reduces the iris thickness with an increase in posterior chamber depth and in iris-ciliary process distance but with no changes in anterior chamber depth or chamber angle width.
    • (1999) J Ocul Pharmacol Ther , vol.15 , pp. 337-344
    • Marchini, G.1    Babighian, S.2    Tosi, R.3
  • 29
    • 0029593274 scopus 로고
    • An ultrasound biomicroscopic study of filtering blebs after mitomycin C trabeculectomy
    • Yamamoto T, Sakuma T, Kitazawa Y: An ultrasound biomicroscopic study of filtering blebs after mitomycin C trabeculectomy. Ophthalmology 1995, 102: 1770-1776.
    • (1995) Ophthalmology , vol.102 , pp. 1770-1776
    • Yamamoto, T.1    Sakuma, T.2    Kitazawa, Y.3
  • 30
    • 0029792205 scopus 로고    scopus 로고
    • The use of ultrasound biomicroscopy following trabeculectomy
    • McWhae JA, Crichton AC: The use of ultrasound biomicroscopy following trabeculectomy. Can J Ophthalmol 1996, 31:187-191.
    • (1996) Can J Ophthalmol , vol.31 , pp. 187-191
    • McWhae, J.A.1    Crichton, A.C.2
  • 31
    • 0031684920 scopus 로고    scopus 로고
    • Ultrasound-biomicroscopic evaluation of filtering blebs after laser suture lysis trabeculectomy
    • Avitabile T, Russo V, Uva MG, et al.: Ultrasound-biomicroscopic evaluation of filtering blebs after laser suture lysis trabeculectomy. Ophthalmologica 1998, 212(suppl 1):17-21.
    • (1998) Ophthalmologica , vol.212 , Issue.SUPPL. 1 , pp. 17-21
    • Avitabile, T.1    Russo, V.2    Uva, M.G.3
  • 32
    • 0029900125 scopus 로고    scopus 로고
    • Increase in iris-lens contact after laser iridotomy for pupillary block angle closure
    • Caronia RM, Liebmann JM, Stegman Z, et al.: Increase in iris-lens contact after laser iridotomy for pupillary block angle closure. Am J Ophthalmol 1996, 122:53-57.
    • (1996) Am J Ophthalmol , vol.122 , pp. 53-57
    • Caronia, R.M.1    Liebmann, J.M.2    Stegman, Z.3
  • 33
    • 0029608814 scopus 로고
    • Ultrasound biomicroscopy and corneal endothelium in Nd:YAG-laser iridotomy
    • Marraffa M, Marchini G, Pagliarusco A, et al.: Ultrasound biomicroscopy and corneal endothelium in Nd:YAG-laser iridotomy. Ophthalmic Surg Lasers 1995, 26:519-523.
    • (1995) Ophthalmic Surg Lasers , vol.26 , pp. 519-523
    • Marraffa, M.1    Marchini, G.2    Pagliarusco, A.3
  • 34
    • 0031941892 scopus 로고    scopus 로고
    • An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant
    • Chiou AG, Mermoud A, Underdahl JP, et al.: An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant. Ophthalmology 1998, 105:746-750.
    • (1998) Ophthalmology , vol.105 , pp. 746-750
    • Chiou, A.G.1    Mermoud, A.2    Underdahl, J.P.3
  • 35
    • 0030067504 scopus 로고    scopus 로고
    • Location of the iris insertion in pigment dispersion syndrome
    • Sokol J, Stegman Z, Liebmann JM, et al.: Location of the iris insertion in pigment dispersion syndrome. Ophthalmology 1996, 103:289-293.
    • (1996) Ophthalmology , vol.103 , pp. 289-293
    • Sokol, J.1    Stegman, Z.2    Liebmann, J.M.3
  • 36
    • 0029977646 scopus 로고    scopus 로고
    • Reduced trabecular meshwork height in juvenile primary open-angle glaucoma
    • Stegman Z, Sokol J, Liebmann JM, et al.: Reduced trabecular meshwork height in juvenile primary open-angle glaucoma. Arch Ophthalmol 1996, 114: 660-663.
