메뉴 건너뛰기




Volumn 34, Issue 6, 2007, Pages 2143-2154

Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE)

Author keywords

[No Author keywords available]

Indexed keywords

CHARGED PARTICLES; CLINICAL RESEARCH; DIAGNOSIS; EFFICIENCY; MEDICAL PHYSICS; X RAY PRODUCTION;

EID: 34447344115     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2736778     Document Type: Article
Times cited : (43)

References (31)
  • 3
    • 0000358329 scopus 로고    scopus 로고
    • Monte Carlo simulation of x-ray emission by kilovolt electron bombardment
    • E. Acosta, X. Llovet, E. Coleoni, and J. Riveros, " Monte Carlo simulation of x-ray emission by kilovolt electron bombardment., " J. Appl. Phys. 83, 6038-6049 (1998).
    • (1998) J. Appl. Phys. , vol.83 , pp. 6038-6049
    • Acosta, E.1    Llovet, X.2    Coleoni, E.3    Riveros, J.4
  • 6
    • 0003658847 scopus 로고
    • SLAC-210, Stanford Linear Accelerator Center, Stanford, California
    • R. L. Ford and W. R. Nelson, " The EGS code system-Version 3., " Report SLAC-210, Stanford Linear Accelerator Center, Stanford, California, 1978.
    • (1978) The EGS Code System-Version 3
    • Ford, R.L.1    Nelson, W.R.2
  • 7
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport
    • I. Kawrakow, " Accurate condensed history Monte Carlo simulation of electron transport., " I. EGSnrc, the new EGS4 version, Med. Phys. 27, 485-498 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 8
    • 33746590927 scopus 로고    scopus 로고
    • Electron impact ionization cross sections for EGSnrc
    • I. Kawrakow, " Electron impact ionization cross sections for EGSnrc., " Med. Phys. 29, 1230 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1230
    • Kawrakow, I.1
  • 10
    • 0022113394 scopus 로고
    • Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons
    • S. M. Seltzer and M. J. Berger, " Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons., " Nucl. Instrum. Methods Phys. Res. B 12, 95-134 (1985).
    • (1985) Nucl. Instrum. Methods Phys. Res. B , vol.12 , pp. 95-134
    • Seltzer, S.M.1    Berger, M.J.2
  • 11
    • 27744565298 scopus 로고
    • Bremsstrahlung energy spectra from electrons with kinetic energy from 1 keV to 10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z=1-100
    • S. M. Seltzer and M. J. Berger, " Bremsstrahlung energy spectra from electrons with kinetic energy from 1 keV to 10 GeV incident on screened nuclei and orbital electrons of neutral atoms with Z=1-100., " At. Data Nucl. Data Tables 35, 345-418 (1986).
    • (1986) At. Data Nucl. Data Tables , vol.35 , pp. 345-418
    • Seltzer, S.M.1    Berger, M.J.2
  • 12
    • 0038497894 scopus 로고    scopus 로고
    • An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms
    • L. Ben-Omrane, F. Verhaegen, N. Chahed, and S. Mtimet, " An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms., " Phys. Med. Biol. 48, 1809-1824 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1809-1824
    • Ben-Omrane, L.1    Verhaegen, F.2    Chahed, N.3    Mtimet, S.4
  • 14
    • 0032916167 scopus 로고    scopus 로고
    • Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed spectra with measured spectra
    • M. Bhat, J. Pattison, G. Bibbo, and M. Caon, " Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed spectra with measured spectra., " Med. Phys. 26, 303-309 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 303-309
    • Bhat, M.1    Pattison, J.2    Bibbo, G.3    Caon, M.4
  • 16
    • 0036023824 scopus 로고    scopus 로고
    • Microdosimetric characterisation of 28 kVp MoMo RhRh RhAl WRh and MoRh mammography x-ray spectra
    • F. Verhaegen and I. A. Castellano, " Microdosimetric characterisation of 28 kVp MoMo RhRh RhAl WRh and MoRh mammography x-ray spectra., " Radiat. Prot. Dosim. 99, 393-396 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.99 , pp. 393-396
    • Verhaegen, F.1    Castellano, I.A.2
  • 17
    • 22544476814 scopus 로고    scopus 로고
    • Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays
    • F. Verhaegen, B. Reniers, F. Deblois, S. Devic, J. Seuntjens, and D. Hristov, " Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays., " Phys. Med. Biol. 50, 3555-3569 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 3555-3569
    • Verhaegen, F.1    Reniers, B.2    Deblois, F.3    Devic, S.4    Seuntjens, J.5    Hristov, D.6
  • 18
    • 33845294427 scopus 로고    scopus 로고
