-
1
-
-
0019435541
-
Osseointegrated Titanium Implants: Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Inchorage in Man
-
10.3109/17453678108991776
-
Albrektsson T. Branemark P.I. Hansson H.A. Lindstrom J. Osseointegrated Titanium Implants: Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Inchorage in Man. Acta Orthopaedica 1981, 52(2):155-170. 10.3109/17453678108991776.
-
(1981)
Acta Orthopaedica
, vol.52
, Issue.2
, pp. 155-170
-
-
Albrektsson, T.1
Branemark, P.I.2
Hansson, H.A.3
Lindstrom, J.4
-
2
-
-
0030155422
-
Loss of Osseointegration Caused by Occlusal Load of Oral Implants. A Clinical and Radiographic Study in Monkeys
-
ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.1996.070208.x
-
Isidor F. Loss of Osseointegration Caused by Occlusal Load of Oral Implants. A Clinical and Radiographic Study in Monkeys. Clin. Oral Implants Res. 1996, 7(2):143-152. ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.1996.070208.x.
-
(1996)
Clin. Oral Implants Res.
, vol.7
, Issue.2
, pp. 143-152
-
-
Isidor, F.1
-
3
-
-
0031061799
-
Histological Evaluation of Peri-Implant Bone at Implants Subjected to Occlusal Overload or Plaque Accumulation
-
ZZZZZZ, 0905-7161, 10.1111/j.1600-0501.1997.tb00001.x
-
Isidor F. Histological Evaluation of Peri-Implant Bone at Implants Subjected to Occlusal Overload or Plaque Accumulation. Clin. Oral Implants Res. 1997, 8(1):1-9. ZZZZZZ, 0905-7161, 10.1111/j.1600-0501.1997.tb00001.x.
-
(1997)
Clin. Oral Implants Res.
, vol.8
, Issue.1
, pp. 1-9
-
-
Isidor, F.1
-
4
-
-
85016033318
-
Mechanical Loading of Branemark Implants Affects Interfacial Bone Modeling and Remodeling
-
ZZZZZZ, 0882-2786
-
Hoshaw S.J. Brunski J.B. Cochran G.V. B. Mechanical Loading of Branemark Implants Affects Interfacial Bone Modeling and Remodeling. Int. J. Oral Maxillofac Implants 1994, 9(3):345-360. ZZZZZZ, 0882-2786.
-
(1994)
Int. J. Oral Maxillofac Implants
, vol.9
, Issue.3
, pp. 345-360
-
-
Hoshaw, S.J.1
Brunski, J.B.2
Cochran, G.V.B.3
-
5
-
-
0023492075
-
Bone Mass and the Mechanostat: A Proposal
-
ANREAK, 0003-276X, 10.1002/ar.1092190104
-
Frost H.M. Bone Mass and the Mechanostat: A Proposal. Anat. Rec. 1987, 219(1):1-9. ANREAK, 0003-276X, 10.1002/ar.1092190104.
-
(1987)
Anat. Rec.
, vol.219
, Issue.1
, pp. 1-9
-
-
Frost, H.M.1
-
6
-
-
18044403181
-
The Influence of Static and Dynamic Loading on Marginal Bone Reactions Around Osseointegrated Implants: An Animal Experimental Study
-
ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.2001.012003207.x
-
Duyck J. Naert I. Rønold H.J. Ellingsen J.E. Oosterwyck H.V. Sloten J.V. The Influence of Static and Dynamic Loading on Marginal Bone Reactions Around Osseointegrated Implants: An Animal Experimental Study. Clin. Oral Implants Res. 2001, 12(3):207-218. ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.2001.012003207.x.
-
(2001)
Clin. Oral Implants Res.
, vol.12
, Issue.3
, pp. 207-218
-
-
Duyck, J.1
Naert, I.2
Rønold, H.J.3
Ellingsen, J.E.4
Oosterwyck, H.V.5
Sloten, J.V.6
-
7
-
-
0035666576
-
A Microstructural Finite Element Simulation of Mechanically Induced Bone Formation
-
JBENDY, 0148-0731, 10.1115/1.1406951
-
Koontz J.T. Charras G.T. Guldberg R.E. A Microstructural Finite Element Simulation of Mechanically Induced Bone Formation. ASME J. Biomech. Eng. 2001, 123(6):607-612. JBENDY, 0148-0731, 10.1115/1.1406951.
