메뉴 건너뛰기




Volumn 37, Issue 4, 2011, Pages 749-757

In vivo 7.1 T magnetic resonance imaging to assess the lens geometry in rabbit eyes 3 years after lens-refilling surgery

Author keywords

[No Author keywords available]

Indexed keywords

DACTINOMYCIN; METHOTREXATE; POLYMER; SILICONE;

EID: 79952938805     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2010.10.057     Document Type: Article
Times cited : (15)

References (21)
  • 2
    • 38649102454 scopus 로고    scopus 로고
    • Variability of axial length, anterior chamber depth, and lens thickness in the cataractous eye
    • DOI 10.1016/j.jcrs.2007.10.015, PII S0886335007019219
    • R. Jivrajka, M.C. Shammas, T. Boenzi, M. Swearingen, and H.J. Shammas Variability of axial length, anterior chamber depth, and lens thickness in the cataractous eye J Cataract Refract Surg 34 2008 289 294 (Pubitemid 351173614)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.2 , pp. 289-294
    • Jivrajka, R.1    Shammas, M.C.2    Boenzi, T.3    Swearingen, M.4    Shammas, H.J.5
  • 3
    • 61849174065 scopus 로고    scopus 로고
    • Comparison of the behavior of natural and refilled porcine lenses in a robotic lens stretcher
    • M.A. Reilly, P.D. Hamilton, G. Perry, and N. Ravi Comparison of the behavior of natural and refilled porcine lenses in a robotic lens stretcher Exp Eye Res 88 2009 483 494
    • (2009) Exp Eye Res , vol.88 , pp. 483-494
    • Reilly, M.A.1    Hamilton, P.D.2    Perry, G.3    Ravi, N.4
  • 5
    • 22944432848 scopus 로고    scopus 로고
    • Refractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracing
    • W. Fink Refractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracing J Biomed Opt 10 2005 024003 Available at: http://autonomy.caltech.edu/publications/journals/ JBO024003published.pdf Accessed November 9, 2010
    • (2005) J Biomed Opt , vol.10 , pp. 024003
    • Fink, W.1
  • 6
    • 15044354941 scopus 로고    scopus 로고
    • Optical coherence tomography assessment of capsule closure after cataract surgery
    • DOI 10.1016/j.jcrs.2004.04.057
    • S. Sacu, O. Findl, and R.J. Linnola Optical coherence tomography assessment of capsule closure after cataract surgery J Cataract Refract Surg 31 2005 330 336 (Pubitemid 40379640)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.2 , pp. 330-336
    • Sacu, S.1    Findl, O.2    Linnola, R.J.3
  • 7
    • 33845674457 scopus 로고    scopus 로고
    • Advances in anterior segment imaging
    • DOI 10.1097/ICU.0b013e328011550d, PII 0005573520070200000009
    • J.S. Wolffsohn, and L.N. Davies Advances in anterior segment imaging Curr Opin Ophthalmol 18 2007 32 38 (Pubitemid 44949824)
    • (2007) Current Opinion in Ophthalmology , vol.18 , Issue.1 , pp. 32-38
    • Wolffsohn, J.S.1    Davies, L.N.2
  • 10
    • 79952953333 scopus 로고    scopus 로고
    • inventors; AMO Groningen, B.V., assignee US patent 7 182 780. February 27 Available at: Accessed November 9, 2010
    • Terwee T, Koopmans S, inventors; AMO Groningen, B.V., assignee. Device for use in eye surgery. US patent 7 182 780. February 27, 2007. Available at: http://www.freepatentsonline.com/7182780.pdf. Accessed November 9, 2010
    • (2007) Device for Use in Eye Surgery
    • Terwee, T.1    Koopmans, S.2
  • 11
    • 79952978804 scopus 로고    scopus 로고
    • inventors; Pharmacia & Upjohn AB, assignee US Patent 6 066 172. May 23, 2000. Available at: Accessed November 9, 2010
    • Huo PP, Zhou SQ, Liau CJY, Norrby S, inventors; Pharmacia & Upjohn AB, assignee. Injectable intraocular lens. US Patent 6 066 172. May 23, 2000. Available at: http://www.freepatentsonline.com/6066172.pdf. Accessed November 9, 2010
    • Injectable Intraocular Lens
    • Huo, P.P.1    Zhou, S.Q.2    Cjy, L.3    Norrby, S.4
  • 12
