메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 2662-2666

Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: Phantom studies

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE QUALITY; ITERATIVE METHODS; MAPS; OPTICAL COLLIMATORS; OPTIMIZATION; PARAMETER ESTIMATION;

EID: 11844304121     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (58)

References (10)
  • 1
    • 0026669029 scopus 로고
    • Fast maximum-likelihood reconstruction
    • Sept
    • TR Miller, JW Wallis, "Fast maximum-likelihood reconstruction, " J. Nucl Med, 33: 9, 1710-1711 (Sept 1992).
    • (1992) J. Nucl Med , vol.33 , Issue.9 , pp. 1710-1711
    • Miller, T.R.1    Wallis, J.W.2
  • 2
    • 0027367463 scopus 로고
    • Rapidly converging iterative reconstruction algorithm in single-photon emission computed tomography
    • Oct
    • JW Wallis, TR Miller, "Rapidly converging iterative reconstruction algorithm in single-photon emission computed tomography," J Nucl. Med, 34: 10, 1793-1800 (Oct 1993).
    • (1993) J Nucl. Med , vol.34 , Issue.10 , pp. 1793-1800
    • Wallis, J.W.1    Miller, T.R.2
  • 3
    • 11844286219 scopus 로고    scopus 로고
    • Fast projection and backprojection with modeling of attenuation and depth dependent resolution for iterative SPECT reconstruction
    • May abstr.
    • EG Hawman, JW Wallis, "Fast projection and backprojection with modeling of attenuation and depth dependent resolution for iterative SPECT reconstruction," J. Nucl. Med., 39: 5, 79p (May 1998) abstr.
    • (1998) J. Nucl. Med. , vol.39 , Issue.5
    • Hawman, E.G.1    Wallis, J.W.2
  • 5
    • 0032137663 scopus 로고    scopus 로고
    • Slab-by-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithms
    • Aug
    • C Bai, OL Zeng, GT Gullberg. et al., "Slab-by-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithms," IEEE Trans Nucl Sci, 45:4,2168-2172 (Aug 1998).
    • (1998) IEEE Trans Nucl Sci , vol.45 , Issue.4 , pp. 2168-2172
    • Bai, C.1    Zeng, O.L.2    Gullberg, G.T.3
  • 6
    • 0012620474 scopus 로고    scopus 로고
    • Selection of task-dependent diffusion filters for the post processing of SPECT images
    • FJ Beekman, ETP Slijpen, WJ Niessen," Selection of task-dependent diffusion filters for the post processing of SPECT images", Phys. Med. Biol. 33 (1998), p.712-730
    • (1998) Phys. Med. Biol. , vol.33 , pp. 712-730
    • Beekman, F.J.1    Slijpen, E.T.P.2    Niessen, W.J.3
  • 9
    • 3142732002 scopus 로고    scopus 로고
    • The effect of true 3D beam modeled reconstructions on SPECT myocardial defect extent quantification with and without Profile attenuation correction - A phantom study
    • May (abstr)
    • JN Kritzman, EP Ficaro, AH Vija, EG Hawman, JC Engdahl, JR Corbett, "The effect of true 3D beam modeled reconstructions on SPECT myocardial defect extent quantification with and without Profile attenuation correction - A phantom study," J Nucl Med, 44: 5, 140p (May 2003) (abstr)
    • (2003) J Nucl Med , vol.44 , Issue.5
    • Kritzman, J.N.1    Ficaro, E.P.2    Vija, A.H.3    Hawman, E.G.4    Engdahl, J.C.5    Corbett, J.R.6
  • 10
    • 3142732002 scopus 로고    scopus 로고
    • The effect of true 3D beam modeled reconstructions on normal SPECT perfusion databases with and without Profile attenuation correction
    • May (abstr.)
    • JN Kritzman, EP Ficaro, AH Vija, EG Hawman, JC Engdahl, JR Corbett, "The effect of true 3D beam modeled reconstructions on normal SPECT perfusion databases with and without Profile attenuation correction," J Nucl Med, 44: 5, 203p (May 2003) (abstr.)
    • (2003) J Nucl Med , vol.44 , Issue.5
    • Kritzman, J.N.1    Ficaro, E.P.2    Vija, A.H.3    Hawman, E.G.4    Engdahl, J.C.5    Corbett, J.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.