Volumn 58, Issue 1 PART 1, 2011, Pages 58-65

NEMA NU 4-2008 performance measurements of two commercial small-animal PET scanners: ClearPET and rPET-1

Author keywords

Image quality assessment; performance evaluation; PET; small animal imagers

Indexed keywords

1-SYSTEMS; ASSESSMENT PROCEDURE; AXIAL FIELD OF VIEWS; CLEARPET; COUNTING RATES; DETECTOR MODULE; FIELD OF VIEWS; GEOMETRICAL DIFFERENCES; IMAGE QUALITY ASSESSMENT; MADRID , SPAIN; NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONS; PERFORMANCE EVALUATION; PERFORMANCE MEASUREMENTS; PET; POSITRON EMISSION TOMOGRAPHY SCANNERS; RECOVERY COEFFICIENTS; SCATTER FRACTIONS; SMALL ANIMAL PET; SMALL VARIATIONS; SMALL-ANIMAL; SPATIAL RESOLUTION; TRANSAXIAL; TRANSVERSE AXIS;

EID: 79951682532     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2010.2072935     Document Type: Article
Times cited : (33)

References (24)
  • 2
    • 0035222861 scopus 로고    scopus 로고
    • Use of positron emission tomography in animal research
    • S. R. Cherry and S. S. Gambhir, "Use of positron emission tomography in animal research," Inst. Lab. Animal Res. J., vol. 42, pp. 219-232, 2001. (Pubitemid 33708710)
    • (2001) ILAR Journal , vol.42 , Issue.3 , pp. 219-232
    • Cherry, S.R.1    Gambhir, S.S.2
  • 3
    • 39049175635 scopus 로고    scopus 로고
    • Positron emission tomography imaging as a key enabling technology in drug development
    • T. J. McCarthy, "Positron emission tomography imaging as a key enabling technology in drug development," in Proc. Ernst Schering Res. Found. Workshop, 2007, vol. 62, no. 3, pp. 29-39.
    • (2007) Proc. Ernst Schering Res. Found. Workshop , vol.62 , Issue.3 , pp. 29-39
    • McCarthy, T.J.1
  • 5
    • 67649156801 scopus 로고    scopus 로고
    • Development of an optimised LSO/LuYAP phoswich detector head for the ClearPET camera
    • Oct.
    • J. B. Mosset et al., "Development of an optimised LSO/LuYAP phoswich detector head for the ClearPET camera," in Proc. IEEE Nuclear Science Symp. and Medical Imaging Conf. Rec., Oct. 2005, vol. 3, pp. 1641-1644.
    • (2005) Proc. IEEE Nuclear Science Symp. and Medical Imaging Conf. Rec. , vol.3 , pp. 1641-1644
    • Mosset, J.B.1
  • 6
    • 33846572458 scopus 로고    scopus 로고
    • RPET detectors design and data processing
    • DOI 10.1109/NSSMIC.2005.1596934, 1596934, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • J. J. Vaquero, E. Lage, L. Ricon, M. Abella, E. Vicente, and M. Desco, "rPET detectors design and data processing," in Proc. IEEE Nuclear Science Symp. and Medical Imaging Conf. Rec., Oct. 2005, vol. 5, pp. 2885-2889. (Pubitemid 46172339)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2885-2889
    • Vaquero, J.J.1    Lage, E.2    Ricon, L.3    Abella, M.4    Vicente, E.5    Desco, M.6
  • 10
    • 62449092307 scopus 로고    scopus 로고
    • Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards
    • Q. Bao, D. Newport, M. Chen, D. B. Stout, and A. F. Chatziioannou, "Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards," J. Nucl. Med., vol. 50, pp. 401-408, 2009.
    • (2009) J. Nucl. Med. , vol.50 , pp. 401-408
    • Bao, Q.1    Newport, D.2    Chen, M.3    Stout, D.B.4    Chatziioannou, A.F.5
  • 11
    • 77950660371 scopus 로고    scopus 로고
    • Performance evaluation of small animal PET system using NEMA standards
    • (abstract)
    • C. Wietholt, I. Hsiao, K. Lin, Y. Chung, C. Chen, and T. Yen, "Performance evaluation of small animal PET system using NEMA standards," J. Nucl. Med., vol. 49, p. 119, 2008, (abstract).
    • (2008) J. Nucl. Med. , vol.49 , pp. 119
    • Wietholt, C.1    Hsiao, I.2    Lin, K.3    Chung, Y.4    Chen, C.5    Yen, T.6
  • 12
    • 77950678626 scopus 로고    scopus 로고
    • Performance evaluation of a PEM scanner using the NEMA NU 4-2008 small animal PET standards
    • Feb.
    • W. Luo, E. Anashkin, and C. G. Matthews, "Performance evaluation of a PEM scanner using the NEMA NU 4-2008 small animal PET standards," IEEE Trans. Nucl. Sci., vol. 57, no. 1, pp. 94-103, Feb. 2010.