-
(2001)
ASME J. Biomech. Eng.
, vol.123
, Issue.6
, pp. 607-612
-
-
Koontz, J.T.1
Charras, G.T.2
Guldberg, R.E.3
-
8
-
-
77955104595
-
Strain Measurement of Pure Titanium Covered With Soft Tissue Using X-Ray Diffraction
-
JBENDY, 0148-0731, 10.1115/1.4000935
-
Fujisaki K. Tadano S. Strain Measurement of Pure Titanium Covered With Soft Tissue Using X-Ray Diffraction. ASME J. Biomech. Eng. 2010, 132(3):031004. JBENDY, 0148-0731, 10.1115/1.4000935.
-
(2010)
ASME J. Biomech. Eng.
, vol.132
, Issue.3
, pp. 031004
-
-
Fujisaki, K.1
Tadano, S.2
-
9
-
-
33845748759
-
Biomechanical Evaluation of a Wide-Diameter Short Dental Implant for Use in Compromised Bone Quality Regions by Finite Element Method
-
10.1115/NANOBIO2006-18022, and ASME, Irvine, CA
-
Chou H.-Y. Muftu S. Bozkaya D. Biomechanical Evaluation of a Wide-Diameter Short Dental Implant for Use in Compromised Bone Quality Regions by Finite Element Method. Frontiers in Biomedical Devices 2006, 39-40. 10.1115/NANOBIO2006-18022, and , ASME, Irvine, CA.
-
(2006)
Frontiers in Biomedical Devices
, pp. 39-40
-
-
Chou, H.-Y.1
Muftu, S.2
Bozkaya, D.3
-
10
-
-
0028253303
-
Wolff's Law and Bone's Structural Adaptations to Mechanical Usage: An Overview for Clinicians
-
ZZZZZZ, 0003-3219
-
Frost H.M. Wolff's Law and Bone's Structural Adaptations to Mechanical Usage: An Overview for Clinicians. Angle Orthod. 1994, 64(3):175-188. ZZZZZZ, 0003-3219.
-
(1994)
Angle Orthod.
, vol.64
, Issue.3
, pp. 175-188
-
-
Frost, H.M.1
-
11
-
-
30344479444
-
Factorial Analysis of Variables Influencing Stress in All-Ceramic Crowns
-
DEMAEP, 0109-5641, 10.1016/j.dental.2005.04.010
-
Rekow E.D. Harsono M. Janal M. Thompson V.P. Zhang G. Factorial Analysis of Variables Influencing Stress in All-Ceramic Crowns. Dent. Mater. 2006, 22(2):125-132. DEMAEP, 0109-5641, 10.1016/j.dental.2005.04.010.
-
(2006)
Dent. Mater.
, vol.22
, Issue.2
, pp. 125-132
-
-
Rekow, E.D.1
Harsono, M.2
Janal, M.3
Thompson, V.P.4
Zhang, G.5
-
12
-
-
75049086035
-
Design Features of a Three-Dimensional Molar Crown and Related Maximum Principal Stress. A Finite Element Model Study
-
DEMAEP, 0109-5641, 10.1016/j.dental.2009.09.009
-
Rafferty B.T. Janal M.N. Zavanelli R.A. Silva N.R. F. A. Rekow E.D. Thompson V.P. Coelho P.G. Design Features of a Three-Dimensional Molar Crown and Related Maximum Principal Stress. A Finite Element Model Study. Dent. Mater. 2010, 26(2):156-163. DEMAEP, 0109-5641, 10.1016/j.dental.2009.09.009.
-
(2010)
Dent. Mater.
, vol.26
, Issue.2
, pp. 156-163
-
-
Rafferty, B.T.1
Janal, M.N.2
Zavanelli, R.A.3
Silva, N.R.F.A.4
Rekow, E.D.5
Thompson, V.P.6
Coelho, P.G.7
-
13
-
-
0022726532
-
The Long-Term Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success
-
ZZZZZZ, 0882-2786
-
Albrektsson T. Zarb G. Worthington P. Eriksson A.R. The Long-Term Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success. Int. J. Oral Maxillofac Implants 1986, 1(1):11-25. ZZZZZZ, 0882-2786.
