Volumn 26, Issue 2, 2001, Pages 205-213

Dose verification for patients undergoing IMRT

Author keywords

IMRT; Patient dose verification; Quality assurance; Radiotherapy

Indexed keywords

ARTICLE; CLINICAL PRACTICE; COLLIMATOR; COMPUTER; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER PROGRAM; ELECTRONICS; FILM; HUMAN; INTENSITY MODULATED RADIATION THERAPY; INVERSE PLANNING; IONIZATION CHAMBER; MEASUREMENT; MULTILEAF COLLIMATOR; PATIENT; PHANTOM; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RADIOTHERAPY; TREATMENT PLANNING; TUMOR VOLUME; VOLUMETRY;

EID: 0035021643     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(01)00059-0     Document Type: Article
Times cited : (29)

References (27)
  • 2
    • 0004921272 scopus 로고    scopus 로고
    • Keller-Reichenbecher, M.A.; Bortfeld, T.; Levegrun, S.; et al. Intensity modulation with the 'step and shoot' technique using a commercial MLC: A planning study. Int. J. Radiat. Oncol. Biol. Phys.451315-24; 1999.
  • 6
    • 0031696390 scopus 로고    scopus 로고
    • Generation of discrete beam-intensity modulation by dynamic multileaf collimation under minimum leaf separation constraints
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2521-2538
    • Convery, D.J.1    Webb, S.2
  • 7
    • 0028144837 scopus 로고
    • Generation of arbitrary intensity profiles by dynamic jaws or multi-leaf collimators
    • (1994) Med. Phys. , vol.21 , pp. 1031-1041
    • Spirou, S.1    Chui, C.S.2
  • 9
    • 0030986682 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy by means of static tomotherapy-A planning and verification study
    • (1997) Med. Phys. , vol.24 , pp. 827-836
    • Oldham, M.1    Webb, S.2
  • 11
    • 0031868367 scopus 로고    scopus 로고
    • Multi-leaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments
    • (1998) Med. Phys. , vol.25 , pp. 1424-1434
    • Xia, P.1    Verhey, L.J.2
  • 12
  • 18
    • 0032794120 scopus 로고    scopus 로고
    • Temporal resolution requirements for intensity modulated radiation therapy delivered by multileaf collimators
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1581-1596
    • Budgett, G.J.1
  • 23
    • 0004921274 scopus 로고    scopus 로고
    • Ma, L.; Chang, W.; Lau-Chin, M.; Tate, E.M.; Boyer, A.L. Using static MLC fields to replace partial transmission cerrobend blocks in treatment planning of rectal carcinoma cases. Med. Dosim.23 264-6; 1998.
  • 26
    • 0034237722 scopus 로고    scopus 로고
    • Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy
    • (2000) Radiat Oncol , vol.56 , pp. 97-108
    • Xing, L.1    Lin, Z.2    Donalson, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.