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.1 , pp. 94-103
    • Luo, W.1    Anashkin, E.2    Matthews, C.G.3
  • 13
    • 70350635839 scopus 로고    scopus 로고
    • Design and performance evaluation of a coplanar multimodality scanner for rodent imaging
    • E. Lage et al., "Design and performance evaluation of a coplanar multimodality scanner for rodent imaging," Phys. Med. Biol., vol. 54, pp. 5427-5441, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5427-5441
    • Lage, E.1
  • 14
    • 0142063370 scopus 로고    scopus 로고
    • Design optimization of the PMT-ClearPET prototypes based on simulation with GEANT3
    • Oct.
    • U. Heinrichs, U. Pietrzyk, and K. Ziemons, "Design optimization of the PMT-ClearPET prototypes based on simulation with GEANT3," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1428-1432, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1428-1432
    • Heinrichs, U.1    Pietrzyk, U.2    Ziemons, K.3
  • 15
    • 0028700063 scopus 로고    scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag., vol. 13, pp. 601-609, 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 16
    • 33746374426 scopus 로고    scopus 로고
    • The data acquisition system of ClearPET neuro - A small animal PET scanner
    • DOI 10.1109/TNS.2006.875051, 1644928
    • M. Streun, G. Brandenburg, H. Larue, C. Parl, and K. Ziemons, "The data acquisition system of ClearPET Neuro-A small animal PET scanner," IEEE Trans. Nucl. Sci., vol. 53, no. 3, pp. 700-703, Jun. 2006. (Pubitemid 44109334)
    • (2006) IEEE Transactions on Nuclear Science , vol.53 , Issue.3 , pp. 700-703
    • Streun, M.1    Brandenburg, G.2    Larue, H.3    Parl, C.4    Ziemons, K.5
  • 17
    • 0024610693 scopus 로고
    • Analytic 3D image reconstruction using all detected events
    • Feb.
    • P. E. Kinahan and J. G. Rogers, "Analytic 3D image reconstruction using all detected events," IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 964-968, Feb. 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.36 , Issue.1 , pp. 964-968
    • Kinahan, P.E.1    Rogers, J.G.2
  • 19
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in threedimensional PET," J. Nucl. Med., vol. 28, pp. 1717-1724, 1987. (Pubitemid 17160290)
    • (1987) Journal of Nuclear Medicine , vol.28 , Issue.11 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 20
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • S. C. Strother, M. E. Casey, and E. J. Hoffman, "Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts," IEEE Trans. Nucl. Sci., vol. 37, no. 2, pp. 783-788, Apr. 1990. (Pubitemid 20713969)
    • (1990) IEEE Transactions on Nuclear Science , vol.37 , Issue.PART 2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 21
    • 19744363131 scopus 로고    scopus 로고
    • Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET
    • S. Yamamoto, H. Horii, M. Hurutani, K. Matsumoto, and M. Senda, "Investigation of single, random, and true counts from natural radioactivity in LSO-based clinical PET," Ann. Nucl. Med., vol. 19, pp. 109-114, 2005. (Pubitemid 40745693)
    • (2005) Annals of Nuclear Medicine , vol.19 , Issue.2 , pp. 109-114
    • Yamamoto, S.1    Horii, H.2    Hurutani, M.3    Matsumoto, K.4    Senda, M.5
  • 23
    • 33748566788 scopus 로고    scopus 로고
    • FIRST: Fast Iterative Reconstruction Software for (PET) tomography
    • DOI 10.1088/0031-9155/51/18/007, PII S0031915506176101, 007
    • J. L. Herraiz, S. España, J. J. Vaquero, M. Desco, and J. M. Udías, "FIRST: Fast iterative reconstruction software for (PET) tomography," Phys. Med. Biol., vol. 51, pp. 4547-4565, 2006. (Pubitemid 44362514)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.18 , pp. 4547-4565
    • Herraiz, J.L.1    Espana, S.2    Vaquero, J.J.3    Desco, M.4    Udias, J.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.