-
(1986)
Int. J. Oral Maxillofac Implants
, vol.1
, Issue.1
, pp. 11-25
-
-
Albrektsson, T.1
Zarb, G.2
Worthington, P.3
Eriksson, A.R.4
-
14
-
-
0036617178
-
Peri-Implant Bone Tissue Strains in Cases of Dehiscence: A Finite Element Study
-
ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.2002.130314.x
-
Van Oosterwyck H. Duyck J. Vander Sloten J. Van der Perre G. Naert I. Peri-Implant Bone Tissue Strains in Cases of Dehiscence: A Finite Element Study. Clin. Oral Implants Res. 2002, 13(3):327-333. ZZZZZZ, 0905-7161, 10.1034/j.1600-0501.2002.130314.x.
-
(2002)
Clin. Oral Implants Res.
, vol.13
, Issue.3
, pp. 327-333
-
-
Van Oosterwyck, H.1
Duyck, J.2
Vander Sloten, J.3
Van der Perre, G.4
Naert, I.5
-
15
-
-
77955257108
-
Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants-CT-Based Nonlinear, Three-Dimensional Finite Element Analysis
-
Pessoa R.S. Muraru L. Marcantonio-Júnior E. Vaz L.G. Sloten J.V. Duyck J. Jaecques S.V. N. Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants-CT-Based Nonlinear, Three-Dimensional Finite Element Analysis. Clinical Implant Dentistry and Related Research 2010, 12(3):219-234. and pp.
-
(2010)
Clinical Implant Dentistry and Related Research
, vol.12
, Issue.3
, pp. 219-234
-
-
Pessoa, R.S.1
Muraru, L.2
Marcantonio-Júnior, E.3
Vaz, L.G.4
Sloten, J.V.5
Duyck, J.6
Jaecques, S.V.N.7
-
16
-
-
77952528699
-
Multi-Factorial Analysis of Variables Influencing the Bone Loss of an Implant Placed in the Maxilla: Prediction Using FEA and SED Bone Remodeling Algorithm
-
JBMCB5, 0021-9290, 10.1016/j.jbiomech.2009.10.030
-
Lin C.-L. Lin Y.-H. Chang S.-H. Multi-Factorial Analysis of Variables Influencing the Bone Loss of an Implant Placed in the Maxilla: Prediction Using FEA and SED Bone Remodeling Algorithm. J. Biomech. 2010, 43(4):644-651. JBMCB5, 0021-9290, 10.1016/j.jbiomech.2009.10.030.
-
(2010)
J. Biomech.
, vol.43
, Issue.4
, pp. 644-651
-
-
Lin, C.-L.1
Lin, Y.-H.2
Chang, S.-H.3
-
17
-
-
1642471942
-
Role of Mechanical Environment and Implant Design on Bone Tissue Differentiation: Current Knowledge and Future Contexts
-
ZZZZZZ, 0300-5712, 10.1016/j.jdent.2003.09.003
-
Çehreli M. Sahin S. Akça K. Role of Mechanical Environment and Implant Design on Bone Tissue Differentiation: Current Knowledge and Future Contexts. J. Dent. 2004, 32(2):123-132. ZZZZZZ, 0300-5712, 10.1016/j.jdent.2003.09.003.
-
(2004)
J. Dent.
, vol.32
, Issue.2
, pp. 123-132
-
-
Çehreli, M.1
Sahin, S.2
Akça, K.3
-
18
-
-
0038350018
-
The Influence of Functional Forces on the Biomechanics of Implant-Supported Prostheses-A Review
-
ZZZZZZ, 0300-5712, 10.1016/S0300-5712(02)00065-9
-
Şahin S. Çehreli M.C. Yalçin E. The Influence of Functional Forces on the Biomechanics of Implant-Supported Prostheses-A Review. J. Dent. 2002, 30(7-8):271-282. ZZZZZZ, 0300-5712, 10.1016/S0300-5712(02)00065-9.
