메뉴 건너뛰기




Volumn 32, Issue 3, 2011, Pages 428-432

Assessment of electrode placement and audiological outcomes in bilateral cochlear implantation

Author keywords

Cochlear implants; Consonant noun consonant; Hearing in noise; Scala tympani; Scale vestibule

Indexed keywords

ADULT; AGED; ARTICLE; AUDIOMETRY; COCHLEA PROSTHESIS; FEMALE; HEARING LOSS; HUMAN; IMPLANTATION; MALE; METHODOLOGY; MIDDLE AGED; SCALA TYMPANI; TEMPORAL BONE; TREATMENT OUTCOME;

EID: 79953110890     PISSN: 15317129     EISSN: 15374505     Source Type: Journal    
DOI: 10.1097/MAO.0b013e3182096dc2     Document Type: Article
Times cited : (62)

References (16)
  • 1
    • 0037960732 scopus 로고    scopus 로고
    • Choice of ear for cochlear implantation: The effect of history and residual hearing on predicted postoperative performance
    • Friedland DR, Venick HS, Niparko JK. Choice of ear for cochlear implantation: the effect of history and residual hearing on predicted postoperative performance. Otol Neurotol 2003;24:582-9. (Pubitemid 36886271)
    • (2003) Otology and Neurotology , vol.24 , Issue.4 , pp. 582-589
    • Friedland, D.R.1    Venick, H.S.2    Niparko, J.K.3
  • 2
    • 0029127502 scopus 로고
    • Preoperative predictors of outcomes from cochlear implantation in adults: Performance and quality of life
    • Summerfield AQ, Marshall DH. Preoperative predictors of outcomes from cochlear implantation in adults: performance and quality of life. Ann Otol Rhinol Laryngol 1995;166:105-8.
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.166 , pp. 105-108
    • Summerfield, A.Q.1    Marshall, D.H.2
  • 3
    • 0029154157 scopus 로고
    • Prognostic indicators of speech recognition performance in adult cochlear implant users
    • Shipp DB, Nedzelski JM. Prognostic indicators of speech recognition performance in adult cochlear implant users. Ann Otol Rhinol Laryngol 1995;166:194-6.
    • (1995) Ann. Otol. Rhinol. Laryngol. , vol.166 , pp. 194-196
    • Shipp, D.B.1    Nedzelski, J.M.2
  • 5
    • 0033491520 scopus 로고    scopus 로고
    • Residual speech recognition and cochlear implant performance: Effects of implantation criteria
    • Rubinstein JT, Parkinson WS, Tyler RS, et al. Residual speech recognition and cochlear implant performance: effects of implantation criteria. Am J Otol 1999;20:445-52. (Pubitemid 30117036)
    • (1999) American Journal of Otology , vol.20 , Issue.4 , pp. 445-452
    • Rubinstein, J.T.1    Parkinson, W.S.2    Tyler, R.S.3    Gantz, B.J.4
  • 6
    • 0023682401 scopus 로고
    • Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills
    • Tong YC, Busby PA, Clark GM. Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills. J Acoust Soc Am 1988;84:951-62.
    • (1988) J. Acoust Soc. Am. , vol.84 , pp. 951-962
    • Tong, Y.C.1    Busby, P.A.2    Clark, G.M.3
  • 8
    • 24944553958 scopus 로고    scopus 로고
    • Speech perception with mono- and quadrupolar electrode configurations: A crossover study
    • DOI 10.1097/01.mao.0000185060.74339.9d
    • Mens LH, Berenstein CK. Speech perception with mono-and quadrupolar electrode configurations: a crossover study. Otol Neurotol 2005;26:957-64. (Pubitemid 41330712)
    • (2005) Otology and Neurotology , vol.26 , Issue.5 , pp. 957-964
    • Mens, L.H.M.1    Berenstein, C.K.2
  • 10
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM. Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation. Hear Res 1993;66:108-22.
    • (1993) Hear Res. , vol.66 , pp. 108-122
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 12
    • 34247640719 scopus 로고    scopus 로고
    • Quality control after insertion of the nucleus contour and contour advance electrode in adults
    • DOI 10.1097/AUD.0b013e318031542e, PII 0000344620070400100019
    • Aschendorff A, Kromeier J, Klenzer T, et al. Quality control after insertion of the Nucleus Contour and Contour Advance electrode in adults. Ear Hear 2007;28:75S-9. (Pubitemid 46673666)
    • (2007) Ear and Hearing , vol.28 , Issue.SUPPL. 2
    • Aschendorff, A.1    Kromeier, J.2    Klenzner, T.3    Laszig, R.4
  • 13
    • 59849092327 scopus 로고    scopus 로고
    • Role of electrode placement as a contributor to variability in cochlear implant outcomes
    • Finley CC, Holden TA, Holden LK, et al. Role of electrode placement as a contributor to variability in cochlear implant outcomes. Otol Neurotol 2008;29:920-8.
    • (2008) Otol. Neurotol , vol.29 , pp. 920-928
    • Finley, C.C.1    Holden, T.A.2    Holden, L.K.3
  • 15
    • 78349299387 scopus 로고    scopus 로고
    • Anatomic verification of a novel, non-rigid registration method for precise intrascalar localization of cochlear implant electrodes in adult human temporal bones using portable computerized tomography
    • Schuman T, Noble J, Wright G, Wanna G, Dawant B, Labadie R. Anatomic verification of a novel, non-rigid registration method for precise intrascalar localization of cochlear implant electrodes in adult human temporal bones using portable computerized tomography. Laryngoscope 2010;120:2277-83.
    • (2010) Laryngoscope , vol.120 , pp. 2277-2283
    • Schuman, T.1    Noble, J.2    Wright, G.3    Wanna, G.4    Dawant, B.5    Labadie, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.