메뉴 건너뛰기




Volumn 29, Issue 6, 2007, Pages 1187-1192

Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions

Author keywords

Bronchoscopy; Computed tomography; Pulmonary nodule; Three dimensional imaging

Indexed keywords

ADULT; ARTICLE; BRONCHOSCOPE; BRONCHOSCOPY; CALCULATION; CANCER STAGING; CATHETER; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EARLY DIAGNOSIS; ELECTROMAGNETIC NAVIGATION GUIDED BRONCHOSCOPY; FEMALE; FLUOROSCOPY; HUMAN; HUMAN TISSUE; INOPERABLE CANCER; LUNG CANCER; LUNG INJURY; MALE; PATIENT SAFETY; PLEURA; PNEUMOTHORAX; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSOR; TERTIARY HEALTH CARE; THORAX DRAINAGE; TRANSBRONCHIAL BIOPSY;

EID: 34250162135     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1183/09031936.00165306     Document Type: Article
Times cited : (212)

References (35)
  • 2
    • 32644460488 scopus 로고    scopus 로고
    • International Early Lung Cancer Action Program Investigators. Computed tomographic screening for lung cancer: The relationship of disease stage to tumor size
    • Henschke CI, Yankelevitz DF, Miettinen OS, International Early Lung Cancer Action Program Investigators. Computed tomographic screening for lung cancer: the relationship of disease stage to tumor size. Arch Intern Med 2006; 166: 321-325.
    • (2006) Arch Intern Med , vol.166 , pp. 321-325
    • Henschke, C.I.1    Yankelevitz, D.F.2    Miettinen, O.S.3
  • 3
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • Sone S, Takashima S, Li F, et al. Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 1998; 351: 1242-1245.
    • (1998) Lancet , vol.351 , pp. 1242-1245
    • Sone, S.1    Takashima, S.2    Li, F.3
  • 4
    • 17744365185 scopus 로고    scopus 로고
    • Early lung cancer action project: A summary of the findings on baseline screening
    • Henschke CI, McCauley DI, Yankelevitz DF, et al. Early lung cancer action project: a summary of the findings on baseline screening. Oncologist 2001; 6: 147-152.
    • (2001) Oncologist , vol.6 , pp. 147-152
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 5
    • 20144389751 scopus 로고    scopus 로고
    • CT screening for lung cancer: Five-year prospective experience
    • Swensen SJ, Jett JR, Hartman TE, et al. CT screening for lung cancer: five-year prospective experience. Radiology 2005; 235: 259-265.
    • (2005) Radiology , vol.235 , pp. 259-265
    • Swensen, S.J.1    Jett, J.R.2    Hartman, T.E.3
  • 6
    • 33745593962 scopus 로고    scopus 로고
    • Validity of the assessment of quality of life (AQoL) utility instrument in patients with operable and inoperable lung cancer
    • Manser RL, Wright G, Byrnes G, et al. Validity of the assessment of quality of life (AQoL) utility instrument in patients with operable and inoperable lung cancer. Lung Cancer 2006; 53: 217-229.
    • (2006) Lung Cancer , vol.53 , pp. 217-229
    • Manser, R.L.1    Wright, G.2    Byrnes, G.3
  • 7
    • 0034895137 scopus 로고    scopus 로고
    • Radical radiotherapy for stage I/II non-small cell lung cancer in patients not sufficiently fit for or declining surgery (medically inoperable) a systematic review
    • Rowell NP, Williams CJ. Radical radiotherapy for stage I/II non-small cell lung cancer in patients not sufficiently fit for or declining surgery (medically inoperable) a systematic review. Thorax 2001; 56: 628-638.
    • (2001) Thorax , vol.56 , pp. 628-638
    • Rowell, N.P.1    Williams, C.J.2
  • 8
    • 0027366755 scopus 로고
    • The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule
    • Torrington KC, Kern JD. The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule. Chest 1993; 104: 1021-1024.
    • (1993) Chest , vol.104 , pp. 1021-1024
    • Torrington, K.C.1    Kern, J.D.2
  • 9
    • 0020150241 scopus 로고
    • Flexible fiberoptic bronchoscopy and fluoroscopically guided transbronchial biopsy in the management of solitary pulmonary nodules
    • Fletcher EC, Levin DC. Flexible fiberoptic bronchoscopy and fluoroscopically guided transbronchial biopsy in the management of solitary pulmonary nodules. West J Med 1982; 136: 477-483.
    • (1982) West J Med , vol.136 , pp. 477-483
    • Fletcher, E.C.1    Levin, D.C.2
  • 10
    • 0034008350 scopus 로고    scopus 로고
    • Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules
    • Baaklini W, Reinoso M, Gorin A, Sharafkaneh A, Manian P. Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules. Chest 2000; 117: 1049-1054.
