메뉴 건너뛰기




Volumn 56, Issue 4, 2011, Pages 903-918

Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4

Author keywords

[No Author keywords available]

Indexed keywords

LINEAR ACCELERATORS; PARTICLE BEAMS; PHASE SPACE METHODS; PHOTOELECTRONS; PHOTONS; RADIOTHERAPY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY;

EID: 79551699417     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/4/002     Document Type: Article
Times cited : (92)

References (41)
  • 1
    • 0038377458 scopus 로고    scopus 로고
    • Geant4 - A simulation toolkit
    • Agostinelli S et al 2003 Geant4 - a simulation toolkit Nucl. Instrum. Methods A 506 250-303
    • (2003) Nucl. Instrum. Methods A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 2
    • 34447344115 scopus 로고    scopus 로고
    • Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE)
    • DOI 10.1118/1.2736778
    • Ali E S M and Rogers D W O 2007 Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahl (Pubitemid 47055749)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2143-2154
    • Ali, E.S.M.1    Rogers, D.W.O.2
  • 3
    • 33645696556 scopus 로고    scopus 로고
    • Geant4 developments and applications
    • Allison J et al 2006 Geant4 developments and applications IEEE Trans. Nucl. Sci. 53 270-8
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , pp. 270-278
    • Allison, J.1
  • 7
    • 1642308605 scopus 로고    scopus 로고
    • Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics
    • DOI 10.1118/1.1644532
    • Carrier J F, Archambault L and Beaulieu L 2004 Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics Med. Phys. 31 484-92 (Pubitemid 38381008)
    • (2004) Medical Physics , vol.31 , Issue.3 , pp. 484-492
    • Carrier, J.-F.1    Archambault, L.2    Beaulieu, L.3    Roy, R.4
  • 10
    • 12844279815 scopus 로고    scopus 로고
    • Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators
    • DOI 10.1118/1.1829172
    • Cho S H, Vassiliev O N, Lee S, Liu H H, Ibbott G S and Mohan R 2005 Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators Med. Phys. 32 137-48 (Pubitemid 40165525)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 137-148
    • Cho, S.H.1    Vassiliev, O.N.2    Lee, S.3    Liu, H.H.4    Ibbott, G.S.5    Mohan, R.6
  • 11
    • 63849224420 scopus 로고    scopus 로고
    • Physics process level discrimination of detections for GATE: Assessment of contamination in SPECT and spurious activity in PET
    • De Beenhouwer J, Staelens S, Vandenberghe S, Verhaeghe J, Van Holen R, Rault E and Lemahieu I 2009 Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET Med. Phys. 36 1053-60
    • (2009) Med. Phys. , vol.36 , pp. 1053-1060
    • De Beenhouwer, J.1    Staelens, S.2    Vandenberghe, S.3    Verhaeghe, J.4    Van Holen, R.5    Rault, E.6    Lemahieu, I.7
  • 12
    • 0033962673 scopus 로고    scopus 로고
    • Photon beam characterization and modelling for Monte Carlo treatment planning
    • DOI 10.1088/0031-9155/45/2/311, PII S0031915500083482
    • Deng J, Jiang S B, Kapur A, Li J, Pawlicki T and Ma C M 2000 Photon beam characterization and modelling for Monte Carlo treatment planning Phys. Med. Biol. 45 411-27 (Pubitemid 30096772)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.2 , pp. 411-427
    • Deng, J.1    Jiang, S.B.2    Kapur, A.3    Li, J.4    Pawlicki, T.5    Ma, C.-M.6
  • 13
    • 52949136602 scopus 로고    scopus 로고
    • Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies
    • Faddegon B A, Asai M, Perl J, Ross C, Sempau J, Tinslay J and Salvat F 2008 Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies Med. Phys. 35 4308-17
    • (2008) Med. Phys. , vol.35 , pp. 4308-4317
    • Faddegon, B.A.1    Asai, M.2    Perl, J.3    Ross, C.4    Sempau, J.5    Tinslay, J.6    Salvat, F.7
  • 15
