Comparison of non-calibrated pulse-contour analysis with continuous thermodilution for cardiac output assessment in patients with induced hypothermia after cardiac arrest

Author keywords

Cardiac arrest; Cardiac output measurement; Hypothermia; Pulse contour analysis; Resuscitation

Indexed keywords

ADULT; AGED; ARTERIAL BLOOD PRESSURE CONTOUR ANALYSIS; ARTICLE; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; HEART ARREST; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HUMAN; INDUCED HYPOTHERMIA; MALE; MONITOR; PRIORITY JOURNAL; RESUSCITATION; TEMPERATURE; THERMODILUTION;

EID: 79952625149     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.12.015     Document Type: Article
Times cited : (11)

References (27)
  • 1
    • 33646065525 scopus 로고    scopus 로고
    • American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care
    • ECC Committee SaTFotAHA
    • ECC Committee SaTFotAHA American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2005, 112:1-203.
    • (2005) Circulation , vol.112 , pp. 1-203
  • 3
    • 34648831279 scopus 로고    scopus 로고
    • Cardiac output from the arterial catheter: deceptively simple
    • Manecke G.R. Cardiac output from the arterial catheter: deceptively simple. J Cardiothorac Vasc Anesth 2007, 21:629-631.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 629-631
    • Manecke, G.R.1
  • 4
    • 26844502897 scopus 로고    scopus 로고
    • Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    • Manecke G.R. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Rev Med Dev 2005, 2:523-527.
    • (2005) Expert Rev Med Dev , vol.2 , pp. 523-527
    • Manecke, G.R.1
  • 6
    • 59849104492 scopus 로고    scopus 로고
    • Failure of continuous cardiac output measurement using the PiCCO Device during induced hypothermia: a case report
    • Ong T., Gillies M.A., Bellomo R. Failure of continuous cardiac output measurement using the PiCCO Device during induced hypothermia: a case report. Crit Care Resus 2004, 6:99-101.
    • (2004) Crit Care Resus , vol.6 , pp. 99-101
    • Ong, T.1    Gillies, M.A.2    Bellomo, R.3
  • 7
    • 33646764584 scopus 로고    scopus 로고
    • In vitro response time of continuous cardiac output measurement in STAT mode of Vigilance after controlled flow change
    • Nakamura R., Izumi H., Shioyama K., Koga T., Shigeoka H., Akiyama R. In vitro response time of continuous cardiac output measurement in STAT mode of Vigilance after controlled flow change. Masui 2006, 55:630-634.
    • (2006) Masui , vol.55 , pp. 630-634
    • Nakamura, R.1    Izumi, H.2    Shioyama, K.3    Koga, T.4    Shigeoka, H.5    Akiyama, R.6
  • 8
    • 0029992651 scopus 로고    scopus 로고
    • Delayed time response of the continuous cardiac output pulmonary artery catheter
    • Siegel L.C., Hennessy M.M., Pearl R.G. Delayed time response of the continuous cardiac output pulmonary artery catheter. Anesth Analg 1996, 83:1173-1177.
    • (1996) Anesth Analg , vol.83 , pp. 1173-1177
    • Siegel, L.C.1    Hennessy, M.M.2    Pearl, R.G.3
  • 9
    • 0034005504 scopus 로고    scopus 로고
    • Comparing methods of clinical measurement: reporting standards for Bland and Altman analysis
    • Mantha S., Roizen M.F., Fleisher L.A., Thisted R., Foss J. Comparing methods of clinical measurement: reporting standards for Bland and Altman analysis. Anesth Analg 2000, 90:593-602.
    • (2000) Anesth Analg , vol.90 , pp. 593-602
    • Mantha, S.1    Roizen, M.F.2    Fleisher, L.A.3    Thisted, R.4    Foss, J.5
  • 10
    • 34548208591 scopus 로고    scopus 로고
    • Using the Bland-Altman method to measure agreement with repeated measures
    • Myles P.S., Cui J. Using the Bland-Altman method to measure agreement with repeated measures. Br J Anaesth 2007, 99:309-311.
    • (2007) Br J Anaesth , vol.99 , pp. 309-311
    • Myles, P.S.1    Cui, J.2
  • 11
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland J.M., Altman D.G. Measuring agreement in method comparison studies. Stat Methods Med Res 1999, 8:135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley L.A., Critchley J.A. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999, 15:85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 13
    • 34648816655 scopus 로고    scopus 로고
    • Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
    • Breukers R.M., Sepehrkhouy S., Spiegelenberg S.R., Groeneveld A.B. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth 2007, 21:632-635.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 632-635
    • Breukers, R.M.1    Sepehrkhouy, S.2    Spiegelenberg, S.R.3    Groeneveld, A.B.4
  • 14
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • 1480-6, table
