메뉴 건너뛰기




Volumn , Issue , 2009, Pages 61-64

Biphasic-current-pulse self-calibration techniques for monopolar current stimulation

Author keywords

[No Author keywords available]

Indexed keywords

BIPHASIC; BLOCKING CAPACITOR; CALIBRATION CIRCUITS; CATHODIC PULSE; CHARGE BALANCES; CMOS PROCESSS; CURRENT AMPLITUDE; CURRENT PULSE; DESIGN CHALLENGES; HIGH-VOLTAGES; LONG DURATION; MAXIMUM AMPLITUDE; NEURAL PROSTHETIC; RESIDUAL DC; SELF CALIBRATION; SELF-CALIBRATION TECHNIQUES; TRANSMISSION GATE;

EID: 77749308615     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2009.5372085     Document Type: Conference Paper
Times cited : (25)

References (6)
  • 1
    • 0032722732 scopus 로고    scopus 로고
    • Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli
    • R. K. Shepherd, N. Linahan, J. Xu, G. M. Clark, and S. Araki, "Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli," Acta Otolaryngologica, vol. 119, no. 6, pp. 674-684, 1999.
    • (1999) Acta Otolaryngologica , vol.119 , Issue.6 , pp. 674-684
    • Shepherd, R.K.1    Linahan, N.2    Xu, J.3    Clark, G.M.4    Araki, S.5
  • 2
    • 39549119112 scopus 로고    scopus 로고
    • A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6nA DC error for 1-mA full-scale stimulation
    • Sep
    • J. J. Sit, and R. Sarpeshkar, "A low-power blocking-capacitor-free charge-balanced electrode-stimulator chip with less than 6nA DC error for 1-mA full-scale stimulation," IEEE Tran. Biomedical Circuits Syst., vol. 1, no. 3, pp. 172-183, Sep. 2007.
    • (2007) IEEE Tran. Biomedical Circuits Syst , vol.1 , Issue.3 , pp. 172-183
    • Sit, J.J.1    Sarpeshkar, R.2
  • 3
    • 0031106664 scopus 로고    scopus 로고
    • Chronic electrical stimulation of the auditory nerve at high stimulus rates: A physiological and histopathological study
    • J. Xu, R. K. Shepherd, R. E. Millard, and G. M. Clark, "Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study," Hearing Res. vol. 105, pp. 1-29, 1997.
    • (1997) Hearing Res , vol.105 , pp. 1-29
    • Xu, J.1    Shepherd, R.K.2    Millard, R.E.3    Clark, G.M.4
  • 4
    • 16244368094 scopus 로고    scopus 로고
    • A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device
    • Mar
    • M. Sivaprakasam, W. Liu, M. S. Humayun, and J. D. Weiland, "A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device," IEEE J. Solid-State Circuits, vol. 40, no. 3, pp. 763 - 771, Mar. 2005.
    • (2005) IEEE J. Solid-State Circuits , vol.40 , Issue.3 , pp. 763-771
    • Sivaprakasam, M.1    Liu, W.2    Humayun, M.S.3    Weiland, J.D.4
  • 6
    • 57849145698 scopus 로고    scopus 로고
    • A 9-bit configurable current source with enhanced output resistance for cochlear stimulators
    • Sep
    • S. Guo, H. Lee, and P. Loizou, "A 9-bit configurable current source with enhanced output resistance for cochlear stimulators," in Proc. IEEE Custom Integrated Circuits Conference, Sep. 2008, pp. 511-514.
    • (2008) Proc. IEEE Custom Integrated Circuits Conference , pp. 511-514
    • Guo, S.1    Lee, H.2    Loizou, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.