    • 67649419084 scopus 로고    scopus 로고
    • Monte Carlo based prediction of radiochromic film response for hadron therapy dosimetry
    • Frisson T, Zahra N, Lautesse P and Sarrut D 2009 Monte Carlo based prediction of radiochromic film response for hadron therapy dosimetry Nucl. Instrum. Methods Phys. Res A 606 749-54
    • (2009) Nucl. Instrum. Methods Phys. Res. A , vol.606 , pp. 749-754
    • Frisson, T.1    Zahra, N.2    Lautesse, P.3    Sarrut, D.4
  • 17
    • 17844366342 scopus 로고    scopus 로고
    • Photon-beam subsource sensitivity to the initial electron-beam parameters
    • DOI 10.1118/1.1884385
    • Fix M K, Keall P J and Siebers J V 2005 Photon-beam subsource sensitivity to the initial electron-beam parameters Med. Phys. 32 1164-75 (Pubitemid 40586800)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 1164-1175
    • Fix, M.K.1    Keall, P.J.2    Siebers, J.V.3
  • 18
    • 9244235511 scopus 로고    scopus 로고
    • Monte Carlo source model for photon beam radiotherapy: Photon source characteristics
    • DOI 10.1118/1.1803431
    • Fix M K, Keall P J, Dawson Kathryn and Siebers Jeffrey V 2004 Monte Carlo source model for photon beam radiotherapy: photon source characteristics Med. Phys. 31 3106-21 (Pubitemid 39552701)
    • (2004) Medical Physics , vol.31 , Issue.11 , pp. 3106-3121
    • Fix, M.K.1    Keall, P.J.2    Dawson, K.3    Siebers, J.V.4
  • 19
    • 0034516672 scopus 로고    scopus 로고
    • Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy
    • DOI 10.1118/1.1318220
    • Fix M K, Keller H, Ruegsegger P and Born E J 2000 Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy Med. Phys. 27 2739-47 (Pubitemid 32063453)
    • (2000) Medical Physics , vol.27 , Issue.12 , pp. 2739-2747
    • Fix, M.K.1    Keller, H.2    Ruegsegger, P.3    Born, E.J.4
  • 22
    • 5744251917 scopus 로고    scopus 로고
    • Gate: A simulation toolkit for PET and SPECT
    • Jan S et al 2004 Gate: a simulation toolkit for PET and SPECT Phys. Med. Biol. 49 4543
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4543
    • Jan, S.1
  • 23
    • 79551708529 scopus 로고    scopus 로고
    • GATE V6: A major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy
    • Jan S et al 2010 GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy Phys. Med. Biol. 56 881-901
    • (2010) Phys. Med. Biol. , vol.56 , pp. 881-901
    • Jan, S.1
  • 24
    • 45849111096 scopus 로고    scopus 로고
    • Physics settings for using the Geant4 toolkit in proton therapy
    • Jarlskog C Z and Paganetti H 2008 Physics settings for using the Geant4 toolkit in proton therapy IEEE 55 1018-24
    • (2008) IEEE , vol.55 , pp. 1018-1024
    • Jarlskog, C.Z.1    Paganetti, H.2
  • 25
    • 22544472679 scopus 로고    scopus 로고
    • On the efficiency of photon beam treatment head simulations
    • DOI 10.1118/1.1943808
    • Kawrakow I 2005 On the efficiency of photon beam treatment head simulations Med. Phys. 32 2320-6 (Pubitemid 41023191)
    • (2005) Medical Physics , vol.32 , Issue.7 , pp. 2320-2326
    • Kawrakow, I.1
  • 26
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • DOI 10.1118/1.1788912
    • Kawrakow I, Rogers D W O and Walters B R B 2004 Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting Med. Phys. 31 2883-98 (Pubitemid 39431018)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.O.2    Walters, B.R.B.3
  • 27
    • 33746608072 scopus 로고    scopus 로고
    • Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc
    • DOI 10.1118/1.2219778
    • Kawrakow I and Walters B R B 2006 Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc Med. Phys. 33 3046-56 (Pubitemid 44154576)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 3046-3056
    • Kawrakow, I.1    Walters, B.R.B.2
  • 28
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 29
