Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies

Author keywords

breast imaging; Cone beam CT; scatter correction

Indexed keywords

BREAST IMAGING; BREAST PHANTOM; CHEST WALL; CLINICAL STUDY; CONE BEAM CT; CUPPING ARTIFACTS; DIFFERENT SIZES; FLAT-PANEL DETECTORS; LOCAL SCATTERING; PHANTOM SIZES; PHANTOM STUDIES; PROJECTION IMAGE; RECONSTRUCTION ERROR; SCATTER CORRECTION; SCATTER-TO-PRIMARY RATIO; SCATTERED RADIATIONS; SCATTERING CORRECTIONS; SCATTERING IMAGE; SCATTERING PROFILES; SMOOTH CURVES; SPR METHOD;

EID: 79952975909     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: 10.3233/XST-2010-0280     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • DOI 10.1118/1.1461843
    • B. Chen and R. Ning, Cone-beam volume CT breast imaging: Feasibility study, Med Phys 29(5) (2002), 755-770. (Pubitemid 34525905)
    • (2002) Medical Physics , vol.29 , Issue.5 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 2
    • 0042377130 scopus 로고    scopus 로고
    • Realtime flatpanel detectorbased cone beam volume CT breast imaging: Phantom and specimen study
    • R. Ning, D. Conover, Y. Yu, L. Schiffhauer, X. Lu, J. Cullinan and A.E. Robinson, Realtime flatpanel detectorbased cone beam volume CT breast imaging: Phantom and specimen study, Proc. of SPIE 5030 (2003), 181-190.
    • (2003) Proc. of SPIE , vol.5030 , pp. 181-190
    • Ning, R.1    Conover, D.2    Yu, Y.3    Schiffhauer, L.4    Lu, X.5    Cullinan, J.6    Robinson, A.E.7
  • 3
    • 3042542737 scopus 로고    scopus 로고
    • Preliminary system characterization of flat-panel-detector-based cone-beam CT for breast imaging
    • R. Ning, Y. Yu, D. Conover, X. Lu, H. He, Z. Chen, L. Schiffhauer and J. Cullinan, Preliminary system characterization of flat-panel-detector-based cone-beam CT for breast imaging, Proc. of SPIE 5368 (2004), 292-303.
    • (2004) Proc. of SPIE , vol.5368 , pp. 292-303
    • Ning, R.1    Yu, Y.2    Conover, D.3    Lu, X.4    He, H.5    Chen, Z.6    Schiffhauer, L.7    Cullinan, J.8
  • 6
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • J.M. Boone, T.R. Nelson, K.K. Lindfors and J. Anthony Seibert, Dedicated Breast CT: Radiation Dose and Image Quality Evaluation, Radiology 221 (2001), 657-667. (Pubitemid 33101756)
    • (2001) Radiology , vol.221 , Issue.3 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 8
    • 0035053536 scopus 로고    scopus 로고
    • Effect of scattered radiation on image noise in cone beam CT
    • DOI 10.1118/1.1357457
    • M. Endo, T. Tsunoo, N. Nakamori and K. Yoshida, Effect of scattered radiation on image noise in cone beam CT, Med Phys 28(4) (2001), 469-474. (Pubitemid 32323298)
    • (2001) Medical Physics , vol.28 , Issue.4 , pp. 469-474
    • Endo, M.1    Tsunoo, T.2    Nakamori, N.3    Yoshida, K.4
  • 9
    • 0034871399 scopus 로고    scopus 로고
    • Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT
    • DOI 10.1117/12.430868
    • X. Tang, R. Ning, R. Yu and D. Conover, Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT, Proceedings of SPIE 4320 (2001), 851-860. (Pubitemid 32794545)
    • (2001) Proceedings of SPIE - The International Society for Optical Engineering , vol.4320 , pp. 851-860
    • Tang, X.1    Ning, R.2    Yu, R.3    Conover, D.4
  • 10
    • 25644435753 scopus 로고    scopus 로고
    • Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner
    • DOI 10.1118/1.1954908
    • L.C. Kwan, J.M. Boone and N. Shah, Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner, Med Phys 32 (2005), 2967-2975. (Pubitemid 41384094)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2967-2975
    • Kwan, A.L.C.1    Boone, J.M.2    Shah, N.3
  • 11
    • 0034111936 scopus 로고    scopus 로고
    • An edge spread technique for measurement of the scatter-to-primary ratio in mammography
