메뉴 건너뛰기




Volumn 6, Issue 1, 2011, Pages

Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BRAIN TUMOR; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; HEAD AND NECK CANCER; INTENSITY MODULATED RADIATION THERAPY; LIVER CANCER; PRACTICE GUIDELINE; PROSTATE CANCER; QUALITY CONTROL; RADIATION DOSE DISTRIBUTION; STATISTICAL ANALYSIS; TREATMENT PLANNING; CALIBRATION; CARCINOMA; COMPUTER ASSISTED RADIOTHERAPY; EVALUATION; HEAD AND NECK TUMOR; HEALTH CARE QUALITY; HUMAN; IMAGE QUALITY; MALE; METHODOLOGY; PROSTATE TUMOR; RADIATION DOSE; RADIOMETRY; STANDARD; STATISTICS;

EID: 79953102210     PISSN: None     EISSN: 1748717X     Source Type: Journal    
DOI: 10.1186/1748-717X-6-27     Document Type: Article
Times cited : (19)

References (37)
  • 1
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: current status and issues of interest
    • 10.1016/S0360-3016(01)01749-7, 11704310, Intensity Modulated Radiation Therapy Collaborative Working Group
    • Intensity Modulated Radiation Therapy Collaborative Working Group Intensity-modulated radiotherapy: current status and issues of interest. Int J Radiat Oncol Biol Phys 2001, 51:880-914. 10.1016/S0360-3016(01)01749-7, 11704310, Intensity Modulated Radiation Therapy Collaborative Working Group.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 880-914
  • 2
    • 1542299570 scopus 로고    scopus 로고
    • Sparing of the penile bulb and proximal penile structures with intensity-modulated radiation therapy for prostate cancer
    • 10.1259/bjr/37893924, 15010385
    • Kao J, Turian J, Meyers A, Hamilton RJ, Smith B, Vijayakumar S, Jani AB. Sparing of the penile bulb and proximal penile structures with intensity-modulated radiation therapy for prostate cancer. Br J Radiol 2004, 77:129-136. 10.1259/bjr/37893924, 15010385.
    • (2004) Br J Radiol , vol.77 , pp. 129-136
    • Kao, J.1    Turian, J.2    Meyers, A.3    Hamilton, R.J.4    Smith, B.5    Vijayakumar, S.6    Jani, A.B.7
  • 3
    • 21244439018 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy after hysterectomy: comparison with conventional treatment and sensitivity of the normal-tissue-sparing effect to margin size
    • 10.1016/j.ijrobp.2004.12.029, 15990017
    • Ahamad A, D'Souza W, Salehpour M, Iyer R, Tucker SL, Jhingran A, Eifel PJ. Intensity-modulated radiation therapy after hysterectomy: comparison with conventional treatment and sensitivity of the normal-tissue-sparing effect to margin size. Int J Radiat Oncol Biol Phys 2005, 62:1117-1124. 10.1016/j.ijrobp.2004.12.029, 15990017.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1117-1124
    • Ahamad, A.1    D'Souza, W.2    Salehpour, M.3    Iyer, R.4    Tucker, S.L.5    Jhingran, A.6    Eifel, P.J.7
  • 4
    • 0034307220 scopus 로고    scopus 로고
    • Three dimension intensity modulated radiotherapy in the treatment of nasopharyngeal carcinoma: The University of California - San Francisco experience
    • 10.1016/S0360-3016(00)00702-1, 11020568
    • Sultanem K, Shu HK, Xia P, Akazawa C, Quivey JM, Verhey LJ, Fu KK. Three dimension intensity modulated radiotherapy in the treatment of nasopharyngeal carcinoma: The University of California - San Francisco experience. Int J Radiat Oncol Biol Phys 2000, 48:711-722. 10.1016/S0360-3016(00)00702-1, 11020568.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 711-722
    • Sultanem, K.1    Shu, H.K.2    Xia, P.3    Akazawa, C.4    Quivey, J.M.5    Verhey, L.J.6    Fu, K.K.7
  • 6
    • 14844309346 scopus 로고    scopus 로고
    • Dosimetric advantages of IMRT simultaneous integrated boost for high-risk prostate cancer
    • 10.1016/j.ijrobp.2004.11.034, 15752907
    • Li XA, Wang JZ, Jursinic PA, Lawton CA, Wang D. Dosimetric advantages of IMRT simultaneous integrated boost for high-risk prostate cancer. Int J Radiat Oncol Biol Phys 2005, 61:1251-1257. 10.1016/j.ijrobp.2004.11.034, 15752907.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1251-1257
    • Li, X.A.1    Wang, J.Z.2    Jursinic, P.A.3    Lawton, C.A.4    Wang, D.5
  • 8
    • 41749107380 scopus 로고    scopus 로고
    • Quality assurance of intensity modulated radiation therapy
    • 10.1016/j.ijrobp.2007.05.092, 18406906
    • Palta JR, Liu C, Li JG. Quality assurance of intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys 2008, 71:S108-S112. 10.1016/j.ijrobp.2007.05.092, 18406906.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71
    • Palta, J.R.1    Liu, C.2    Li, J.G.3
  • 9
    • 2542471344 scopus 로고    scopus 로고
    • Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer
    • 10.1016/j.radonc.2004.02.016, 15172148
    • Boehmer D, Bohsung J, Eichwurzel I, Moys A, Budach V. Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer. Radiother Oncol 2004, 71:319-325. 10.1016/j.radonc.2004.02.016, 15172148.