    • (1996) Arch Ophthalmol , vol.114 , pp. 660-663
    • Stegman, Z.1    Sokol, J.2    Liebmann, J.M.3
  • 37
    • 0032908802 scopus 로고    scopus 로고
    • Ultrasound biomicroscopical study of the irido-corneal angle in dominant juvenile open-angle glaucoma, in POAG, and in normal eyes
    • Urbak SF: Ultrasound biomicroscopical study of the irido-corneal angle in dominant juvenile open-angle glaucoma, in POAG, and in normal eyes. Acta Ophthalmol Scand 1999, 77:160-164.
    • (1999) Acta Ophthalmol Scand , vol.77 , pp. 160-164
    • Urbak, S.F.1
  • 38
    • 0032160436 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy in the diagnosis and management of anterior segment tumors
    • Reminick LR, Finger PT, Ritch R, et al.: Ultrasound biomicroscopy in the diagnosis and management of anterior segment tumors. J Am Optom Assoc 1998, 69:575-582.
    • (1998) J Am Optom Assoc , vol.69 , pp. 575-582
    • Reminick, L.R.1    Finger, P.T.2    Ritch, R.3
  • 39
    • 0032408084 scopus 로고    scopus 로고
    • Anterior segment implantation cysts. Ultrasound biomicroscopy with histopathologic correlation
    • Marigo FA, Finger PT, McCormick SA, et al.: Anterior segment implantation cysts. Ultrasound biomicroscopy with histopathologic correlation. Arch Ophthalmol 1998, 116:1569-1575. Describes six eyes with anterior segment implantation cysts in a comparison of UBM images with size measurement to the histopathologic findings.
    • (1998) Arch Ophthalmol , vol.116 , pp. 1569-1575
    • Marigo, F.A.1    Finger, P.T.2    McCormick, S.A.3
  • 40
    • 0031715680 scopus 로고    scopus 로고
    • Keratoconus staging with ultrasound biomicroscopy
    • Avitabile T, Marano F, Castiglíone F, et al.: Keratoconus staging with ultrasound biomicroscopy. Ophthalmologica 1998, 212(suppl 1):10-12.
    • (1998) Ophthalmologica , vol.212 , Issue.SUPPL. 1 , pp. 10-12
    • Avitabile, T.1    Marano, F.2    Castiglíone, F.3
  • 41
    • 0029970737 scopus 로고    scopus 로고
    • Ciliary body enlargement and cyst formation in uveitis
    • Gentile RC, Liebmann JM, Tello C, et al.: Ciliary body enlargement and cyst formation in uveitis. Br J Ophthalmol 1996, 80:895-899.
    • (1996) Br J Ophthalmol , vol.80 , pp. 895-899
    • Gentile, R.C.1    Liebmann, J.M.2    Tello, C.3
  • 42
    • 0032076196 scopus 로고    scopus 로고
    • Serous detachment of the ciliary body in Harada disease
    • Maruyama Y, Kimura Y, Kishi S, et al.: Serous detachment of the ciliary body in Harada disease. Am J Ophthalmol 1998, 125:666-672.
    • (1998) Am J Ophthalmol , vol.125 , pp. 666-672
    • Maruyama, Y.1    Kimura, Y.2    Kishi, S.3
  • 43
    • 0031659269 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic imaging of posterior chamber phakic intraocular lens
    • Trindade F, Pereira F, Cronemberger S: Ultrasound biomicroscopic imaging of posterior chamber phakic intraocular lens. J Refract Surg 1998, 14:497-503.
    • (1998) J Refract Surg , vol.14 , pp. 497-503
    • Trindade, F.1    Pereira, F.2    Cronemberger, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.