메뉴 건너뛰기




Volumn 174, Issue 9, 2006, Pages 982-989

Electromagnetic navigation diagnostic bronchoscopy: A prospective study

Author keywords

Diagnostic bronchoscopy; Electromagnetic navigation; Mediastinal lymph node; Solitary pulmonary nodule; Transbronchial biopsy

Indexed keywords

ADULT; AGED; ARTICLE; BRONCHOSCOPY; CANCER DIAGNOSIS; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ELECTROMAGNETIC NAVIGATION BRONCHOSCOPY; FEMALE; HUMAN; LUNG CANCER; LUNG INJURY; MAJOR CLINICAL STUDY; MALE; MEDIASTINUM LYMPH NODE; MEDICAL SOCIETY; PNEUMOTHORAX; PRIORITY JOURNAL; PROSPECTIVE STUDY;

EID: 33750603072     PISSN: 1073449X     EISSN: 1073449X     Source Type: Journal    
DOI: 10.1164/rccm.200603-344OC     Document Type: Article
Times cited : (408)

References (45)
  • 2
    • 0017158726 scopus 로고
    • Diagnostic accuracy in lung cancer; comparison of techniques used in association with flexible fiberoptic bronchoscopy
    • Kvale PA, Bode FR, Kini S. Diagnostic accuracy in lung cancer; comparison of techniques used in association with flexible fiberoptic bronchoscopy. Chest 1976;69:752-757.
    • (1976) Chest , vol.69 , pp. 752-757
    • Kvale, P.A.1    Bode, F.R.2    Kini, S.3
  • 4
    • 0018649602 scopus 로고
    • Diagnostic accuracy in peripheral lung lesions. Factors predicting success with flexible fiberoptic bronchoscopy
    • Radke JR, Conway WA, Eyler WR, Kvale PA. Diagnostic accuracy in peripheral lung lesions. Factors predicting success with flexible fiberoptic bronchoscopy. Chest 1979;76:176-179.
    • (1979) Chest , vol.76 , pp. 176-179
    • Radke, J.R.1    Conway, W.A.2    Eyler, W.R.3    Kvale, P.A.4
  • 5
    • 0037246876 scopus 로고    scopus 로고
    • Performance characteristics of different modalities for diagnosis of suspected lung cancer: Summary of published evidence
    • Schreiber G, McCrory DC. Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. Chest 2003;123:115S-128S.
    • (2003) Chest , vol.123
    • Schreiber, G.1    McCrory, D.C.2
  • 6
    • 0019965553 scopus 로고
    • Flexible fiberoptic bronchoscopy and percutaneous needle lung aspiration for evaluating the solitary pulmonary nodule
    • Wallace JM, Deutsch AL. Flexible fiberoptic bronchoscopy and percutaneous needle lung aspiration for evaluating the solitary pulmonary nodule. Chest 1982;81:665-671.
    • (1982) Chest , vol.81 , pp. 665-671
    • Wallace, J.M.1    Deutsch, A.L.2
  • 7
    • 0024564624 scopus 로고
    • Transbronchial needle aspiration in the practice of bronchoscopy
    • Gay PC, Brutinel WM. Transbronchial needle aspiration in the practice of bronchoscopy. Mayo Clin Proc 1989;64:158-162.
    • (1989) Mayo Clin Proc , vol.64 , pp. 158-162
    • Gay, P.C.1    Brutinel, W.M.2
  • 8
    • 0034008350 scopus 로고    scopus 로고
    • Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules
    • Baaklini WA, Reinoso MA, Gorin AB, Sharafkaneh A, Manian P. Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. Chest 2000;117:1049-1054.
    • (2000) Chest , vol.117 , pp. 1049-1054
    • Baaklini, W.A.1    Reinoso, M.A.2    Gorin, A.B.3    Sharafkaneh, A.4    Manian, P.5
  • 9
    • 14244271459 scopus 로고    scopus 로고
    • Transbronchial needle aspiration of central and peripheral nodules
    • Rajamani S, Mehta AC. Transbronchial needle aspiration of central and peripheral nodules. Monaldi Arch Chest Dis 2001;56:436-445.