    • (2004) Radiother Oncol , vol.71 , pp. 319-325
    • Boehmer, D.1    Bohsung, J.2    Eichwurzel, I.3    Moys, A.4    Budach, V.5
  • 10
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    • 10.1118/1.1591194, 12945975
    • Ezzell GA, Galvin JM, Low D, Palta JR, Rosen I, Sharpe MB, Xia P, Xiao Y, Xing L, Yu CX. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee. Med Phys 2003, 30:2089-2115. 10.1118/1.1591194, 12945975.
    • (2003) Med Phys , vol.30 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3    Palta, J.R.4    Rosen, I.5    Sharpe, M.B.6    Xia, P.7    Xiao, Y.8    Xing, L.9    Yu, C.X.10
  • 11
    • 16444377303 scopus 로고    scopus 로고
    • Micro ionization-chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV
    • 10.1016/j.radonc.2005.04.011, 15967525
    • Doblado FS, Capote R, Rosello JV, Leal A, Lagares JI, Arrans R, Hartmann GH. Micro ionization-chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV. Radiother Oncol 2005, 75:342-348. 10.1016/j.radonc.2005.04.011, 15967525.
    • (2005) Radiother Oncol , vol.75 , pp. 342-348
    • Doblado, F.S.1    Capote, R.2    Rosello, J.V.3    Leal, A.4    Lagares, J.I.5    Arrans, R.6    Hartmann, G.H.7
  • 12
    • 79551660106 scopus 로고    scopus 로고
    • Guidelines for the verification of IMRT
    • Brussels, Belgium: ESTRO
    • Mijheer B, Georg D. Guidelines for the verification of IMRT. 2008, Brussels, Belgium: ESTRO.
    • (2008)
    • Mijheer, B.1    Georg, D.2
  • 14
    • 85024939309 scopus 로고    scopus 로고
    • Patient specific quality assurance for the delivery of intensity modulated radiotherapy
    • Agazaryan N, Solberg TD, Demarco JJ. Patient specific quality assurance for the delivery of intensity modulated radiotherapy. J Appl Clin Med Phys 2003, 4:453-461.
    • (2003) J Appl Clin Med Phys , vol.4 , pp. 453-461
    • Agazaryan, N.1    Solberg, T.D.2    Demarco, J.J.3
  • 15
  • 17
    • 0035021643 scopus 로고    scopus 로고
    • Dose verification for patients undergoing IMRT
    • 10.1016/S0958-3947(01)00059-0, 11444520
    • Ting JY, Davis LW. Dose verification for patients undergoing IMRT. Med Dosim 2001, 26:179-188. 10.1016/S0958-3947(01)00059-0, 11444520.
    • (2001) Med Dosim , vol.26 , pp. 179-188
    • Ting, J.Y.1    Davis, L.W.2
  • 19
    • 25644461233 scopus 로고    scopus 로고
    • Statical process control for radiotherapy quality assurance
    • 10.1118/1.2001209, 16266091
    • Pawlicki T, Whitaker M, Boyer AL. Statical process control for radiotherapy quality assurance. Med Phys 2005, 32:2777-2786. 10.1118/1.2001209, 16266091.
    • (2005) Med Phys , vol.32 , pp. 2777-2786
    • Pawlicki, T.1    Whitaker, M.2    Boyer, A.L.3
  • 20
    • 34247616145 scopus 로고    scopus 로고
    • Quality in radiation oncology
    • 10.1118/1.2727748, 17555234
    • Pawlicki T, Mundt AJ. Quality in radiation oncology. Med Phys 2007, 34:1529-1534. 10.1118/1.2727748, 17555234.
