메뉴 건너뛰기




Volumn 6510, Issue PART 2, 2007, Pages

Evaluation of a new breast-shaped compensation filter for a newly built breast imaging system

Author keywords

Breast imaging; Compensation filter; Cone beam CT

Indexed keywords

BREAST IMAGING; BREAST PHANTOMS; COMPENSATION FILTERS;

EID: 35148835331     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.710167     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • B Chen and R Ning, "Cone-beam volume CT breast imaging: Feasibility study," Med. Phys. 29(5), 755-770 (2002)
    • (2002) Med. Phys , vol.29 , Issue.5 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 2
    • 0042377130 scopus 로고    scopus 로고
    • Real-time flat-panel detector-based cone beam volume CT breast imaging: Phantom and specimen study
    • R Ning, D Conover, Y Yu, L Schiffhauer, X Lu, J Cullinan and A E Robinson, "Real-time flat-panel detector-based cone beam volume CT breast imaging: phantom and specimen study," Proc. of SPIE, 5030, 181-190 (2003)
    • (2003) Proc. of SPIE , vol.5030 , pp. 181-190
    • Ning, R.1    Conover, D.2    Yu, Y.3    Schiffhauer, L.4    Lu, X.5    Cullinan, J.6    Robinson, A.E.7
  • 3
    • 3042542737 scopus 로고    scopus 로고
    • Preliminary system characterization of flat-panel-detector-based cone-beam CT for breast imaging
    • R Ning, Y Yu, D Conover, X Lu, H He, Z Chen, L Schiffhauer and J Cullinan, "Preliminary system characterization of flat-panel-detector-based cone-beam CT for breast imaging," Proc. of SPIE, 5368, 292-303 (2004)
    • (2004) Proc. of SPIE , vol.5368 , pp. 292-303
    • Ning, R.1    Yu, Y.2    Conover, D.3    Lu, X.4    He, H.5    Chen, Z.6    Schiffhauer, L.7    Cullinan, J.8
  • 4
    • 23844441970 scopus 로고    scopus 로고
    • Evaluation of flat panel detector cone beam CT breast imaging with different sizes of breast phantoms
    • R Ning, D Conover, X Lu, Y Zhang, Y Yu, L Schiffhauer and J Cullinan, "Evaluation of flat panel detector cone beam CT breast imaging with different sizes of breast phantoms," Proc. of SPIE, 5745, 626-636 (2005)
    • (2005) Proc. of SPIE , vol.5745 , pp. 626-636
    • Ning, R.1    Conover, D.2    Lu, X.3    Zhang, Y.4    Yu, Y.5    Schiffhauer, L.6    Cullinan, J.7
  • 6
    • 33645000127 scopus 로고    scopus 로고
    • Technique factors and their relationship to radiation dose in pendant geometry breast CT
    • JM Boone, ALC Kwan, J A Seibert, N Shah, K K Lindfors and T R Nelson, "Technique factors and their relationship to radiation dose in pendant geometry breast CT," Med. Phys. 32(12), 3767-3776 (2005)
    • (2005) Med. Phys , vol.32 , Issue.12 , pp. 3767-3776
    • Boone, J.M.1    Kwan, A.L.C.2    Seibert, J.A.3    Shah, N.4    Lindfors, K.K.5    Nelson, T.R.6
  • 7
    • 0031802949 scopus 로고    scopus 로고
    • Classification of compressed breast shapes for the design of equalization filters in x-ray mammography
    • MM Goodsitt, H Chan, B Liu, S V Guru, A R Morton, S Keshavmurthy and N Petrick, "Classification of compressed breast shapes for the design of equalization filters in x-ray mammography," Med. Phys. 25(6), 937-948 (1998)
    • (1998) Med. Phys , vol.25 , Issue.6 , pp. 937-948
    • Goodsitt, M.M.1    Chan, H.2    Liu, B.3    Guru, S.V.4    Morton, A.R.5    Keshavmurthy, S.6    Petrick, N.7
  • 8
    • 0032692240 scopus 로고    scopus 로고
    • A simple theorem relating noise and patient dose in computed tomography
    • MD Harpen, "A simple theorem relating noise and patient dose in computed tomography," Med. Phys. 26(11), 2231-2234(1999)
    • (1999) Med. Phys , vol.26 , Issue.11 , pp. 2231-2234
    • Harpen, M.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.