    • (2001) Monaldi Arch Chest Dis , vol.56 , pp. 436-445
    • Rajamani, S.1    Mehta, A.C.2
  • 11
    • 4544346103 scopus 로고    scopus 로고
    • Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically
    • Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, Murayama M. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest 2004;126:959-965.
    • (2004) Chest , vol.126 , pp. 959-965
    • Kurimoto, N.1    Miyazawa, T.2    Okimasa, S.3    Maeda, A.4    Oiwa, H.5    Miyazu, Y.6    Murayama, M.7
  • 12
  • 13
    • 0036174923 scopus 로고    scopus 로고
    • Ultrathin bronchoscopy as an adjunct to standard bronchoscopy in the diagnosis of peripheral lung lesions: A preliminary report
    • Rooney CP, Wolf K, McLennan G. Ultrathin bronchoscopy as an adjunct to standard bronchoscopy in the diagnosis of peripheral lung lesions: a preliminary report. Respiration (Herrlisheim) 2002;69:63-68.
    • (2002) Respiration (Herrlisheim) , vol.69 , pp. 63-68
    • Rooney, C.P.1    Wolf, K.2    McLennan, G.3
  • 14
    • 12144259377 scopus 로고    scopus 로고
    • Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance: A pilot study
    • Becker HD, Herth F, Ernst A, Schwarz Y. Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance: a pilot study. J Bronchol 2005;12:9-13.
    • (2005) J Bronchol , vol.12 , pp. 9-13
    • Becker, H.D.1    Herth, F.2    Ernst, A.3    Schwarz, Y.4
  • 16
    • 33645981940 scopus 로고    scopus 로고
    • Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: The first human study
    • Schwarz Y, Greif Y, Becker H, Ernst A, Mehta A. Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. Chest 2006;129:988-994.
    • (2006) Chest , vol.129 , pp. 988-994
    • Schwarz, Y.1    Greif, Y.2    Becker, H.3    Ernst, A.4    Mehta, A.5
  • 17
    • 22244437588 scopus 로고    scopus 로고
    • Electromagnetic catheter navigation during bronchoscopy: Validation of a novel method by conventional fluoroscopy
    • Hautmann H, Schneider A, Pinkau T, Peltz F, Feussner H. Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy. Chest 2005;128:382-387.
    • (2005) Chest , vol.128 , pp. 382-387
    • Hautmann, H.1    Schneider, A.2    Pinkau, T.3    Peltz, F.4    Feussner, H.5
  • 18
    • 33750590677 scopus 로고    scopus 로고
    • Electromagnetic navigation bronchoscopy
    • [abstract]
    • Gildea TR. Electromagnetic navigation bronchoscopy [abstract]. Lung Cancer 2005;49:s433.
    • (2005) Lung Cancer , vol.49
    • Gildea, T.R.1
  • 19
    • 0033846132 scopus 로고    scopus 로고
    • Mediastinal lymphadenopathy: Diagnostic yield of transbronchial mediastinal lymph node biopsy with CT fluoroscopic guidance-initial experience
    • Goldberg SN, Raptopoulos V, Boiselle PM, Edinburgh KJ, Ernst A. Mediastinal lymphadenopathy: diagnostic yield of transbronchial mediastinal lymph node biopsy with CT fluoroscopic guidance-initial experience. Radiology 2000;216:764-767.
    • (2000) Radiology , vol.216 , pp. 764-767
    • Goldberg, S.N.1    Raptopoulos, V.2    Boiselle, P.M.3    Edinburgh, K.J.4    Ernst, A.5
  • 21
    • 0026045903 scopus 로고
    • Needle brush in the diagnosis of lung mass or nodule through flexible bronchoscopy
    • Wang KP, Britt EJ. Needle brush in the diagnosis of lung mass or nodule through flexible bronchoscopy. Chest 1991;100:1148-1150.
    • (1991) Chest , vol.100 , pp. 1148-1150
