Volumn 14, Issue 4 SPEC. ISS., 2007, Pages 555-565

Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies

Author keywords

filtered backprojection; Single photon emission computed tomography; wide beam reconstruction

Indexed keywords

TETROFOSMIN TC 99M;

EID: 34547418771     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nuclcard.2007.04.022     Document Type: Article
Times cited : (142)

References (12)
  • 1
    • 34547445647 scopus 로고
    • Technetium-99m-sestamibi myocardial perfusion imaging: comparison between a short (8 minutes) and standard (21 minutes) data acquisition time in diagnosis of coronary artery disease
    • [abstract]
    • Taillefer R., Primeau M., Costi P., Lambert R., Leveille J., and Latour Y. Technetium-99m-sestamibi myocardial perfusion imaging: comparison between a short (8 minutes) and standard (21 minutes) data acquisition time in diagnosis of coronary artery disease. [abstract]. J Nucl Med 33 (1992) 855
    • (1992) J Nucl Med , vol.33 , pp. 855
    • Taillefer, R.1    Primeau, M.2    Costi, P.3    Lambert, R.4    Leveille, J.5    Latour, Y.6
  • 3
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L.A., and Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1 (1982) 113-122
    • (1982) IEEE Trans Med Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 4
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K., and Carson R. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8 (1984) 306-316
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 5
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H.M., and Larkin R.S. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 13 (1994) 601-609
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 6
    • 0001579739 scopus 로고
    • Implementation of simultaneous attenuation and detector response correction in SPECT
    • Tsui B.M.W., Hu H.B., Gilland D.R., and Gullberg G.T. Implementation of simultaneous attenuation and detector response correction in SPECT. IEEE Trans Nucl Sci 35 (1988) 778-783
    • (1988) IEEE Trans Nucl Sci , vol.35 , pp. 778-783
    • Tsui, B.M.W.1    Hu, H.B.2    Gilland, D.R.3    Gullberg, G.T.4
  • 7
    • 0031807137 scopus 로고    scopus 로고
    • Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT
    • Hutton B.F., and Lau Y.H. Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT. Phys Med Biol 43 (1998) 1679-1693
    • (1998) Phys Med Biol , vol.43 , pp. 1679-1693
    • Hutton, B.F.1    Lau, Y.H.2
  • 9
    • 11844304121 scopus 로고    scopus 로고
    • Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: phantom studies
    • Vija H., Hawman E.G., and Engdahl J.C. Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: phantom studies. Conference record, IEEE MIC (2003)
    • (2003) Conference record, IEEE MIC
    • Vija, H.1    Hawman, E.G.2    Engdahl, J.C.3
  • 11
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • Metz C.E., Atkins F.B., and Beck R.N. The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol 25 (1980) 1059-1070
    • (1980) Phys Med Biol , vol.25 , pp. 1059-1070
    • Metz, C.E.1    Atkins, F.B.2    Beck, R.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.