메뉴 건너뛰기




Volumn 18, Issue 1, 2011, Pages 42-45

Electromagnetic navigation bronchoscopy in the diagnosis of peripheral lung lesions

Author keywords

Diagnostic yield; Electromagnetic navigation bronchoscopy; Pneumothorax

Indexed keywords

ARTICLE; BRONCHOSCOPY; COMPUTER ASSISTED TOMOGRAPHY; CYTOPATHOLOGY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; ELECTROMAGNETIC NAVIGATION BRONCHOSCOPY; ESOPHAGOSCOPY; FEVER; FLUOROSCOPY; HEMATOMA; HEMOPTYSIS; HUMAN; INTERSTITIAL LUNG DISEASE; LUNG ALVEOLUS CELL CARCINOMA; LUNG ASPERGILLOSIS; LUNG BIOPSY; LUNG CANCER; LUNG GRANULOMA; LUNG NODULE; LUNG TUMOR; MEDIASTINOSCOPY; PATIENT SAFETY; PERIPHERAL LUNG LESION; PNEUMONIA; PNEUMOTHORAX; POSITRON EMISSION TOMOGRAPHY; RADIATION PNEUMONIA; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY; SORE THROAT; THORACOTOMY; THORAX PAIN; TRANSTHORACIC ASPIRATION; VOMITING;

EID: 79952768591     PISSN: 10680640     EISSN: None     Source Type: Journal    
DOI: 10.1097/CPM.0b013e318203657e     Document Type: Article
Times cited : (6)

