메뉴 건너뛰기




Volumn 17, Issue 1, 2009, Pages

Rigid fibrescope Bonfils: Use in simulated difficult airway by novices

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL COMPETENCE; COMPARATIVE STUDY; ENDOTRACHEAL INTUBATION; EQUIPMENT DESIGN; HUMAN; INSTRUMENTATION; METHODOLOGY; RESPIRATION CONTROL; TASK PERFORMANCE;

EID: 79952277401     PISSN: None     EISSN: 17577241     Source Type: Journal    
DOI: 10.1186/1757-7241-17-33     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 0036716397 scopus 로고    scopus 로고
    • Advanced prehospital airway management techniques
    • 10.1097/00063110-200209000-00019 12394633
    • Advanced prehospital airway management techniques. AR Thierbach, Eur J Emerg Med 2002 9 298 302 10.1097/00063110-200209000-00019 12394633
    • (2002) Eur J Emerg Med , vol.9 , pp. 298-302
    • Thierbach, A.R.1
  • 2
    • 0000270555 scopus 로고
    • A new laryngoscope
    • 10.1016/S0140-6736(00)89390-3
    • A new laryngoscope. R Macintosh, Lancet 1943 i 205 10.1016/S0140-6736(00) 89390-3
    • (1943) Lancet , vol.1 , pp. 205
    • MacIntosh, R.1
  • 3
    • 10044242511 scopus 로고    scopus 로고
    • The incidence and risk factors for cardiac arrest during emergency tracheal intubation: A justification for incorporating the ASA Guidelines in the remote location
    • DOI 10.1016/j.jclinane.2004.01.007, PII S0952818004001394
    • The incidence and risk factors for cardiac arrest during emergency tracheal intubation: a justification for incorporating the ASA Guidelines in the remote location. TC Mort, J Clin Anesth 2004 16 508 516 10.1016/j.jclinane. 2004.01.007 15590254 (Pubitemid 39601824)
    • (2004) Journal of Clinical Anesthesia , vol.16 , Issue.7 , pp. 508-516
    • Mort, T.C.1
  • 5
    • 3042833661 scopus 로고    scopus 로고
    • Prehospital emergency airway management procedures. Success rates and complications
    • 10.1007/s00101-004-0679-z 15088093
    • [Prehospital emergency airway management procedures. Success rates and complications]. A Thierbach T Piepho B Wolcke S Kuster W Dick, Anaesthesist 2004 53 543 550 10.1007/s00101-004-0679-z 15088093
    • (2004) Anaesthesist , vol.53 , pp. 543-550
    • Thierbach, A.1    Piepho, T.2    Wolcke, B.3    Kuster, S.4    Dick, W.5
  • 6
    • 0030986343 scopus 로고    scopus 로고
    • A prospectivein-field evaluation of endotracheal intubation byemergency medical services physicians
    • A prospectivein-field evaluation of endotracheal intubation byemergency medical services physicians. G Orliaguet S Tartiere M Lejay, J Eur Urgences 1997 1 27 32
    • (1997) J Eur Urgences , vol.1 , pp. 27-32
    • Orliaguet, G.1    Tartiere, S.2    Lejay, M.3
  • 7
    • 56849116223 scopus 로고    scopus 로고
    • Airway management in the outpatient setting: New devices and techniques
    • 10.1097/ACO.0b013e328316bb57 18997523
    • Airway management in the outpatient setting: new devices and techniques. L Jolliffe I Jackson, Curr Opin Anaesthesiol 2008 21 719 722 10.1097/ACO.0b013e328316bb57 18997523
    • (2008) Curr Opin Anaesthesiol , vol.21 , pp. 719-722
    • Jolliffe, L.1    Jackson, I.2
  • 8
    • 43449132101 scopus 로고    scopus 로고
    • Airway techniques and ventilation strategies
    • DOI 10.1097/MCC.0b013e3282f85bc8, PII 0007519820080600000007
    • Airway techniques and ventilation strategies. JP Nolan J Soar, Curr Opin Crit Care 2008 14 279 286 10.1097/MCC.0b013e3282f85bc8 18467887 (Pubitemid 351667912)
    • (2008) Current Opinion in Critical Care , vol.14 , Issue.3 , pp. 279-286
    • Nolan, J.P.1    Soar, J.2
  • 9
    • 58149349966 scopus 로고    scopus 로고
    • The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation-an observational study concerning ERC guidelines 2005
    • 10.1016/j.resuscitation.2008.08.023 19010582
    • The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation-an observational study concerning ERC guidelines 2005. CH Wiese T Semmel JU Muller J Bahr H Ocker BM Graf, Resuscitation 2009 80 194 198 10.1016/j.resuscitation.2008.08.023 19010582