    • Investigations of different kilovoltage x-ray energy for three-dimensional converging stereotactic radiotherapy system: Monte Carlo simulation with CT data
    • H. Deloar, " Investigations of different kilovoltage x-ray energy for three-dimensional converging stereotactic radiotherapy system: Monte Carlo simulation with CT data., " Med. Phys. 33, 4635-4642 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 4635-4642
    • Deloar, H.1
  • 19
    • 34447319217 scopus 로고    scopus 로고
    • Monte Carlo Modeling of the Xoft Axxent™ x-ray source
    • R. E. P. Taylor, G. Yegin, and D. W. O. Rogers, " Monte Carlo Modeling of the Xoft Axxent™ x-ray source., " Med. Phys. 33, 2205 (abs) (2006).
    • (2006) Med. Phys. , vol.33 , pp. 2205
    • Taylor, R.E.P.1    Yegin, G.2    Rogers, D.W.O.3
  • 20
    • 33846566263 scopus 로고    scopus 로고
    • Benchmarking BrachyDose: Voxel-based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    • R. E. P. Taylor, G. Yegin, and D. W. O. Rogers, " Benchmarking BrachyDose: voxel-based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters., " Med. Phys. 34, 445-457 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 445-457
    • Taylor, R.E.P.1    Yegin, G.2    Rogers, D.W.O.3
  • 21
    • 0003620648 scopus 로고
    • SLAC-265, Stanford Linear Accelerator Center, Stanford, California
    • W. R. Nelson, H. Hirayama, and D. W. O. Rogers, " The EGS4 Code System., " Report SLAC-265, Stanford Linear Accelerator Center, Stanford, California, 1985.
    • (1985) The EGS4 Code System
    • Nelson, W.R.1    Hirayama, H.2    Rogers, D.W.O.3
  • 23
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • I. Kawrakow, D. W. O. Rogers, and B. Walters, " Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting., " Med. Phys. 31, 2883-2898 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.O.2    Walters, B.3
  • 24
    • 33746607672 scopus 로고    scopus 로고
    • Efficient x-ray tube simulations
    • E. Mainegra-Hing and I. Kawrakow, " Efficient x-ray tube simulations., " Med. Phys. 33, 2683-2690 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 2683-2690
    • Mainegra-Hing, E.1    Kawrakow, I.2
  • 25
    • 0036908431 scopus 로고    scopus 로고
    • History by history statistical estimators in the BEAM code system
    • B. R. B. Walters, I. Kawrakow, and D. W. O. Rogers, " History by history statistical estimators in the BEAM code system., " Med. Phys. 29, 2745-2752 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2745-2752
    • Walters, B.R.B.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 26
    • 22544472679 scopus 로고    scopus 로고
    • On the efficiency of photon beam treatment head calculations
    • I. Kawrakow, " On the efficiency of photon beam treatment head calculations., " Med. Phys. 32, 2320-2326 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2320-2326
    • Kawrakow, I.1
  • 28
    • 36149025042 scopus 로고
    • Bremsstrahlung cross-section formulas and related data
    • H. W. Koch and J. W. Motz, " Bremsstrahlung cross-section formulas and related data., " Rev. Mod. Phys. 31, 920-955 (1959).
    • (1959) Rev. Mod. Phys. , vol.31 , pp. 920-955
    • Koch, H.W.1    Motz, J.W.2
  • 29
    • 33750539751 scopus 로고    scopus 로고
    • Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-Ray source: An electronic brachytherapy source
    • M. J. Rivard, S. D. Davis, L. A. DeWerd, T. W. Rusch, and S. Axelrod, " Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-Ray source: An electronic brachytherapy source., " Med. Phys. 33, 4020-4032 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 4020-4032
    • Rivard, M.J.1    Davis, S.D.2    Dewerd, L.A.3    Rusch, T.W.4    Axelrod, S.5
  • 30
    • 0141963405 scopus 로고    scopus 로고
    • A new approach to geometry modelling of Monte Carlo particle transport: An application to EGS
    • G. Yegin, " A new approach to geometry modelling of Monte Carlo particle transport: an application to EGS., " Nucl. Instrum. Methods Phys. Res. B 211, 331-338 (2003).
    • (2003) Nucl. Instrum. Methods Phys. Res. B , vol.211 , pp. 331-338
    • Yegin, G.1
  • 31
    • 0036130665 scopus 로고    scopus 로고
    • Calculation of nine megavoltage photon beam spectra using the BEAM Monte Carlo code
    • D. Sheikh-Bagheri and D. W. O. Rogers, " Calculation of nine megavoltage photon beam spectra using the BEAM Monte Carlo code., " Med. Phys. 29, 391-402 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.