References (26)
  • 1
    • 23044445755 scopus 로고    scopus 로고
    • Innovative bronchoscopic diagnostic techniques: Endobronchial ultrasound and electromagnetic navigation
    • Herth FJ, Ernst A. Innovative diagnostic techniques: endobronchial ultrasound and electromagnetic navigation. Curr Opin Pulm Med. 2005;11:278-281. (Pubitemid 41073148)
    • (2005) Current Opinion in Pulmonary Medicine , vol.11 , Issue.4 , pp. 278-281
    • Herth, F.J.F.1    Ernst, A.2
  • 2
    • 73149110471 scopus 로고    scopus 로고
    • Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer
    • Smith-Bindman R, Lipson J, Marcus R, et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009;169:2078-2086.
    • (2009) Arch Intern Med , vol.169 , pp. 2078-2086
    • Smith-Bindman, R.1    Lipson, J.2    Marcus, R.3
  • 3
    • 0034008350 scopus 로고    scopus 로고
    • Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules
    • Baaklini W, Reinoso M, Gorin A, et al. Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. Chest. 2000;117:1049-1054. (Pubitemid 30228362)
    • (2000) Chest , vol.117 , Issue.4 , pp. 1049-1054
    • Baaklini, W.A.1    Reinoso, M.A.2    Gorin, A.B.3    Sharafkaneh, A.4    Manian, P.5
  • 4
    • 0018649602 scopus 로고
    • Diagnostic accuracy in peripheral lung lesions. Factors predicting success with flexible fiberoptic bronchoscopy
    • Radke JR, Conway WA, Eyler WR, et al. Diagnostic accuracy in peripheral lung lesions: factors predicting success with flexible fiberoptic bronchoscopy. Chest. 1979;76:176-179. (Pubitemid 9247745)
    • (1979) Chest , vol.76 , Issue.2 , pp. 176-179
    • Radke, J.R.1    Conway, W.A.2    Eyler, W.R.3    Kvale, P.A.4
  • 5
    • 0018410976 scopus 로고
    • Biopsy and brushing of peripheral lung cancer with fluoroscopic guidance
    • Cortese DA, McDougall JC. Biopsy and brushing of peripheral lung cancer with fluoroscopic guidance. Chest. 1979;75:141-145. (Pubitemid 9128105)
    • (1979) Chest , vol.75 , Issue.2 , pp. 141-145
    • Cortese, D.A.1    McDougall, J.C.2
  • 7
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate
    • DOI 10.1148/radiol.2291020499
    • Geraghty PR, Kee ST, McFarlane G, et al. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229:475-481. (Pubitemid 37310835)
    • (2003) Radiology , vol.229 , Issue.2 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3    Razavi, M.K.4    Sze, D.Y.5    Dake, M.D.6
  • 8
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, et al. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology. 1996;198:371-375. (Pubitemid 26036839)
    • (1996) Radiology , vol.198 , Issue.2 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3    Martinez, F.J.4
  • 10
    • 0029970058 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules
    • Li H, Boiselle PM, Shepard J-AO, et al. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol. 1996;167:105-109. (Pubitemid 26196919)
    • (1996) American Journal of Roentgenology , vol.167 , Issue.1 , pp. 105-109
    • Li, H.1    Boiselle, P.M.2    Shepard, J.-A.O.3    Trotman-Dickenson, B.4    McLoud, T.C.5
  • 11
    • 0032721261 scopus 로고    scopus 로고
    • Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: Incidence and risk factors
    • Laurent F, Michel P, Latrabe V, et al. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol. 1999;172:1049-1053. (Pubitemid 29505637)
    • (1999) American Journal of Roentgenology , vol.172 , Issue.4 , pp. 1049-1053
    • Laurent, F.1    Michel, P.2    Latrabe, V.3    De Lara, M.T.4    Marthan, R.5
  • 12
    • 0030749570 scopus 로고    scopus 로고
    • CT Guided fine-needle aspiration cytology of solitary pulmonary nodules
    • Santambrogio L, Nosotti M, Bellaviti N, et al. CT Guided fine-needle aspiration cytology of solitary pulmonary nodules. Chest. 1997;112:423-425.
    • (1997) Chest , vol.112 , pp. 423-425
    • Santambrogio, L.1    Nosotti, M.2    Bellaviti, N.3
  • 13
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest. 2004;126:748-754.
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3
  • 14
    • 22244437588 scopus 로고    scopus 로고
    • Electromagnetic catheter navigation during bronchoscopy: Validation of a novel method by conventional fluoroscopy
    • DOI 10.1378/chest.128.1.382
    • Hautmann H, Schneider A, Pinkau T, et al. Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy. Chest. 2005;128:382-387. (Pubitemid 40994498)
    • (2005) Chest , vol.128 , Issue.1 , pp. 382-387
    • Hautmann, H.1    Schneider, A.2    Pinkau, T.3    Peltz, F.4    Feussner, H.5
  • 15
    • 0035035768 scopus 로고    scopus 로고
    • Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) workshop summary
    • Pauwels RA, Buist AS, Calverley PM, et al. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med. 2001;163:1256-1276. (Pubitemid 32378468)
    • (2001) American Journal of Respiratory and Critical Care Medicine , vol.163 , Issue.5 , pp. 1256-1276
    • Pauwels, R.A.1    Buist, A.S.2    Calverley, P.M.A.3    Jenkins, C.R.4    Hurd, S.S.5
  • 16
    • 12144259377 scopus 로고    scopus 로고
    • Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance: A pilot study
    • DOI 10.1097/01.laboratory.0000147032.67754.22
    • Becker HD, Herth F, Ernst A, et al. Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance. A pilot study. J Bronchol. 2005;12:9-13. (Pubitemid 40110713)
    • (2005) Journal of Bronchology , vol.12 , Issue.1 , pp. 9-13
    • Becher, H.D.1    Herth, F.2    Ernst, A.3    Schwarz, Y.4
  • 18
    • 33645981940 scopus 로고    scopus 로고
    • Real-Time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: The first human study
    • Schwarz Y, Greif J, Becker H, et al. Real-Time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. Chest. 2006;129:988-994.
    • (2006) Chest , vol.129 , pp. 988-994
    • Schwarz, Y.1    Greif, J.2    Becker, H.3
  • 20
    • 34250866220 scopus 로고    scopus 로고
    • Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions
    • DOI 10.1378/chest.06-3016
    • Eberhardt R, Anantham D, Herth F, et al. Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions. Chest. 2007;131:1800-1805. (Pubitemid 46981637)
    • (2007) Chest , vol.131 , Issue.6 , pp. 1800-1805
    • Eberhardt, R.1    Anantham, D.2    Herth, F.3    Feller-Kopman, D.4    Ernst, A.5
  • 22
    • 40349085843 scopus 로고    scopus 로고
    • Improved diagnostic yield of bronchoscopy in a community practice: Combination of electromagnetic navigation system and rapid on-site evaluation
    • DOI 10.1097/LBR.0b013e31815a7b00, PII 0012859420071000000003
    • Wilson DS, Bartlett R. Improved diagnostic yield of bronchoscopy in a community practice: combination of electromagnetic navigation system and rapid on-site evaluation. J Bronchol. 2007;14:227-232. (Pubitemid 351339533)
    • (2007) Journal of Bronchology , vol.14 , Issue.4 , pp. 227-232
    • Wilson, D.S.1    Bartlett, R.J.2
  • 23
    • 58249109547 scopus 로고    scopus 로고
    • Electromagnetic navigation bronchoscopy in combination with PET-CT and Rapid On-site Cytopathologic Examination for diagnosis of peripheral lung lesions
    • Lamprecht B, Porsch P, Pirich C, et al. Electromagnetic navigation bronchoscopy in combination with PET-CT and Rapid On-site Cytopathologic Examination for diagnosis of peripheral lung lesions. Lung. 2009;187:55-59.
    • (2009) Lung , vol.187 , pp. 55-59
    • Lamprecht, B.1    Porsch, P.2    Pirich, C.3
  • 24
    • 78649853479 scopus 로고    scopus 로고
    • Diagnostic yield of electromagnetic navigation bronchoscopy is highly dependent on the presence of a bronchus sign on CT: Results from a prospective study
    • on line publication
    • Seijo LM, Torres JP, Lozano MD, et al. Diagnostic yield of electromagnetic navigation bronchoscopy is highly dependent on the presence of a bronchus sign on CT: results from a prospective study. Chest: on line publication. http://chestjournal.chestpubs.org/content/early/2010/04/28/chest. 09-2708
    • Chest
    • Seijo, L.M.1    Torres, J.P.2    Lozano, M.D.3
  • 25
    • 73349142675 scopus 로고    scopus 로고
    • Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy
    • Eberhardt R, Morgan RK, Ernst A, et al. Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy. Respiration. 2010;79:54-60.
    • (2010) Respiration , vol.79 , pp. 54-60
    • Eberhardt, R.1    Morgan, R.K.2    Ernst, A.3
  • 26
    • 0037245905 scopus 로고    scopus 로고
    • Overview of methodology for lung cancer evidence review and guidance development
    • McCroy DC, Colice GL, Lewis SZ, et al. Overview of methodology for lung cancer evidence review and guidance development. Chest. 2003;123(suppl 1):3S-6S.
    • (2003) Chest , vol.123 , Issue.SUPPL. 1
    • McCroy, D.C.1    Colice, G.L.2    Lewis, S.Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.