    • (2000) Chest , vol.117 , pp. 1049-1054
    • Baaklini, W.1    Reinoso, M.2    Gorin, A.3    Sharafkaneh, A.4    Manian, P.5
  • 11
    • 0021024006 scopus 로고
    • Transbronchial needle aspiration of peripheral masses
    • Shure D, Fedullo PF. Transbronchial needle aspiration of peripheral masses. Am Rev Respir Dis 1983; 128: 1090-1092.
    • (1983) Am Rev Respir Dis , vol.128 , pp. 1090-1092
    • Shure, D.1    Fedullo, P.F.2
  • 12
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate
    • Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003; 229: 475-481.
    • (2003) Radiology , vol.229 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3    Razavi, M.K.4    Sze, D.Y.5    Dake, M.D.6
  • 13
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996; 198: 371-375.
    • (1996) Radiology , vol.198 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3    Martinez, F.J.4
  • 14
    • 0038512071 scopus 로고    scopus 로고
    • CT-guided transthoracic needle aspiration biopsy of small (< or=20 mm) solitary pulmonary nodules
    • Ohno Y, Hatabu H, Takenaka D, et al. CT-guided transthoracic needle aspiration biopsy of small (< or=20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 2003; 180: 1665-1669.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 1665-1669
    • Ohno, Y.1    Hatabu, H.2    Takenaka, D.3
  • 15
    • 0029907832 scopus 로고    scopus 로고
    • Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders
    • Kato R, Katada K, Anno H, Suzuki S, Ida Y, Koga S. Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. Radiology 1996; 201: 576-578.
    • (1996) Radiology , vol.201 , pp. 576-578
    • Kato, R.1    Katada, K.2    Anno, H.3    Suzuki, S.4    Ida, Y.5    Koga, S.6
  • 16
    • 0018649602 scopus 로고
    • Diagnostic accuracy in peripheral lung lesions: Factors predicting success with flexible fiberoptic bronchoscopy
    • Radke JR, Conway WA, Eyler WR, Kvale PA. Diagnostic accuracy in peripheral lung lesions: factors predicting success with flexible fiberoptic bronchoscopy. Chest 1979; 76: 176-179.
    • (1979) Chest , vol.76 , pp. 176-179
    • Radke, J.R.1    Conway, W.A.2    Eyler, W.R.3    Kvale, P.A.4
  • 17
    • 0018410976 scopus 로고
    • Biopsy and brushing of peripheral lung cancer with fluoroscopic guidance
    • Cortese DA, McDougall JC. Biopsy and brushing of peripheral lung cancer with fluoroscopic guidance. Chest 1979; 75: 141-145.
    • (1979) Chest , vol.75 , pp. 141-145
    • Cortese, D.A.1    McDougall, J.C.2
  • 18
    • 0029970058 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules
    • Li H, Boiselle PM, Shepard J-AO, Trotman-Dickenson B, McLoud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 1996; 167: 105-109.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 105-109
    • Li, H.1    Boiselle, P.M.2    Shepard, J.-A.O.3    Trotman-Dickenson, B.4    McLoud, T.C.5
  • 19
    • 0032721261 scopus 로고    scopus 로고
    • Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: Incidence and risk factors
    • Laurent F, Michel P, Latrabe V, Tunon de Lara M, Marthan R. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol 1999; 172: 1049-1053.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 1049-1053
    • Laurent, F.1    Michel, P.2    Latrabe, V.3    Tunon de Lara, M.4    Marthan, R.5
  • 20
    • 0346139498 scopus 로고    scopus 로고
    • Electromagnetic navigation during flexible bronchoscope
    • Schwarz Y, Mehta AC, Ernst A, et al. Electromagnetic navigation during flexible bronchoscope. Respiration 2003; 70: 516-522.
    • (2003) Respiration , vol.70 , pp. 516-522
    • Schwarz, Y.1    Mehta, A.C.2    Ernst, A.3
  • 21
    • 33144456977 scopus 로고    scopus 로고
    • Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules: A prospective trial
    • Herth FJ, Eberhardt R, Becker HD, Ernst A. Endobronchial ultrasound-guided transbronchial lung biopsy in fluoroscopically invisible solitary pulmonary nodules: a prospective trial. Chest 2006; 129: 147-150.
    • (2006) Chest , vol.129 , pp. 147-150
    • Herth, F.J.1    Eberhardt, R.2    Becker, H.D.3    Ernst, A.4
  • 22
    • 22244437588 scopus 로고    scopus 로고
    • Electromagnetic catheter navigation during bronchoscopy validation of a novel method by conventional fluoroscopy
    • Hautmann H, Schneider A, Pinkau T, Peltz F, Feussner H. Electromagnetic catheter navigation during bronchoscopy validation of a novel method by conventional fluoroscopy. Chest 2005; 128: 382-387.