    • Wang, K.P.1    Britt, E.J.2
  • 23
    • 7944236458 scopus 로고    scopus 로고
    • Enhanced virtual bronchoscopy using the pulmonary artery: Improvement in route mapping for ultraselective transbronchial lung biopsy
    • Onodera Y, Omatsu T, Takeucji S, Shinagawa N, Yamazaki K, Nishioka T, Miyasaka K. Enhanced virtual bronchoscopy using the pulmonary artery: improvement in route mapping for ultraselective transbronchial lung biopsy. AJR Am J Roentgenol 2004;183:1103-1110.
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1103-1110
    • Onodera, Y.1    Omatsu, T.2    Takeucji, S.3    Shinagawa, N.4    Yamazaki, K.5    Nishioka, T.6    Miyasaka, K.7
  • 24
    • 0036193616 scopus 로고    scopus 로고
    • Bronchoscopy and needle biopsy techniques for diagnosis and staging of lung cancer
    • Mazzone P, Jain P, Arroliga AC, Matthay RA. Bronchoscopy and needle biopsy techniques for diagnosis and staging of lung cancer. Clin Chest Med 2002;23:137-158.
    • (2002) Clin Chest Med , vol.23 , pp. 137-158
    • Mazzone, P.1    Jain, P.2    Arroliga, A.C.3    Matthay, R.A.4
  • 26
    • 0346363594 scopus 로고    scopus 로고
    • Yield of transbronchial needle aspiration in diagnosis of mediastinal lesions
    • Sharafkhaneh A, Baaklini W, Gorin AB, Green L. Yield of transbronchial needle aspiration in diagnosis of mediastinal lesions. Chest 2003;124:2131-2135.
    • (2003) Chest , vol.124 , pp. 2131-2135
    • Sharafkhaneh, A.1    Baaklini, W.2    Gorin, A.B.3    Green, L.4
  • 28
    • 24944584617 scopus 로고    scopus 로고
    • Transbronchial biopsy using endobronchial ultrasonography with a guide sheath and virtual bronchoscopic navigation
    • Asahina H, Yamazaki K, Onodera Y, Kikuchi E, Shinagawa N, Asano F, Nishimura M. Transbronchial biopsy using endobronchial ultrasonography with a guide sheath and virtual bronchoscopic navigation. Chest 2005;128:1761-1765.
    • (2005) Chest , vol.128 , pp. 1761-1765
    • Asahina, H.1    Yamazaki, K.2    Onodera, Y.3    Kikuchi, E.4    Shinagawa, N.5    Asano, F.6    Nishimura, M.7
  • 30
    • 33144456977 scopus 로고    scopus 로고
    • Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules
    • Herth F, Eberhardt R, Becker H, Ernst A. Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules. Chest 2006;129:147-150.
    • (2006) Chest , vol.129 , pp. 147-150
    • Herth, F.1    Eberhardt, R.2    Becker, H.3    Ernst, A.4
  • 31
    • 28144435546 scopus 로고    scopus 로고
    • Combining bronchoscopy and positron emission tmomography for the diagnosis of the small pulmonary nodule ≤ 3 cm
    • Chhajed P, Bernasconi M, Gambazzi F, Bubendorf L, Rasch H, Kneifel S, Tamm M. Combining bronchoscopy and positron emission tmomography for the diagnosis of the small pulmonary nodule ≤ 3 cm. Chest 2005;128:3558-3564.
    • (2005) Chest , vol.128 , pp. 3558-3564
    • Chhajed, P.1    Bernasconi, M.2    Gambazzi, F.3    Bubendorf, L.4    Rasch, H.5    Kneifel, S.6    Tamm, M.7
  • 33
    • 4544346103 scopus 로고    scopus 로고
    • Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically
    • Kurimoto N, Miyazawa T, Okimasa S, Maeda A, Oiwa H, Miyazu Y, Murayama M. Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically. Chest 2004;126:959-965.
    • (2004) Chest , vol.126 , pp. 959-965
    • Kurimoto, N.1    Miyazawa, T.2    Okimasa, S.3    Maeda, A.4    Oiwa, H.5    Miyazu, Y.6    Murayama, M.7