    • 33144482184 scopus 로고    scopus 로고
    • Artificial crystalline lens
    • DOI 10.1016/j.ohc.2005.10.001, PII S0896154905001070, Accommodation and Presbyopic Correction Options
    • S. Norrby, S. Koopmans, and T. Terwee Artificial crystalline lens Ophthalmol Clin North Am 19 1 2006 143 146 (Pubitemid 43267479)
    • (2006) Ophthalmology Clinics of North America , vol.19 , Issue.1 , pp. 143-146
    • Norrby, S.1    Koopmans, S.2    Terwee, T.3
  • 13
    • 77955299258 scopus 로고    scopus 로고
    • Drug-induced secondary cataract prevention: Experimental ex vivo and in vivo results with disulfiram, methotrexate and actinomycin D
    • K. Sternberg, T. Terwee, O. Stachs, R. Guthoff, M. Löbler, and K.-P. Schmitz Drug-induced secondary cataract prevention: experimental ex vivo and in vivo results with disulfiram, methotrexate and actinomycin D Ophthalmic Res 44 2010 225 236
    • (2010) Ophthalmic Res , vol.44 , pp. 225-236
    • Sternberg, K.1    Terwee, T.2    Stachs, O.3    Guthoff, R.4    Löbler, M.5    Schmitz, K.-P.6
  • 14
    • 0027987239 scopus 로고
    • Accommodation of an endocapsular silicone lens (Phaco-Ersatz) in the aging rhesus monkey
    • E. Haefliger, and J.-M. Parel Accommodation of an endocapsular silicone lens (phaco-ersatz) in the aging rhesus monkey J Refract Corneal Surg 10 1994 550 555 (Pubitemid 24338793)
    • (1994) Journal of Refractive and Corneal Surgery , vol.10 , Issue.5 , pp. 550-555
    • Haefliger, E.1    Parel, J.-M.2
  • 15
    • 0028202437 scopus 로고
    • Lens refilling and endocapsular polymerization of an injectable intraocular lens: In vitro and in vivo study of potential risks and benefits
    • H.-J. Hettlich, K. Lucke, M.N. Asiyo-Vogel, M. Schulte, and A. Vogel Lens refilling and endocapsular polymerization of an injectable intraocular lens: in vitro and in vivo study of potential risks and benefits J Cataract Refract Surg 20 1994 115 123 (Pubitemid 24100161)
    • (1994) Journal of Cataract and Refractive Surgery , vol.20 , Issue.2 , pp. 115-123
    • Hettlich, H.-J.1    Lucke, K.2    Asiyo-Vogel, M.N.3    Schulte, M.4    Vogel, A.5
  • 17
    • 0027442624 scopus 로고
    • Amplitudes of accommodation of primate lenses refilled with two types of inflatable endocapsular balloons
    • O. Nishi, Y. Nakai, Y. Yamada, and Y. Mizumoto Amplitudes of accommodation of primate lenses refilled with two types of inflatable endocapsular balloons Arch Ophthalmol 111 1993 1677 1684 Available at: http://archopht.ama-assn.org/cgi/reprint/111/12/1677 Accessed November 10, 2010 (Pubitemid 23361505)
    • (1993) Archives of Ophthalmology , vol.111 , Issue.12 , pp. 1677-1684
    • Nishi, O.1    Nakai, Y.2    Yamada, Y.3    Mizumoto, Y.4
  • 18
    • 0030978234 scopus 로고    scopus 로고
    • Controlling the capsular shape in lens refilling
    • O. Nishi, K. Nishi, C. Mano, M. Ichihara, and T. Honda Controlling the capsular shape in lens refilling Arch Ophthalmol 115 1997 507 510 Available at: http://archopht.ama-assn.org/cgi/reprint/115/4/507.pdf Accessed November 10, 2010 (Pubitemid 27172707)
    • (1997) Archives of Ophthalmology , vol.115 , Issue.4 , pp. 507-510
    • Nishi, O.1    Nishi, K.2    Mano, C.3    Ichihara, M.4    Honda, T.5
  • 19
    • 38649085926 scopus 로고    scopus 로고
    • Capsular bag refilling using a new accommodating intraocular lens
    • DOI 10.1016/j.jcrs.2007.09.042, PII S0886335007019700
    • O. Nishi, K. Nishi, Y. Nishi, and S. Chang Capsular bag refilling using a new accommodating intraocular lens J Cataract Refract Surg 34 2008 302 309 (Pubitemid 351173627)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.2 , pp. 302-309
    • Nishi, O.1    Nishi, K.2    Nishi, Y.3    Chang, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.