    • (2009) Resuscitation , vol.80 , pp. 194-198
    • Wiese, C.H.1    Semmel, T.2    Muller, J.U.3    Bahr, J.4    Ocker, H.5    Graf, B.M.6
  • 10
    • 33846025809 scopus 로고    scopus 로고
    • Prehospital emergency endotracheal intubation using the Bonfils intubation fiberscope
    • DOI 10.1097/01.mej.0000195680.08533.57, PII 0006311020070200000010
    • Prehospital emergency endotracheal intubation using the Bonfils intubation fiberscope. C Byhahn D Meininger F Walcher C Hofstetter B Zwissler, Eur J Emerg Med 2007 14 43 46 10.1097/01.mej.0000195680.08533.57 17198327 (Pubitemid 46052141)
    • (2007) European Journal of Emergency Medicine , vol.14 , Issue.1 , pp. 43-46
    • Byhahn, C.1    Meininger, D.2    Walcher, F.3    Hofstetter, C.4    Zwissler, B.5
  • 11
    • 0242269437 scopus 로고    scopus 로고
    • A clinical evaluation of the Bonfils Intubation Fibrescope
    • DOI 10.1046/j.1365-2044.2003.03407.x
    • A clinical evaluation of the Bonfils Intubation Fibrescope. M Halligan P Charters, Anaesthesia 2003 58 1087 1091 10.1046/j.1365-2044.2003.03407.x 14616594 (Pubitemid 37361113)
    • (2003) Anaesthesia , vol.58 , Issue.11 , pp. 1087-1091
    • Halligan, M.1    Charters, P.2
  • 12
    • 3242891660 scopus 로고    scopus 로고
    • A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways
    • DOI 10.1111/j.1365-2044.2004.03778.x
    • A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways. B Bein F Worthmann J Scholz F Brinkmann PH Tonner M Steinfath V Dorges, Anaesthesia 2004 59 668 674 10.1111/j.1365-2044.2004.03778.x 15200542 (Pubitemid 38997009)
    • (2004) Anaesthesia , vol.59 , Issue.7 , pp. 668-674
    • Bein, B.1    Worthmann, F.2    Scholz, J.3    Brinkmann, F.4    Tonner, P.H.5    Steinfath, M.6    Dorges, V.7
  • 13
    • 10044224412 scopus 로고    scopus 로고
    • Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy
    • DOI 10.1111/j.1365-2044.2004.03967.x
    • Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy. B Bein M Yan PH Tonner J Scholz M Steinfath V Dorges, Anaesthesia 2004 59 1207 1209 10.1111/j.1365-2044.2004.03967.x 15549980 (Pubitemid 39600161)
    • (2004) Anaesthesia , vol.59 , Issue.12 , pp. 1207-1209
    • Bein, B.1    Yan, M.2    Tonner, P.H.3    Scholz, J.4    Steinfath, M.5    Dorges, V.6
  • 14
    • 4243874433 scopus 로고    scopus 로고
    • Learning curve for the Bonfils intubation fibrescope
    • Learning curve for the Bonfils intubation fibrescope. M Halligan P Charters, Br J Anaesth 2003 90 826P
    • (2003) Br J Anaesth , vol.90
    • Halligan, M.1    Charters, P.2
  • 15
    • 0032983085 scopus 로고    scopus 로고
    • Airway management during cardiopulmonary resuscitation-a comparative study of bag-valve-mask, laryngeal mask airway and combitube in a bench model
    • DOI 10.1016/S0300-9572(99)00036-2, PII S0300957299000362
    • Airway management during cardiopulmonary resuscitation a comparative study of bag-valve-mask, laryngeal mask airway and combitube in a bench model. V Doerges C Sauer H Ocker V Wenzel P Schmucker, Resuscitation 1999 41 63 69 10.1016/S0300-9572(99)00036-2 10459594 (Pubitemid 29317585)
    • (1999) Resuscitation , vol.41 , Issue.1 , pp. 63-69
    • Doerges, V.1    Sauer, C.2    Ocker, H.3    Wenzel, V.4    Schmucker, P.5
  • 16
    • 33847616968 scopus 로고    scopus 로고
    • The laryngeal tube device: a simple and timely adjunct to airway management
    • DOI 10.1016/j.ajem.2006.03.018, PII S0735675706001057
    • The laryngeal tube device: a simple and timely adjunct to airway management. CS Russi CL Wilcox HR House, Am J Emerg Med 2007 25 263 267 10.1016/j.ajem.2006.03.018 17349898 (Pubitemid 46356853)
    • (2007) American Journal of Emergency Medicine , vol.25 , Issue.3 , pp. 263-267
    • Russi, C.S.1    Wilcox, C.L.2    House, H.R.3
  • 17