-
(2002)
J. Dent.
, vol.30
, Issue.7-8
, pp. 271-282
-
-
Şahin, S.1
Çehreli, M.C.2
Yalçin, E.3
-
19
-
-
34548689853
-
Impact of Implant Overloading on the Peri-Implant Bone in Inflamed and Non-Inflamed Peri-Implant Mucosa
-
ZZZZZZ, 0905-7161, 10.1111/j.1600-0501.2007.01374.x
-
Kozlovsky A. Tal H. Laufer B.-Z. Leshem R. Rohrer M.D. Weinreb M. Artzi Z. Impact of Implant Overloading on the Peri-Implant Bone in Inflamed and Non-Inflamed Peri-Implant Mucosa. Clin. Oral Implants Res. 2007, 18(5):601-610. ZZZZZZ, 0905-7161, 10.1111/j.1600-0501.2007.01374.x.
-
(2007)
Clin. Oral Implants Res.
, vol.18
, Issue.5
, pp. 601-610
-
-
Kozlovsky, A.1
Tal, H.2
Laufer, B.-Z.3
Leshem, R.4
Rohrer, M.D.5
Weinreb, M.6
Artzi, Z.7
-
20
-
-
14844290222
-
Three-Dimensional Finite Element Analysis of the Effect of Different Bone Quality on Stress Distribution in an Implant-Supported Crown
-
JPDEAT, 0022-3913, 10.1016/j.prosdent.2004.12.019
-
Sevimay M. Turhan F. Kiliçarslan M.A. Eskitascioglu G. Three-Dimensional Finite Element Analysis of the Effect of Different Bone Quality on Stress Distribution in an Implant-Supported Crown. J. Prosthet. Dent. 2005, 93(3):227-234. JPDEAT, 0022-3913, 10.1016/j.prosdent.2004.12.019.
-
(2005)
J. Prosthet. Dent.
, vol.93
, Issue.3
, pp. 227-234
-
-
Sevimay, M.1
Turhan, F.2
Kiliçarslan, M.A.3
Eskitascioglu, G.4
-
21
-
-
0032038092
-
A Comparative Evaluation of Mandibular Finite Element Models With Different Lengths and Elements for Implant Biomechanics
-
ZZZZZZ, 0305-182X, 10.1111/j.1365-2842.1998.00244.x
-
Teixeira E.R. Sato Y. Akagawa Y. Shindoi N. A Comparative Evaluation of Mandibular Finite Element Models With Different Lengths and Elements for Implant Biomechanics. J. Oral Rehabil. 1998, 25(4):299-303. ZZZZZZ, 0305-182X, 10.1111/j.1365-2842.1998.00244.x.
-
(1998)
J. Oral Rehabil.
, vol.25
, Issue.4
, pp. 299-303
-
-
Teixeira, E.R.1
Sato, Y.2
Akagawa, Y.3
Shindoi, N.4
-
22
-
-
33744969864
-
Effect of Controlled Early Implant Loading on Bone Healing and Bone Mass in Guinea Pigs, as Assessed by Micro-CT and Histology
-
ZZZZZZ, 0909-8836, 10.1111/j.1600-0722.2006.00355.x
-
De Smet E. Jaecques S.V. N. Wevers M. Jansen J.A. Jacobs R. Sloten J.V. Naert I.E. Effect of Controlled Early Implant Loading on Bone Healing and Bone Mass in Guinea Pigs, as Assessed by Micro-CT and Histology. Eur. J. Oral Sci. 2006, 114(3):232-242. ZZZZZZ, 0909-8836, 10.1111/j.1600-0722.2006.00355.x.
-
(2006)
Eur. J. Oral Sci.
, vol.114
, Issue.3
, pp. 232-242
-
-
De Smet, E.1
Jaecques, S.V.N.2
Wevers, M.3
Jansen, J.A.4
Jacobs, R.5
Sloten, J.V.6
Naert, I.E.7
-
23
-
-
33846378773
-
Influence of Controlled Immediate Loading and Implant Design on Peri-Implant Bone Formation
-
JCPEDZ, 0303-6979
-
Katleen V. Ignace N. Liesbet G. Jozef Vander S. Robert P. Joke D. Influence of Controlled Immediate Loading and Implant Design on Peri-Implant Bone Formation. J. Clin. Periodontol. 2007, 34(2):172-181. JCPEDZ, 0303-6979.
-
(2007)
J. Clin. Periodontol.
, vol.34
, Issue.2
, pp. 172-181
-
-
Katleen, V.1
Ignace, N.2
Liesbet, G.3
Jozef Vander, S.4
Robert, P.5
Joke, D.6
-
24
-
-
0026488291
-
Perspectives: Bone's Mechanical Usage Windows
-
BOMIET, 0169-6009, 10.1016/0169-6009(92)90875-E
-
Frost H.M. Perspectives: Bone's Mechanical Usage Windows. Bone Miner. 1992, 19(3):257-271. BOMIET, 0169-6009, 10.1016/0169-6009(92)90875-E.