  • 34
    • 3242685309 scopus 로고    scopus 로고
    • Real-time endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes
    • Yasufuku K, Chiyo M, Sekine Y, Chhajed P, Shibuya K, Iizasa T, Fujisawa T. Real-time endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes. Chest 2004;126:122-128.
    • (2004) Chest , vol.126 , pp. 122-128
    • Yasufuku, K.1    Chiyo, M.2    Sekine, Y.3    Chhajed, P.4    Shibuya, K.5    Iizasa, T.6    Fujisawa, T.7
  • 35
    • 1642575308 scopus 로고    scopus 로고
    • Conventional vs endobronchial ultrasound-guided transbronchial needle aspiration: A randomized trial
    • Herth F, Becker HD, Ernst A. Conventional vs endobronchial ultrasound-guided transbronchial needle aspiration: a randomized trial. Chest 2004;125:322-325.
    • (2004) Chest , vol.125 , pp. 322-325
    • Herth, F.1    Becker, H.D.2    Ernst, A.3
  • 36
    • 0037249628 scopus 로고    scopus 로고
    • The noninvasive staging of non-small cell lung cancer: The guidelines
    • American College of Chest Physicians
    • Silvestri GA, Tanoue LT, Margolis ML, Barker J, Detterbeck F. American College of Chest Physicians. The noninvasive staging of non-small cell lung cancer: the guidelines. Chest 2003;123:147S-156S.
    • (2003) Chest , vol.123
    • Silvestri, G.A.1    Tanoue, L.T.2    Margolis, M.L.3    Barker, J.4    Detterbeck, F.5
  • 38
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate
    • Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003;229:475-481.
    • (2003) Radiology , vol.229 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3    Razavi, M.K.4    Sze, D.Y.5    Dake, M.D.6
  • 39
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC, Chou AS. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 2004;126:748-754.
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3    Tsay, P.K.4    Lui, K.W.5    Cheung, Y.C.6    Chou, A.S.7
  • 41
    • 10444247397 scopus 로고    scopus 로고
    • Lung cancer: Clinical presentation and specialist referral time
    • Buccheri G, Ferrigno D. Lung cancer: clinical presentation and specialist referral time. Eur Respir J 2004;24:898-904.
    • (2004) Eur Respir J , vol.24 , pp. 898-904
    • Buccheri, G.1    Ferrigno, D.2
  • 42
    • 5144230291 scopus 로고    scopus 로고
    • State-of-the-art screening for lung cancer (part 1): The chest radiograph
    • Freedman M. State-of-the-art screening for lung cancer (part 1): the chest radiograph. Thorac Surg Clin 2004;14:43-52.
    • (2004) Thorac Surg Clin , vol.14 , pp. 43-52
    • Freedman, M.1
  • 43
    • 5144221611 scopus 로고    scopus 로고
    • State-of-the-art screening for lung cancer: (Part 2): CT scanning
    • Yankelevitz D, Henschke CI. State-of-the-art screening for lung cancer: (part 2): CT scanning. Thorac Surg Clin 2004;14:53-59.
    • (2004) Thorac Surg Clin , vol.14 , pp. 53-59
    • Yankelevitz, D.1    Henschke, C.I.2
  • 44
    • 0024424821 scopus 로고
    • Transbronchial biopsy without fluoroscopy: A five year experience in outpatients
    • de Fenoyl O, Capron F, Lebeau B, Rochemaure J. Transbronchial biopsy without fluoroscopy: a five year experience in outpatients. Thorax 1989;44:956-959.
    • (1989) Thorax , vol.44 , pp. 956-959
    • De Fenoyl, O.1    Capron, F.2    Lebeau, B.3    Rochemaure, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.