    • (2005) Chest , vol.128 , pp. 382-387
    • Hautmann, H.1    Schneider, A.2    Pinkau, T.3    Peltz, F.4    Feussner, H.5
  • 23
    • 33645981940 scopus 로고    scopus 로고
    • Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: The first human study
    • Schwarz Y, Greif J, Becker HD, Ernst A, Mehta A. Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study. Chest 2006; 129: 988-994.
    • (2006) Chest , vol.129 , pp. 988-994
    • Schwarz, Y.1    Greif, J.2    Becker, H.D.3    Ernst, A.4    Mehta, A.5
  • 25
    • 0037246876 scopus 로고    scopus 로고
    • Performance characteristics of different modalities for diagnosis of suspected lung cancer: Summary of published evidence
    • Schreiber G, McCrory DC. Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. Chest 2003; 123: Suppl. 1, 115S-128S.
    • (2003) Chest , vol.123 , Issue.SUPPL. 1
    • Schreiber, G.1    McCrory, D.C.2
  • 27
    • 0033223475 scopus 로고    scopus 로고
    • Integration of TBNA and TCNA in the diagnosis of peripheral lung nodules. Influence on staging
    • Gasparini S, Zuccatosta L, Zitti P, et al. Integration of TBNA and TCNA in the diagnosis of peripheral lung nodules. Influence on staging. Ann Ital Chir 1999; 70: 851-855.
    • (1999) Ann Ital Chir , vol.70 , pp. 851-855
    • Gasparini, S.1    Zuccatosta, L.2    Zitti, P.3
  • 28
    • 0032905580 scopus 로고    scopus 로고
    • Radiation safety for health care workers in the bronchoscopy suite
    • Jain P, Fleming P, Mehta AC. Radiation safety for health care workers in the bronchoscopy suite. Clin Chest Med 1999; 20: 33-38.
    • (1999) Clin Chest Med , vol.20 , pp. 33-38
    • Jain, P.1    Fleming, P.2    Mehta, A.C.3
  • 29
    • 0029012331 scopus 로고
    • The role of transbronchial needle aspiration in the diagnosis of peripheral lung masses or nodules
    • Katis K, Inglesos E, Zachariadis E, et al. The role of transbronchial needle aspiration in the diagnosis of peripheral lung masses or nodules. Eur Respir J 1995; 8: 963-966.
    • (1995) Eur Respir J , vol.8 , pp. 963-966
    • Katis, K.1    Inglesos, E.2    Zachariadis, E.3
  • 30
    • 0021077394 scopus 로고
    • Modern thirty-day operative mortality for surgical resections in lung cancer
    • Ginsberg RJ, Hill LD, Eagan RT, et al. Modern thirty-day operative mortality for surgical resections in lung cancer. J Thorac Cardiovasc Surg 1983; 86: 654-658.
    • (1983) J Thorac Cardiovasc Surg , vol.86 , pp. 654-658
    • Ginsberg, R.J.1    Hill, L.D.2    Eagan, R.T.3
  • 32
    • 0037392166 scopus 로고    scopus 로고
    • Radiofrequency ablation of pulmonary malignant tumors in nonsurgical candidates
    • Herrera LJ, Fernando HC, Perry Y, et al. Radiofrequency ablation of pulmonary malignant tumors in nonsurgical candidates. J Thorac Cardiovasc Surg 2003; 125: 929-937.
    • (2003) J Thorac Cardiovasc Surg , vol.125 , pp. 929-937
    • Herrera, L.J.1    Fernando, H.C.2    Perry, Y.3
  • 33
    • 28444449481 scopus 로고    scopus 로고
    • Improving the quality of cytology diagnosis: Root cause analysis for errors in bronchial washing and brushing specimens
    • Nodit L, Balassanian R, Sudilovsky D, Raab SS. Improving the quality of cytology diagnosis: root cause analysis for errors in bronchial washing and brushing specimens. Am J Clin Pathol 2005; 124: 883-892.
    • (2005) Am J Clin Pathol , vol.124 , pp. 883-892
    • Nodit, L.1    Balassanian, R.2    Sudilovsky, D.3    Raab, S.S.4
  • 34
    • 0031974246 scopus 로고    scopus 로고
    • Techniques in human airway inflammation: Quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes
    • Aleva RM, Kraan J, Smith M, ten Hacken NH, Postma DS, Timens W. Techniques in human airway inflammation: quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes. Chest 1998; 113: 182-185.
    • (1998) Chest , vol.113 , pp. 182-185
    • Aleva, R.M.1    Kraan, J.2    Smith, M.3    ten Hacken, N.H.4    Postma, D.S.5    Timens, W.6
  • 35
    • 1642281129 scopus 로고    scopus 로고
    • CT-guided transbronchial biopsy using an ultrathin bronchoscope with virtual bronchoscopic navigation
    • Shinagawa N, Yamazaki K, Onodera Y, et al. CT-guided transbronchial biopsy using an ultrathin bronchoscope with virtual bronchoscopic navigation. Chest 2004; 125: 1138-1143.
    • (2004) Chest , vol.125 , pp. 1138-1143
    • Shinagawa, N.1    Yamazaki, K.2    Onodera, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.