-
(1992)
Bone Miner.
, vol.19
, Issue.3
, pp. 257-271
-
-
Frost, H.M.1
-
25
-
-
34250200457
-
Effect of Constant Strain Rate, Composed of Varying Amplitude and Frequency, of Early Loading on Peri-Implant Bone (Re)modelling
-
JCPEDZ, 0303-6979, 10.1111/j.1600-051X.2007.01082.x
-
De Smet E. Jaecques S.V. N. Jansen J.J. Walboomers F. Sloten J.V. Naert I.E. Effect of Constant Strain Rate, Composed of Varying Amplitude and Frequency, of Early Loading on Peri-Implant Bone (Re)modelling. J. Clin. Periodontol. 2007, 34(7):618-624. JCPEDZ, 0303-6979, 10.1111/j.1600-051X.2007.01082.x.
-
(2007)
J. Clin. Periodontol.
, vol.34
, Issue.7
, pp. 618-624
-
-
De Smet, E.1
Jaecques, S.V.N.2
Jansen, J.J.3
Walboomers, F.4
Sloten, J.V.5
Naert, I.E.6
-
26
-
-
9944241763
-
Evaluation of Load Transfer Characteristics of Five Different Implants in Compact Bone at Different Load Levels by Finite Elements Analysis
-
JPDEAT, 0022-3913, 10.1016/j.prosdent.2004.07.024
-
Bozkaya D. Muftu S. Muftu A. Evaluation of Load Transfer Characteristics of Five Different Implants in Compact Bone at Different Load Levels by Finite Elements Analysis. J. Prosthet. Dent. 2004, 92(6):523-530. JPDEAT, 0022-3913, 10.1016/j.prosdent.2004.07.024.
-
(2004)
J. Prosthet. Dent.
, vol.92
, Issue.6
, pp. 523-530
-
-
Bozkaya, D.1
Muftu, S.2
Muftu, A.3
-
27
-
-
21344466549
-
A Positive Correlation Between Occlusal Trauma and Peri-Implant Bone Loss: Literature Support
-
ZZZZZZ, 1056-6163, 10.1097/01.id.0000165033.34294.db
-
Misch C.E. Suzuki J.B. Misch-Dietsh F.M. Bidez M.W. A Positive Correlation Between Occlusal Trauma and Peri-Implant Bone Loss: Literature Support. Implant Dent. 2005, 14(2):108-116. ZZZZZZ, 1056-6163, 10.1097/01.id.0000165033.34294.db.
-
(2005)
Implant Dent.
, vol.14
, Issue.2
, pp. 108-116
-
-
Misch, C.E.1
Suzuki, J.B.2
Misch-Dietsh, F.M.3
Bidez, M.W.4
-
28
-
-
6044263659
-
Efficiency Considerations for the Purely Tapered Interference Fit (TIF) Abutments Used in Dental Implants
-
JBENDY, 0148-0731, 10.1115/1.1784473
-
Bozkaya D. Muftu S. Efficiency Considerations for the Purely Tapered Interference Fit (TIF) Abutments Used in Dental Implants. ASME J. Biomech. Eng. 2004, 126(4):393-401. JBENDY, 0148-0731, 10.1115/1.1784473.
-
(2004)
ASME J. Biomech. Eng.
, vol.126
, Issue.4
, pp. 393-401
-
-
Bozkaya, D.1
Muftu, S.2
-
29
-
-
30844452029
-
Survival Estimates and Risk Factors for Failure With 6×5.7-mm Implants
-
ZZZZZZ, 0882-2786
-
Gentile M.A. Chuang S.K. Dodson T.B. Survival Estimates and Risk Factors for Failure With 6×5.7-mm Implants. Int. J. Oral Maxillofac Implants 2005, 20(6):930-937. ZZZZZZ, 0882-2786.
