메뉴 건너뛰기




Volumn 11, Issue 2, 2011, Pages 1418-1432

A novel method for in-situ monitoring of local voltage, temperature and humidity distributions in fuel cells using flexible multi-functional micro sensors

Author keywords

Flexible multi functional micro sensors; MEMS; PEMFC

Indexed keywords

PROTON;

EID: 79952084691     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s110201418     Document Type: Article
Times cited : (25)

References (20)
  • 1
    • 33645677018 scopus 로고    scopus 로고
    • Detection of membrane drying, fuel cell flooding and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy
    • Le Canut, J.M.; Abouatallah, R.M.; Harrington, D.A. Detection of membrane drying, fuel cell flooding and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy. J. Electrochem. Soc. 2006, 153, A857-A864.
    • (2006) J. Electrochem. Soc. , vol.153
    • le Canut, J.M.1    Abouatallah, R.M.2    Harrington, D.A.3
  • 2
    • 57249095667 scopus 로고    scopus 로고
    • Novel in situ measurements of relative humidity in a polymer electrolyte membrane fuel cell
    • Hinds, G.; Stevens, M.; Wilkinson, J.; de Podesta, M.; Bell, S. Novel in situ measurements of relative humidity in a polymer electrolyte membrane fuel cell. J. Power Sources 2009, 186, 52-57.
    • (2009) J. Power Sources , vol.186 , pp. 52-57
    • Hinds, G.1    Stevens, M.2    Wilkinson, J.3    de Podesta, M.4    Bell, S.5
  • 3
    • 33646916589 scopus 로고    scopus 로고
    • Water flooding and two-phase flow in cathode channels of proton exchange membrane fuel cells
    • Liu, X.; Guo, H.; Ma, C. Water flooding and two-phase flow in cathode channels of proton exchange membrane fuel cells. J. Power Sources 2006, 156, 267-280.
    • (2006) J. Power Sources , vol.156 , pp. 267-280
    • Liu, X.1    Guo, H.2    Ma, C.3
  • 4
    • 78649495770 scopus 로고    scopus 로고
    • Liquid water flooding process in proton exchange membrane fuel cell cathode with straight parallel channels and porous layer
    • Wang, X.; Zhou, B. Liquid water flooding process in proton exchange membrane fuel cell cathode with straight parallel channels and porous layer. J. Power Sources 2011, 196, 1776-1794.
    • (2011) J. Power Sources , vol.196 , pp. 1776-1794
    • Wang, X.1    Zhou, B.2
  • 6
    • 33750285503 scopus 로고    scopus 로고
    • In situ investigation of water transport in an operating PEM fuel cell using neutron radiography: Part 1-Experimental method and serpentine flow field results
    • Trabold, T.A.; Owejan, J.P.; Jacobson, D.L.; Arif, M.; Huffman, P.R. In situ investigation of water transport in an operating PEM fuel cell using neutron radiography: Part 1-Experimental method and serpentine flow field results. Int. J. Heat Mass Transfer 2006, 49, 4712-4720.
    • (2006) Int. J. Heat Mass Transfer , vol.49 , pp. 4712-4720
    • Trabold, T.A.1    Owejan, J.P.2    Jacobson, D.L.3    Arif, M.4    Huffman, P.R.5
  • 7
    • 43049117514 scopus 로고    scopus 로고
    • PEM fuel cell relative humidity (RH) and its effect on performance at high temperatures
    • Zhang, J.; Tang, Y.; Song, C.; Xia, Z.; Li, H.; Wang, H.; Zhang, J. PEM fuel cell relative humidity (RH) and its effect on performance at high temperatures. Electrochim. Acta 2008, 53, 5315-5321.
    • (2008) Electrochim. Acta , vol.53 , pp. 5315-5321
    • Zhang, J.1    Tang, Y.2    Song, C.3    Xia, Z.4    Li, H.5    Wang, H.6    Zhang, J.7
  • 8
    • 66349111261 scopus 로고    scopus 로고
    • In-fibre Bragg Grating sensors for distributed temperature measurement in a polymer electrolyte membrane fuel cell
    • David, N.A.; Wild, P.M.; Hu, J.; Djilali, N. In-fibre Bragg Grating sensors for distributed temperature measurement in a polymer electrolyte membrane fuel cell. J. Power Sources 2009, 192, 376-380.
    • (2009) J. Power Sources , vol.192 , pp. 376-380
    • David, N.A.1    Wild, P.M.2    Hu, J.3    Djilali, N.4