    • 25644453662 scopus 로고    scopus 로고
    • Bullard laryngoscopy by naive operators in the cervical spine immobilized patient
    • DOI 10.1016/j.jemermed.2005.01.025, PII S0736467905001514
    • Bullard laryngoscopy by naive operators in the cervical spine immobilized patient. A Wackett K Anderson H Thode, J Emerg Med 2005 29 253 257 10.1016/j.jemermed.2005.01.025 16183442 (Pubitemid 41383845)
    • (2005) Journal of Emergency Medicine , vol.29 , Issue.3 , pp. 253-257
    • Wackett, A.1    Anderson, K.2    Thode, H.3
  • 18
    • 34250643975 scopus 로고    scopus 로고
    • Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills
    • DOI 10.1111/j.1365-2044.2007.05069.x
    • Evaluation of four manikins as simulators for teaching airway management procedures specified in the Difficult Airway Society guidelines, and other advanced airway skills. GM Jordan J Silsby G Bayley TM Cook Difficult Airway Society, Anaesthesia 2007 62 708 712 10.1111/j.1365-2044.2007.05069.x 17567347 (Pubitemid 46929965)
    • (2007) Anaesthesia , vol.62 , Issue.7 , pp. 708-712
    • Jordan, G.M.1    Silsby, J.2    Bayley, G.3    Cook, T.M.4
  • 19
    • 25444489609 scopus 로고    scopus 로고
    • Evaluation of the airway of the SimMan™ full-scale patient simulator
    • DOI 10.1111/j.1399-6576.2005.00856.x
    • Evaluation of the airway of the SimMan full-scale patient simulator. R Hesselfeldt MS Kristensen LS Rasmussen, Acta Anaesthesiol Scand 2005 49 1339 1345 10.1111/j.1399-6576.2005.00856.x 16146473 (Pubitemid 41375061)
    • (2005) Acta Anaesthesiologica Scandinavica , vol.49 , Issue.9 , pp. 1339-1345
    • Hesselfeldt, R.1    Kristensen, M.S.2    Rasmussen, L.S.3
  • 20
    • 0027987781 scopus 로고
    • The effect on laryngoscopy of different cervical spine immobilisation techniques
    • DOI 10.1111/j.1365-2044.1994.tb04254.x
    • The effect of laryngoscopy of different cervical spine immobilisation techniques. KJ Heath, Anaesthesia 1994 49 843 845 10.1111/j.1365-2044.1994. tb04254.x 7802175 (Pubitemid 24315042)
    • (1994) Anaesthesia , vol.49 , Issue.10 , pp. 843-845
    • Heath, K.J.1
  • 21
    • 13244271956 scopus 로고    scopus 로고
    • Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway
    • 15717709
    • Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway. BM Wahlen E Gercek, Eur J Anaesthesiol 2004 21 907 913 15717709
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 907-913
    • Wahlen, B.M.1    Gercek, E.2
  • 22
    • 21344439841 scopus 로고    scopus 로고
    • Movement of the upper cervical spine during laryngoscopy: A comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope
    • DOI 10.1111/j.1365-2044.2005.04224.x
    • Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope. C Rudolph JP Schneider J Wallenborn L Schaffranietz, Anaesthesia 2005 60 668 672 10.1111/j.1365-2044.2005.04224.x 15960717 (Pubitemid 40908992)
    • (2005) Anaesthesia , vol.60 , Issue.7 , pp. 668-672
    • Rudolph, C.1    Scheider, J.P.2    Wallenborn, J.3    Schaffranietz, L.4
  • 23
    • 0030329531 scopus 로고    scopus 로고
    • Clinical experiences with fiber optic intubation with the Bonfils intubation fiberscope
    • 9044555
    • [Clinical experiences with fiber optic intubation with the Bonfils intubation fiberscope]. C Rudolph M Schlender, Anaesthesiol Reanim 1996 21 127 130 9044555
    • (1996) Anaesthesiol Reanim , vol.21 , pp. 127-130
    • Rudolph, C.1    Schlender, M.2
  • 24
    • 0026350145 scopus 로고
    • Management of the difficult adult airway. with special emphasis on awake tracheal intubation
    • 10.1097/00000542-199111000-00041 1824555
    • Management of the difficult adult airway. With special emphasis on awake tracheal intubation. JL Benumof, Anesthesiology 1991 75 1087 1110 10.1097/00000542-199111000-00041 1824555
    • (1991) Anesthesiology , vol.75 , pp. 1087-1110
    • Benumof, J.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.