    • Biais M., Nouette-Gaulain K., Cottenceau V., et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 2008, 106. 1480-6, table.
    • (2008) Anesth Analg , vol.106
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3
  • 15
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J., Boldt J., Schollhorn T., Rohm K.D., Mengistu A.M., Suttner S. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007, 98:176-182.
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3    Rohm, K.D.4    Mengistu, A.M.5    Suttner, S.6
  • 16
    • 36549031653 scopus 로고    scopus 로고
    • Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial
    • McGee W.T., Horswell J.L., Calderon J., et al. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial. Crit Care 2007, 11:R105.
    • (2007) Crit Care , vol.11
    • McGee, W.T.1    Horswell, J.L.2    Calderon, J.3
  • 17
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • de Waal E.E., Kalkman C.J., Rex S., Buhre W.F. Validation of a new arterial pulse contour-based cardiac output device. Crit Care Med 2007, 35:1904-1909.
    • (2007) Crit Care Med , vol.35 , pp. 1904-1909
    • de Waal, E.E.1    Kalkman, C.J.2    Rex, S.3    Buhre, W.F.4
  • 18
    • 34548254794 scopus 로고    scopus 로고
    • Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis
    • Sakka S.G., Kozieras J., Thuemer O., van Hout N. Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth 2007, 99:337-342.
    • (2007) Br J Anaesth , vol.99 , pp. 337-342
    • Sakka, S.G.1    Kozieras, J.2    Thuemer, O.3    van Hout, N.4
  • 19
    • 57349199888 scopus 로고    scopus 로고
    • Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery
    • Biancofiore G., Critchley L.A., Lee A., et al. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery. Br J Anaesth 2009, 102:47-54.
    • (2009) Br J Anaesth , vol.102 , pp. 47-54
    • Biancofiore, G.1    Critchley, L.A.2    Lee, A.3
  • 20
    • 34648831355 scopus 로고    scopus 로고
    • Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform
    • Lorsomradee S., Lorsomradee S., Cromheecke S., De Hert S.G. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth 2007, 21:636-643.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 636-643
    • Lorsomradee, S.1    Lorsomradee, S.2    Cromheecke, S.3    De Hert, S.G.4
  • 21
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    • Bein B., Meybohm P., Cavus E., et al. The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg 2007, 105:107-113.
    • (2007) Anesth Analg , vol.105 , pp. 107-113
    • Bein, B.1    Meybohm, P.2    Cavus, E.3
  • 22
    • 34447642740 scopus 로고    scopus 로고
    • Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability
    • Johansson A., Chew M. Reliability of continuous pulse contour cardiac output measurement during hemodynamic instability. J Clin Monit Comput 2007, 21:237-242.
    • (2007) J Clin Monit Comput , vol.21 , pp. 237-242
    • Johansson, A.1    Chew, M.2
  • 23
    • 0029926874 scopus 로고    scopus 로고
    • Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery
    • Bottiger B.W., Soder M., Rauch H., et al. Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery. Intensive Care Med 1996, 22:312-318.
    • (1996) Intensive Care Med , vol.22 , pp. 312-318
    • Bottiger, B.W.1    Soder, M.2    Rauch, H.3
  • 24
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • Boldt J., Menges T., Wollbruck M., Hammermann H., Hempelmann G. Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?. Crit Care Med 1994, 22:1913-1918.
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3    Hammermann, H.4    Hempelmann, G.5
  • 25
    • 11144335979 scopus 로고    scopus 로고
    • The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults
    • Dark P.M., Singer M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med 2004, 30:2060-2066.
    • (2004) Intensive Care Med , vol.30 , pp. 2060-2066
    • Dark, P.M.1    Singer, M.2
  • 26
    • 41949139754 scopus 로고    scopus 로고
    • Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients
    • Compton F.D., Zukunft B., Hoffmann C., Zidek W., Schaefer J.H. Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac/Vigileo) in haemodynamically unstable patients. Br J Anaesth 2008, 100:451-456.
    • (2008) Br J Anaesth , vol.100 , pp. 451-456
    • Compton, F.D.1    Zukunft, B.2    Hoffmann, C.3    Zidek, W.4    Schaefer, J.H.5
  • 27
    • 0036042186 scopus 로고    scopus 로고
    • Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock
    • Sun Q., Rogiers P., Pauwels D., Vincent J.L. Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock. Intensive Care Med 2002, 28:1276-1280.
    • (2002) Intensive Care Med , vol.28 , pp. 1276-1280
    • Sun, Q.1    Rogiers, P.2    Pauwels, D.3    Vincent, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.