메뉴 건너뛰기




Volumn 165, Issue 1, 2011, Pages 2-7

Capacitive tactile sensor array for touch screen application

Author keywords

Capacitive sensor; Flexible device; Multi touch; Tactile sensor; Touch screen

Indexed keywords

CAPACITIVE SENSOR; FLEXIBLE DEVICE; MULTI-TOUCH; TACTILE SENSORS; TOUCH SCREEN;

EID: 79951773303     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2009.12.031     Document Type: Conference Paper
Times cited : (202)

References (17)
  • 8
    • 0035806046 scopus 로고    scopus 로고
    • Monolithically integrated, flexible display of polymer-dispersed liquid crystal driven by rubber-stamped organic thin-film transistors
    • DOI 10.1063/1.1377312
    • P. Mach, S.J. Rodriguez, R. Nortrup, P. Wiltzius, and J.A. Rogers Monolithically integrated, flexible display of polymer-dispersed liquid crystal driven by rubber-stamped organic thin-film transistors Appl. Phys. Lett. 78 2001 3592 3594 (Pubitemid 33599251)
    • (2001) Applied Physics Letters , vol.78 , Issue.23 , pp. 3592-3594
    • Mach, P.1    Rodriguez, S.J.2    Nortrup, R.3    Wiltzius, P.4    Rogers, J.A.5
  • 9
    • 33845517787 scopus 로고    scopus 로고
    • A flexible polymer tactile sensor: Fabrication and modular expandability for large area deployment
    • DOI 10.1109/JMEMS.2006.886021
    • H.-K. Lee, S.-I. Chang, and E. Yoon A flexible polymer tactile sensor: fabrication and modular expandability for large area deployment J. Microelectromech. Syst. 15 2006 1681 1686 (Pubitemid 44921787)
    • (2006) Journal of Microelectromechanical Systems , vol.15 , Issue.6 , pp. 1681-1686
    • Lee, H.-K.1    Chang, S.-I.2    Yoon, E.3
  • 10
    • 0038353936 scopus 로고    scopus 로고
    • Development of polyimide flexible tactile sensor skin
    • J. Engel, J. Chen, and C. Liu Development of polyimide flexible tactile sensor skin J. Micromech. Microeng. 13 2003 359 366
    • (2003) J. Micromech. Microeng. , vol.13 , pp. 359-366
    • Engel, J.1    Chen, J.2    Liu, C.3
  • 11
    • 0042431781 scopus 로고    scopus 로고
    • Tactile sensing technology for minimal access surgery - A review
    • M.E.H. Eltaib, and J.R. Hewit Tactile sensing technology for minimal access surgery - a review Mechatronics 13 2003 1163 1177
    • (2003) Mechatronics , vol.13 , pp. 1163-1177
    • Eltaib, M.E.H.1    Hewit, J.R.2
  • 12
    • 0002575093 scopus 로고    scopus 로고
    • Tactile sensing for mechatronics - A state of the art survey
    • PII S0957415898000452
    • M.H. Lee, and H.R. Nicholls Tactile sensing for mechatronics: a state of art survey Mechatronics 9 1999 1 31 (Pubitemid 129709244)
    • (1999) Mechatronics , vol.9 , Issue.1 , pp. 1-31
    • Lee, M.H.1    Nicholls, H.R.2
  • 15
    • 4544243069 scopus 로고    scopus 로고
    • A tactile sensor sheet using pressure conductive rubber with electrical-wires stitched method
    • M. Shimojo, A. Namiki, M. Ishikawa, and R. Makino A tactile sensor sheet using pressure conductive rubber with electrical-wires stitched method IEEE Sens. J. 4 2004 589 595
    • (2004) IEEE Sens. J. , vol.4 , pp. 589-595
    • Shimojo, M.1    Namiki, A.2    Ishikawa, M.3    Makino, R.4
  • 16
    • 0034467107 scopus 로고    scopus 로고
    • Traction stress sensor array for use in high-resolution robotic tactile imaging
    • DOI 10.1109/84.896763
    • B.J. Kane, M.R. Cutkosky, and G.T.A. Kovacs A traction stress sensor array for use in high-resolution robotic tactile imaging J. Microelectromech. Syst. 9 2000 425 434 (Pubitemid 32169004)
    • (2000) Journal of Microelectromechanical Systems , vol.9 , Issue.4 , pp. 425-434
    • Kane, B.J.1    Cutkosky, M.R.2    Kovacs, G.T.A.3
  • 17
    • 33745614052 scopus 로고    scopus 로고
    • Design and microfabrication of a hybrid piezoelectric-capacitive tactile sensor
    • DOI 10.1108/02602280610675465
    • J. Dargahi, N.P. Rao, and S. Sokhanvar Design and microfabrication of a hybrid piezoelectric-capacitive tactile sensor Sens. Rev. 26 2006 186 192 (Pubitemid 43992736)
    • (2006) Sensor Review , vol.26 , Issue.3 , pp. 186-192
    • Dargahi, J.1    Rao, N.P.2    Sokhanvar, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.