  • 9
    • 77950295926 scopus 로고    scopus 로고
    • Design of an optical thermal sensor for proton exchange membrane fuel cell temperature measurement using phosphor thermometry
    • Inman, K.; Wang, X.; Sangeorzan, B. Design of an optical thermal sensor for proton exchange membrane fuel cell temperature measurement using phosphor thermometry. J. Power Sources 2010, 195, 4753-4757.
    • (2010) J. Power Sources , vol.195 , pp. 4753-4757
    • Inman, K.1    Wang, X.2    Sangeorzan, B.3
  • 11
    • 33744466831 scopus 로고    scopus 로고
    • Temperature Distribution on the MEA surface of a PEMFC with serpentine channel flow bed
    • Wang, M.; Guo, H.; Ma, C. Temperature Distribution on the MEA surface of a PEMFC with serpentine channel flow bed. J. Power Sources 2006, 157, 181-187.
    • (2006) J. Power Sources , vol.157 , pp. 181-187
    • Wang, M.1    Guo, H.2    Ma, C.3
  • 12
    • 58149144586 scopus 로고    scopus 로고
    • Characterization of flooding and two-phase flow in polymer electrolyte membrane fuel cell stacks
    • Karimi, G.; Jafarpour, F.; Li, X. Characterization of flooding and two-phase flow in polymer electrolyte membrane fuel cell stacks. J. Power Sources 2009, 187, 156-164.
    • (2009) J. Power Sources , vol.187 , pp. 156-164
    • Karimi, G.1    Jafarpour, F.2    Li, X.3
  • 13
    • 34247588554 scopus 로고    scopus 로고
    • Numerical studies on rib & channel dimension of flow-field on PEMFC performance
    • Shimpalee, S.; Zee, J.W.V. Numerical studies on rib & channel dimension of flow-field on PEMFC performance. Int. J. Hydrogen Energy 2007, 32, 842-856.
    • (2007) Int. J. Hydrogen Energy , vol.32 , pp. 842-856
    • Shimpalee, S.1    Zee, J.W.V.2
  • 14
    • 44149089335 scopus 로고    scopus 로고
    • Embedded flexible micro-sensors in MEA for measuring temperature and humidity in a micro-fuel cell
    • Lee, C.Y.; Hsieh, W.J.; Wu, G.W. Embedded flexible micro-sensors in MEA for measuring temperature and humidity in a micro-fuel cell. J. Power Sources 2008, 181, 237-243.
    • (2008) J. Power Sources , vol.181 , pp. 237-243
    • Lee, C.Y.1    Hsieh, W.J.2    Wu, G.W.3
  • 15
    • 77956342427 scopus 로고    scopus 로고
    • In-situ monitoring of internal local temperature and voltage of proton exchange membrane fuel cells
    • Lee, C.Y.; Fan, W.Y.; Hsieh, W.J. In-situ monitoring of internal local temperature and voltage of proton exchange membrane fuel cells. Sensors 2010, 10, 6395-6405.
    • (2010) Sensors , vol.10 , pp. 6395-6405
    • Lee, C.Y.1    Fan, W.Y.2    Hsieh, W.J.3
  • 17
    • 77950520071 scopus 로고    scopus 로고
    • Capacitive humidity-sensitivity of carbonized silicon nanoporous pillar array
    • Wang, H.Y.; Li, X.J. Capacitive humidity-sensitivity of carbonized silicon nanoporous pillar array. Mater. Lett. 2010, 64, 1268-1270.
    • (2010) Mater. Lett. , vol.64 , pp. 1268-1270
    • Wang, H.Y.1    Li, X.J.2
  • 19
    • 1542363558 scopus 로고    scopus 로고
    • High-sensitivity capacitive humidity sensor using 3-layer patterned polyimide sensing film
    • Laconte, J.; Wilmart, V.; Flandre, D.; Raskin, J.P. High-sensitivity capacitive humidity sensor using 3-layer patterned polyimide sensing film. Sensors 2003, 1, 372-377.
    • (2003) Sensors , vol.1 , pp. 372-377
    • Laconte, J.1    Wilmart, V.2    Flandre, D.3    Raskin, J.P.4
  • 20
    • 16244372660 scopus 로고    scopus 로고
    • Porous silicon-based humidity sensor with interdigital electrodes and internal heaters
    • Fürjes, P.; Kovács, A.; Dücsö, C.; Ádám, M.; Müller, B.; Mescheder, U. Porous silicon-based humidity sensor with interdigital electrodes and internal heaters. Sens. Actuat. B 2003, 95, 140-144.
    • (2003) Sens. Actuat. B , vol.95 , pp. 140-144
    • Fürjes, P.1    Kovács, A.2    Dücsö, C.3    Ádám, M.4    Müller, B.5    Mescheder, U.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.