    • (2007) Med Phys , vol.34 , pp. 1529-1534
    • Pawlicki, T.1    Mundt, A.J.2
  • 21
    • 52949089003 scopus 로고    scopus 로고
    • Statistical process control for IMRT dosimetric verification
    • 10.1118/1.2975144, 18975688
    • Breen SL, Moseley DJ, Zhang B, Sharpe MB. Statistical process control for IMRT dosimetric verification. Med Phys 2008, 35:4417-4425. 10.1118/1.2975144, 18975688.
    • (2008) Med Phys , vol.35 , pp. 4417-4425
    • Breen, S.L.1    Moseley, D.J.2    Zhang, B.3    Sharpe, M.B.4
  • 22
    • 0141520680 scopus 로고    scopus 로고
    • Evaluation of the gamma dose distribution comparison method
    • 10.1118/1.1598711, 14528967
    • Low DA, Dempsey JF. Evaluation of the gamma dose distribution comparison method. Med Phys 2003, 30:2455-2464. 10.1118/1.1598711, 14528967.
    • (2003) Med Phys , vol.30 , pp. 2455-2464
    • Low, D.A.1    Dempsey, J.F.2
  • 24
    • 41749124562 scopus 로고    scopus 로고
    • Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials
    • 10.1016/j.ijrobp.2007.08.083, 2409281, 18406942
    • Ibbott GS, Followill DS, Molineu HA, Lowenstein JR, Alvarez PE, Roll JE. Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials. Int J Radiat Oncol Biol Phys 2008, 71:S71-S75. 10.1016/j.ijrobp.2007.08.083, 2409281, 18406942.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71
    • Ibbott, G.S.1    Followill, D.S.2    Molineu, H.A.3    Lowenstein, J.R.4    Alvarez, P.E.5    Roll, J.E.6
  • 25
    • 36749016150 scopus 로고    scopus 로고
    • Agreement criteria between excepted and measured field fluence in IMRT of head and neck cancer: The importance and use of the γ histograms statical analysis
    • Jeraj R, Keall PJ, Ostwald PM. Agreement criteria between excepted and measured field fluence in IMRT of head and neck cancer: The importance and use of the γ histograms statical analysis. Radiother Oncol 2007, 85:399-406.
    • (2007) Radiother Oncol , vol.85 , pp. 399-406
    • Jeraj, R.1    Keall, P.J.2    Ostwald, P.M.3
  • 26
    • 0031895424 scopus 로고    scopus 로고
    • A gradient inverse planning algorithm with dose volume constraints
    • 10.1118/1.598202, 9547499
    • Spirou SV, Chui CS. A gradient inverse planning algorithm with dose volume constraints. Med Phys 1998, 25:321-333. 10.1118/1.598202, 9547499.
    • (1998) Med Phys , vol.25 , pp. 321-333
    • Spirou, S.V.1    Chui, C.S.2
  • 27
    • 36049031951 scopus 로고    scopus 로고
    • IMRT using simultaneously integrated boost (SIB) in head and neck cancer patients
    • 10.1186/1748-717X-1-7, 1459185, 16722599
    • Studer G, Huguenin PU, Davis JB, Kunz G, Lütolf UM, Glanzmann C. IMRT using simultaneously integrated boost (SIB) in head and neck cancer patients. Radiation Oncology 2006, 1:7-21. 10.1186/1748-717X-1-7, 1459185, 16722599.
    • (2006) Radiation Oncology , vol.1 , pp. 7-21
    • Studer, G.1    Huguenin, P.U.2    Davis, J.B.3    Kunz, G.4    Lütolf, U.M.5    Glanzmann, C.6
  • 28
    • 39049096779 scopus 로고    scopus 로고
    • What is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT
    • 10.1186/1748-717X-2-42, 2234418, 18036217
    • Giorgia N, Antonella F, Eugenio V, Alessandro C, Filippo A, Luca C. What is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT. Radiation Oncology 2007, 2:42-54. 10.1186/1748-717X-2-42, 2234418, 18036217.
