Simplified method of scatter correction using a beam-stop-array algorithm for cone-beam computed tomography breast imaging

Author keywords

Cone beam CT; Medical imaging; Scatter correction; X ray imaging

Indexed keywords

AIR-GAPS; ANGULAR POSITIONS; BREAST IMAGING; BREAST PHANTOM; CIRCULAR ORBIT; CONE BEAM; CONE-BEAM COMPUTED TOMOGRAPHY; CONE-BEAM CT; CONTRAST LOSS; CUPPING ARTIFACTS; FIELD OF VIEWS; LINEAR ATTENUATION COEFFICIENTS; PROTOTYPE SYSTEM; RECONSTRUCTION ERROR; RECONSTRUCTION IMAGE; ROTATIONAL AXIS; SCATTER CORRECTION; SIMPLIFIED METHOD; X-RAY EXPOSURE; X-RAY IMAGING;

EID: 75749098740     PISSN: 00913286     EISSN: 15602303     Source Type: Journal    
DOI: 10.1117/1.2977527     Document Type: Article
Times cited : (16)

References (11)
  • 1
    • 0042377130 scopus 로고    scopus 로고
    • Real time flat panel detector-based cone beam volume CT breast imaging: Phantom and specimen study
    • R. Ning, D. Conover, Y. Yu, L. Schiffhauer, X. Lu, J. Cullinan, and A. Robinson, " Real time flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study.," Proc. SPIE 5030, 180-190 (2003).
    • (2003) Proc. SPIE , vol.5030 , pp. 180-190
    • Ning, R.1    Conover, D.2    Yu, Y.3    Schiffhauer, L.4    Lu, X.5    Cullinan, J.6    Robinson, A.7
  • 2
    • 0034871399 scopus 로고    scopus 로고
    • Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT
    • X. Tang, R. Ning, R. Yu, and D. Conover, " Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT.," Proc. SPIE 4320, 851-860 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 851-860
    • Tang, X.1    Ning, R.2    Yu, R.3    Conover, D.4
  • 3
    • 0021868276 scopus 로고
    • Scatter rejection by air gaps: An empirical model
    • J. A. Sorenson and J. Floch, " Scatter rejection by air gaps: an empirical model.," Med. Phys. 12, 308-316 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 308-316
    • Sorenson, J.A.1    Floch, J.2
  • 4
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • U. Neitzel, " Grids or air gaps for scatter reduction in digital radiography: a model calculation.," Med. Phys. 19, 475-481 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 475-481
    • Neitzel, U.1
  • 5
    • 0038372096 scopus 로고    scopus 로고
    • The values of scatter removal by a grid in full field digital mammography
    • W. J. Veldkamp, M. Thijssen, and N. Karssemijer, " The values of scatter removal by a grid in full field digital mammography.," Med. Phys. 30, 1712-1718 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1712-1718
    • Veldkamp, W.J.1    Thijssen, M.2    Karssemijer, N.3
  • 6
    • 0023752571 scopus 로고
    • X-ray scatter removal by deconvolution
    • J. A. Seibert and J. M. Boone, " X-ray scatter removal by deconvolution.," Med. Phys. 15, 567-575 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 567-575
    • Seibert, J.A.1    Boone, J.M.2
  • 7
    • 0023212881 scopus 로고
    • Scatter estimation for a digital radiographic system using convolution filtering
    • L. A. Love and R. A. Kruger, " Scatter estimation for a digital radiographic system using convolution filtering.," Med. Phys. 14, 178-185 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 178-185
    • Love, L.A.1    Kruger, R.A.2
  • 8
    • 0036032227 scopus 로고    scopus 로고
    • X-ray scatter suppression algorithm for cone beam volume CT
    • R. Ning, X. Tang, and D. Conover, " X-ray scatter suppression algorithm for cone beam volume CT.," Proc. SPIE 4682, 774-781 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 774-781
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 9
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • R. Ning and X. Tang, " X-ray scatter correction algorithm for cone beam CT imaging.," Med. Phys. 31, 1195-1202 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1195-1202
    • Ning, R.1    Tang, X.2
  • 10
    • 25644435753 scopus 로고    scopus 로고
    • Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner
    • A. L. Kwan, J. M. Boone, and N. Shah, " Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner.," Med. Phys. 32, 2967-2975 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2967-2975
    • Kwan, A.L.1    Boone, J.M.2    Shah, N.3
  • 11
    • 35148889476 scopus 로고    scopus 로고
    • Complete MTF evaluation of two cone beam CT systems
    • R. Betancourt-Benitez, R. Ning, and D. Conover, " Complete MTF evaluation of two cone beam CT systems.," Proc. SPIE 6510, 65104I (2007).
    • (2007) Proc. SPIE , vol.6510
    • Betancourt-Benitez, R.1    Ning, R.2    Conover, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.