메뉴 건너뛰기




Volumn , Issue , 2010, Pages 202-205

Implantable stimulator for bipolar stimulation without charge balancing circuits

Author keywords

[No Author keywords available]

Indexed keywords

ANODIC CURRENTS; BIPHASIC; BLOCKING CAPACITOR; CHARGE BALANCES; CHARGE IMBALANCE; CHARGE-BALANCING CIRCUITS; CURRENT PULSE; FULL SCALE; HV CMOS; IMPLANTABLE STIMULATORS; NEURAL STIMULATIONS; POWER SUPPLY; RESIDUAL DC; TISSUE DAMAGE;

EID: 79952405737     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2010.5709606     Document Type: Conference Paper
Times cited : (17)

References (11)
  • 1
    • 0032722732 scopus 로고    scopus 로고
    • Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli
    • R. Shepherd, "Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli," Acta oto-laryngologica, vol. 119, no. 6, pp. 674-684, 1999.
    • (1999) Acta Oto-laryngologica , vol.119 , Issue.6 , pp. 674-684
    • Shepherd, R.1
  • 3
    • 39549119112 scopus 로고    scopus 로고
    • A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6 nA DC error for 1-mA full-scale stimulation
    • J. Sit and R. Sarpeshkar, "A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6 nA DC error for 1-mA full-scale stimulation," IEEE Trans. Biomed. Circuits Syst, vol. 1, no. 3, pp. 172-183, 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst , vol.1 , Issue.3 , pp. 172-183
    • Sit, J.1    Sarpeshkar, R.2
  • 8
    • 79952387471 scopus 로고    scopus 로고
    • Progress Towards A High-Resolution Retinal Prosthesis
    • J. Weil, W. Fink, M. Humayun, W. Liu, D. Rodger, C. Tai, and M. Tarbell, "Progress Towards A High-Resolution Retinal Prosthesis," Relation, vol. 10, no. 1.132, p. 5025, 2008.
    • (2008) Relation , vol.10 , Issue.1-132 , pp. 5025
    • Weil, J.1    Fink, W.2    Humayun, M.3    Liu, W.4    Rodger, D.5    Tai, C.6    Tarbell, M.7
  • 10
    • 78049324417 scopus 로고    scopus 로고
    • Cmos current reference generator using integrated resistors
    • Aug.
    • H. Chun and T. Lehmann, "Cmos current reference generator using integrated resistors," ICEIE 2010, vol. 1, pp. 290-294, Aug. 2010.
    • (2010) ICEIE 2010 , vol.1 , pp. 290-294
    • Chun, H.1    Lehmann, T.2
  • 11
    • 56349162989 scopus 로고    scopus 로고
    • An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
    • X. Liu, A. Demosthenous, and N. Donaldson, "An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors, " IEEE Trans. Biomed. Circuits Syst, vol. 2, no. 3, pp. 231-244, 2008.
    • (2008) IEEE Trans. Biomed. Circuits Syst , vol.2 , Issue.3 , pp. 231-244
    • Liu, X.1    Demosthenous, A.2    Donaldson, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.