    • (2007) Radiation Oncology , vol.2 , pp. 42-54
    • Giorgia, N.1    Antonella, F.2    Eugenio, V.3    Alessandro, C.4    Filippo, A.5    Luca, C.6
  • 29
    • 47149103824 scopus 로고    scopus 로고
    • Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy
    • 10.1016/j.ijrobp.2008.04.014, 18513883
    • Jang SY, Liu HH, Mohan R. Underestimation of low-dose radiation in treatment planning of intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 2008, 71:1537-1546. 10.1016/j.ijrobp.2008.04.014, 18513883.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1537-1546
    • Jang, S.Y.1    Liu, H.H.2    Mohan, R.3
  • 30
    • 37549052531 scopus 로고    scopus 로고
    • Non-equilibrium radiation dosimetry
    • 10.1118/1.2815356, 18293576, Small fields
    • Das IJ, Ding GX, Ahnesjo A, . Small fields Non-equilibrium radiation dosimetry. Med Phys 2008, 35:206-213. 10.1118/1.2815356, 18293576, Small fields.
    • (2008) Med Phys , vol.35 , pp. 206-213
    • Das, I.J.1    Ding, G.X.2    Ahnesjo, A.3
  • 31
    • 0034036227 scopus 로고    scopus 로고
    • Dose calculation and verification of intensity modulation generated by dynamic multileaf collimators
    • 10.1118/1.598960, 10841398
    • Papatheodorou S, Rosenwald JC, Zefkili S, Murillo MC, Drouard J, Gaboriaud G. Dose calculation and verification of intensity modulation generated by dynamic multileaf collimators. Med Phys 2000, 27:960-971. 10.1118/1.598960, 10841398.
    • (2000) Med Phys , vol.27 , pp. 960-971
    • Papatheodorou, S.1    Rosenwald, J.C.2    Zefkili, S.3    Murillo, M.C.4    Drouard, J.5    Gaboriaud, G.6
  • 32
    • 0032911422 scopus 로고    scopus 로고
    • Dosimetric verification of a commercial inverse treatment planning system
    • 10.1088/0031-9155/44/2/013, 10070795
    • Xing L, Curran B, Hill R, Holmes T, Ma L, Forster KM, Boyer AL. Dosimetric verification of a commercial inverse treatment planning system. Phys Med Biol 1999, 44:463-478. 10.1088/0031-9155/44/2/013, 10070795.
    • (1999) Phys Med Biol , vol.44 , pp. 463-478
    • Xing, L.1    Curran, B.2    Hill, R.3    Holmes, T.4    Ma, L.5    Forster, K.M.6    Boyer, A.L.7
  • 33
    • 4644300643 scopus 로고    scopus 로고
    • An EGSnrc Monte Carlo study of the microionization-chamber for reference dosimetry of narrow irregular IMRT beamlets
    • 10.1118/1.1767691, 15487721
    • Capote R, Sanchez-Doblado F, Leal A, Lagares JL, Arrans R, Hartman GH. An EGSnrc Monte Carlo study of the microionization-chamber for reference dosimetry of narrow irregular IMRT beamlets. Med Phys 2004, 31:2416-2422. 10.1118/1.1767691, 15487721.
    • (2004) Med Phys , vol.31 , pp. 2416-2422
    • Capote, R.1    Sanchez-Doblado, F.2    Leal, A.3    Lagares, J.L.4    Arrans, R.5    Hartman, G.H.6
  • 34
    • 0035055467 scopus 로고    scopus 로고
    • The MLC tongue-and-groove effect on IMRT dose distributions
    • 10.1088/0031-9155/46/4/310, 11324950
    • Deng J, Pawlicki T, Chen Y, Li J, Jiang SB, Ma CM. The MLC tongue-and-groove effect on IMRT dose distributions. Phys Med Biol 2001, 46:1039-1060. 10.1088/0031-9155/46/4/310, 11324950.
    • (2001) Phys Med Biol , vol.46 , pp. 1039-1060
    • Deng, J.1    Pawlicki, T.2    Chen, Y.3    Li, J.4    Jiang, S.B.5    Ma, C.M.6
  • 35
    • 77953492402 scopus 로고    scopus 로고
    • Uncertainties in IMRT dosimetry
    • 10.1118/1.3413997, 20632560
    • Li JS, Lin T, Chen L, Price RA, Ma CM. Uncertainties in IMRT dosimetry. Med Phys 2010, 37:2491-2500. 10.1118/1.3413997, 20632560.
    • (2010) Med Phys , vol.37 , pp. 2491-2500
    • Li, J.S.1    Lin, T.2    Chen, L.3    Price, R.A.4    Ma, C.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.