메뉴 건너뛰기




Volumn 153, Issue 2, 2011, Pages 369-372

One-step sensing lead in surface waters with screen printed electrode

Author keywords

Internal standard; One step electrochemical detection; Pb detection; Surface water

Indexed keywords

CALIBRATION CONSTANTS; ELECTROCHEMICAL DETECTION; ICP-AES; INTERNAL STANDARDIZATION; INTERNAL STANDARDS; LEAD DETECTION; LINEAR RANGE; PB DETECTION; PLATING SOLUTIONS; PPB LEVELS; SCREEN PRINTED ELECTRODES; SCREEN-PRINTED CARBON ELECTRODES; SINGLE-STEP;

EID: 79953025475     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.10.049     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 34848834579 scopus 로고    scopus 로고
    • Bismuth-coated diamond-like carbon microelectrodes for heavy metals determination
    • DOI 10.1016/j.snb.2007.07.031, PII S0925400507004856, Eurosensors XX The 20th European Conference on Solid-State Transducers
    • V. Rehacek, I. Hotovy, and M. Vojs Bismuth-coated diamond-like carbon microelectrodes for heavy metals determination Sens. Actuators B 127 2007 193 197 (Pubitemid 47503723)
    • (2007) Sensors and Actuators, B: Chemical , vol.127 , Issue.1 , pp. 193-197
    • Rehacek, V.1    Hotovy, I.2    Vojs, M.3
  • 3
    • 3242774357 scopus 로고    scopus 로고
    • Hazards of heavy metal contamination
    • DOI 10.1093/bmb/ldg032
    • L. Jarup Hazards of heavy metal contamination Br. Med. Bull. 68 2003 167 182 (Pubitemid 38248496)
    • (2003) British Medical Bulletin , vol.68 , pp. 167-182
    • Jarup, L.1
  • 4
    • 79953028908 scopus 로고    scopus 로고
    • European Council decision 2455/2001/EC
    • European Council decision 2455/2001/EC Off. J. L 331 2001
    • (2001) Off. J. L , vol.331
  • 5
    • 79953026427 scopus 로고    scopus 로고
    • European Council directive 98/83/EC
    • European Council directive 98/83/EC Off. J. L 330 1998
    • (1998) Off. J. , vol.L330
  • 6
    • 79953029457 scopus 로고    scopus 로고
    • http://www.dropsens.com, September 2010.
  • 7
    • 79953029782 scopus 로고    scopus 로고
    • http://www.g-e-m.com/Gem/index.html, September 2010.
  • 8
    • 77953027640 scopus 로고    scopus 로고
    • Tree-shaped paper strip for semiquantitative colorimetric detection of protein with self-calibration
    • W. Wang, W. Wu, W. Wang, and J.J. Zhu Tree-shaped paper strip for semiquantitative colorimetric detection of protein with self-calibration J. Chromatogr. A 1217 2010 3896 3899
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3896-3899
    • Wang, W.1    Wu, W.2    Wang, W.3    Zhu, J.J.4
  • 9
    • 78049523213 scopus 로고    scopus 로고
    • Paper disk on screen printed electrode for one-step sensing with an internal standard
    • S.N. Tan, L. Ge, and W. Wang Paper disk on screen printed electrode for one-step sensing with an internal standard Anal. Chem. 82 2010 8844 8847
    • (2010) Anal. Chem. , vol.82 , pp. 8844-8847
    • Tan, S.N.1    Ge, L.2    Wang, W.3
  • 10
    • 0034661524 scopus 로고    scopus 로고
    • Bismuth-coated carbon electrodes for anodic stripping voltammetry
    • DOI 10.1021/ac000108x
    • J. Wang, J. Lu, S. Hocevar, P. Farias, and B. Ogorevc Bismuth-coated carbon electrodes for anodic stripping voltammetry Anal. Chem. 72 2000 3218 3222 (Pubitemid 30482494)
    • (2000) Analytical Chemistry , vol.72 , Issue.14 , pp. 3218-3222
    • Wang, J.1    Lu, J.2    Hocevar, S.B.3    Farias, P.A.M.4    Ogorevc, B.5
  • 11
    • 75749113741 scopus 로고    scopus 로고
    • Diagnostics for the developing world: Microfluidic paper-based analytical devices
    • A.W. Martinez, S.T. Phillips, G.M. Whitesides, and E. Carrilho Diagnostics for the developing world: microfluidic paper-based analytical devices Anal. Chem. 82 2010 3 10
    • (2010) Anal. Chem. , vol.82 , pp. 3-10
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3    Carrilho, E.4
  • 13
    • 73149106173 scopus 로고    scopus 로고
    • Development and performance evaluation of ozone detection paper using azo dye orange. I: Effect of pH
    • Y.Y. Maruo, K. Akaoka, and J. Nakamura Development and performance evaluation of ozone detection paper using azo dye orange. I: Effect of pH Sens. Actuators B 143 2010 493 497
    • (2010) Sens. Actuators B , vol.143 , pp. 493-497
    • Maruo, Y.Y.1    Akaoka, K.2    Nakamura, J.3
  • 15
    • 77951651485 scopus 로고    scopus 로고
    • Heterogeneous films of ionotropic hydrogels fabricated from delivery templates of patterned paper
    • P.J. Bracher, M. Gupta, E.T. Mack, and G.M. Whitesides Heterogeneous films of ionotropic hydrogels fabricated from delivery templates of patterned paper ACS Appl. Mater. Interfaces 1 2009 1807 1812
    • (2009) ACS Appl. Mater. Interfaces , vol.1 , pp. 1807-1812
    • Bracher, P.J.1    Gupta, M.2    MacK, E.T.3    Whitesides, G.M.4
  • 18
    • 0023287497 scopus 로고
    • Square-wave anodic-stripping voltammetry at the mercury film electrode - Theoretical treatment
    • S.P. Kounaves, J.J. Oder, P. Chandresekhar, and J. Osteryoung Square-wave anodic-stripping voltammetry at the mercury film electrode - theoretical treatment Anal. Chem. 59 1987 386 389 (Pubitemid 17514720)
    • (1987) Analytical Chemistry , vol.59 , Issue.3 , pp. 386-389
    • Kounaves, S.P.1    O'Dea, J.J.2    Chandresekhar, P.3    Osteryoung Janet4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.