    • DOI 10.1118/1.598950
    • V.N. Cooper III, J.M. Boone, J. Anthony Seibert and Claire J. Pellot-Barakat, An edge spread technique for measurement of the scattertoprimary ratio in mammography, Med Phys 27(5) (2000), 845-853. (Pubitemid 30349992)
    • (2000) Medical Physics , vol.27 , Issue.5 , pp. 845-853
    • Cooper III, V.N.1    Boone, J.M.2    Seibert, J.A.3    Pellot-Barakat, C.J.4
  • 12
    • 0021868276 scopus 로고
    • Scatter rejection by air gaps: An empirical model
    • DOI 10.1118/1.595690
    • J.A. Sorenson and J. Floch, Scatter rejection by air gaps: An empirical model, Med Phys 12 (1985), 308-316. (Pubitemid 15042816)
    • (1985) Medical Physics , vol.12 , Issue.3 , pp. 308-316
    • Sorenson, J.A.1    Floch, J.2
  • 13
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • U. Neitzel, Grids or air gaps for scatter reduction in digital radiography: A model calculation, Med Phys 19 (1992), 475-481.
    • (1992) Med Phys , vol.19 , pp. 475-481
    • Neitzel, U.1
  • 14
    • 0038372096 scopus 로고    scopus 로고
    • The value of scatter removal by a grid in full field digital mammography
    • DOI 10.1118/1.1584044
    • W.J.H. Veldkamp, M.A.O. Thijssen and N. Karssemijer, The value of scatter removal by a grid in full field digital mammography, Med Phys 30(7) (2003), 1712-1718. (Pubitemid 36885788)
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1712-1718
    • Veldkamp, W.J.H.1    Thijssen, M.A.O.2    Karssemeijer, N.3
  • 15
    • 0023212881 scopus 로고
    • Scatter estimation for a digital radiographic system using convolution filtering
    • DOI 10.1118/1.596126
    • L. Alan Love and R.A. Kruger, Scatter estimation for a digital radiographic system using convolution filtering, Med Phys 14 (1987), 178-185. (Pubitemid 17063679)
    • (1987) Medical Physics , vol.14 , Issue.2 , pp. 178-185
    • Love, L.A.1    Kruger, R.A.2
  • 16
    • 0023752571 scopus 로고
    • X-ray scatter removal by deconvolution
    • J.A. Seibert and J.M. Boone, X-ray scatter removal by deconvolution, Med Phys 15 (1988), 567-575.
    • (1988) Med Phys , vol.15 , pp. 567-575
    • Seibert, J.A.1    Boone, J.M.2
  • 18
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • DOI 10.1118/1.1711475
    • R. Ning and X. Tang, X-ray scatter correction algorithm for cone beam CT imaging, Med Phys 31 (2004), 1195-1202. (Pubitemid 38656792)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1195-1202
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 19
    • 33745349993 scopus 로고    scopus 로고
    • Scatter correction using beam stop array algorithm for cone-beam CT breast imaging
    • W. Cai, R. Ning and D. Conover, Scatter correction using beam stop array algorithm for cone-beam CT breast imaging, Proc. SPIE Vol. 6142, 61423E (2006).
    • (2006) Proc. SPIE , vol.6142
    • Cai, W.1    Ning, R.2    Conover, D.3
  • 20
    • 75749098740 scopus 로고    scopus 로고
    • Asimplifiedmethod of scatter correction using beamstoparray algorithmfor cone-beam computed tomography breast imaging
    • W.Cai, R.Ning andD.Conover, Asimplifiedmethod of scatter correction using beamstoparray algorithmfor cone-beam computed tomography breast imaging, Opt Eng 47(8) (2008), 097003.
    • (2008) Opt Eng , vol.47 , Issue.8 , pp. 097003
    • Cai, W.1    Ning, R.2    Conover, D.3
  • 21
    • 35148835331 scopus 로고    scopus 로고
    • Evaluation of a new breastshaped compensation filter for a newly built breast imaging system
    • W. Cai, R. Ning, Y. Zhang and D. Conover, Evaluation of a new breastshaped compensation filter for a newly built breast imaging system, Proc. SPIE Vol. 6510, 651039 (2007).
    • (2007) Proc. SPIE , vol.6510 , pp. 651039
    • Cai, W.1    Ning, R.2    Zhang, Y.3    Conover, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.