    • 33746607672 scopus 로고    scopus 로고
    • Efficient x-ray tube simulations
    • DOI 10.1118/1.2219331
    • Mainegra-Hing E and Kawrakow I 2006 Efficient x-ray tube simulations Med. Phys. 33 2683-90 (Pubitemid 44154540)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2683-2690
    • Mainegra-Hing, E.1    Kawrakow, I.2
  • 30
    • 14644405544 scopus 로고    scopus 로고
    • Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications
    • DOI 10.1118/1.1895796
    • Poon E and Verhaegen F 2005 Accuracy of the photon and electron physics in Geant4 for radiotherapy applications Med. Phys. 32 1696-711 (Pubitemid 40880563)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1696-1711
    • Poon, E.1    Verhaegen, F.2
  • 31
    • 0003295397 scopus 로고    scopus 로고
    • Root: An object-oriented data analysis framework
    • Rademakers F and Brun R 1998 Root: an object-oriented data analysis framework Linux J. Issue 51
    • (1998) Linux J. , Issue.51
    • Rademakers, F.1    Brun, R.2
  • 32
    • 4544225790 scopus 로고    scopus 로고
    • Application of GEANT4 radiation transport toolkit to dose calculations in anthropomorphic phantoms
    • DOI 10.1016/j.apradiso.2004.05.073, PII S0969804304003598
    • Rodrigues P, Trindade A, Peralta L, Alves C, Chaves A and Lopes M C 2004 Application of GEANT4 radiation transport toolkit to dose calculations in anthropomorphic phantoms Appl. Radiat. Isot. 61 1451-61 (Pubitemid 39248975)
    • (2004) Applied Radiation and Isotopes , vol.61 , Issue.6 , pp. 1451-1461
    • Rodrigues, P.1    Trindade, A.2    Peralta, L.3    Alves, C.4    Chaves, A.5    Lopes, M.C.6
  • 34
    • 41449091150 scopus 로고    scopus 로고
    • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations
    • DOI 10.1118/1.2884854
    • Sarrut D and Guigues L 2008 Region-oriented ct image representation for reducing computing time of Monte Carlo simulations Med. Phys. 35 1452-63 (Pubitemid 351457513)
    • (2008) Medical Physics , vol.35 , Issue.4 , pp. 1452-1463
    • Sarrut, D.1    Guigues, L.2
  • 38
    • 45749131116 scopus 로고    scopus 로고
    • Validation of a dose deposited by low-energy photons using GATE/GEANT4
    • DOI 10.1088/0031-9155/53/11/019, PII S0031915508686765
    • Thiam C O, Breton V, Donnarieix D, Habib B and Maigne L 2008 Validation of a dose deposited by low-energy photons using GATE/GEANT4 Phys. Med. Biol. 53 3039-55 (Pubitemid 351868622)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 3039-3055
    • Thiam, C.O.1    Breton, V.2    Donnarieix, D.3    Habib, B.4    Maigne, L.5
  • 39
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • DOI 10.1088/0031-9155/48/21/R01, PII S0031915503332245
    • Verhaegen F and Seuntjens J 2003 Monte Carlo modelling of external radiotherapy photon beams Phys. Med. Biol. 48 R107-64 (Pubitemid 37427947)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.21
    • Verhaegen, F.1    Seuntjens, J.2
  • 40
    • 0036908431 scopus 로고    scopus 로고
    • History by history statistical estimators in the BEAM code system
    • DOI 10.1118/1.1517611
    • Walters B R B, Kawrakow I and Rogers D W O 2002 History by history statistical estimators in the beam code system Med. Phys. 29 2745-52 (Pubitemid 36008467)
    • (2002) Medical Physics , vol.29 , Issue.12 , pp. 2745-2752
    • Walters, B.R.B.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 41
    • 77956873985 scopus 로고    scopus 로고
    • Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation
    • Zahra N, Frisson T, Grevillot L, Lautesse P and Sarrut D 2010 Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation Phys. Medica 26 202-8
    • (2010) Phys. Medica , vol.26 , pp. 202-208
    • Zahra, N.1    Frisson, T.2    Grevillot, L.3    Lautesse, P.4    Sarrut, D.5