-
(2005)
Int. J. Oral Maxillofac Implants
, vol.20
, Issue.6
, pp. 930-937
-
-
Gentile, M.A.1
Chuang, S.K.2
Dodson, T.B.3
-
30
-
-
16644395903
-
Frailty Approach for the Analysis of Clustered Failure Time Observations in Dental Research
-
JDREAF, 0022-0345, 10.1177/154405910508400109
-
Chuang S.K. Cai T. Douglass C.W. Wei L.J. Dodson T.B. Frailty Approach for the Analysis of Clustered Failure Time Observations in Dental Research. J. Dent. Res. 2005, 84(1):54-58. JDREAF, 0022-0345, 10.1177/154405910508400109.
-
(2005)
J. Dent. Res.
, vol.84
, Issue.1
, pp. 54-58
-
-
Chuang, S.K.1
Cai, T.2
Douglass, C.W.3
Wei, L.J.4
Dodson, T.B.5
-
31
-
-
37249089751
-
Biomechanical Interactions in Tooth-Implant-Supported Fixed Partial Dentures With Variations in the Number of Splinted Teeth and Connector Type: A Finite Element Analysis
-
ZZZZZZ, 0905-7161
-
Chun-Li L. Jen-Chyan W. Wen-Jen C. Biomechanical Interactions in Tooth-Implant-Supported Fixed Partial Dentures With Variations in the Number of Splinted Teeth and Connector Type: A Finite Element Analysis. Clin. Oral Implants Res. 2008, 19(1):107-117. ZZZZZZ, 0905-7161.
-
(2008)
Clin. Oral Implants Res.
, vol.19
, Issue.1
, pp. 107-117
-
-
Chun-Li, L.1
Jen-Chyan, W.2
Wen-Jen, C.3
-
32
-
-
0036550748
-
The Influence of the Location of Load Transfer on Strains Around Implants Supporting Four Unit Cement-Retained Fixed Prostheses: In Vitro Evaluation of Axial Versus Off-Set Loading
-
ZZZZZZ, 0305-182X, 10.1046/j.1365-2842.2002.00867.x
-
Cehreli M.C. Iplikcioglu H. Bilir O.G. The Influence of the Location of Load Transfer on Strains Around Implants Supporting Four Unit Cement-Retained Fixed Prostheses: In Vitro Evaluation of Axial Versus Off-Set Loading. J. Oral Rehabil. 2002, 29(4):394-400. ZZZZZZ, 0305-182X, 10.1046/j.1365-2842.2002.00867.x.
-
(2002)
J. Oral Rehabil.
, vol.29
, Issue.4
, pp. 394-400
-
-
Cehreli, M.C.1
Iplikcioglu, H.2
Bilir, O.G.3
-
33
-
-
1442265885
-
Dental Implant Design and Its Relationship to Long-Term Implant Success
-
ZZZZZZ, 1056-6163, 10.1097/01.ID.0000091140.76130.A1
-
Steigenga J.T. Al-Shammari K.F. Nociti F.H. Misch C.E. Wang H.-L. Dental Implant Design and Its Relationship to Long-Term Implant Success. Implant Dent. 2003, 12(4):306-317. ZZZZZZ, 1056-6163, 10.1097/01.ID.0000091140.76130.A1.
-
(2003)
Implant Dent.
, vol.12
, Issue.4
, pp. 306-317
-
-
Steigenga, J.T.1
Al-Shammari, K.F.2
Nociti, F.H.3
Misch, C.E.4
Wang, H.-L.5
-
34
-
-
0041418181
-
Influence of Implant Design and Bone Quality on Stress/Strain Distribution in Bone Around Implants: A 3-Dimensional Finite Element Analysis
-
ZZZZZZ, 0901-5027
-
Tada S. Stegaroiu R. Kitamura E. Miyakawa O. Kusakari H. Influence of Implant Design and Bone Quality on Stress/Strain Distribution in Bone Around Implants: A 3-Dimensional Finite Element Analysis. Int. J. Oral Maxillofac Surg. 2003, 18(3):357-368. ZZZZZZ, 0901-5027.
-
(2003)
Int. J. Oral Maxillofac Surg.
, vol.18
, Issue.3
, pp. 357-368
-
-
Tada, S.1
Stegaroiu, R.2
Kitamura, E.3
Miyakawa, O.4
Kusakari, H.5
-
35
-
-
0025493944
-
Applicability of Osseointegrated Oral Implants in the Rehabilitation of Partial Edentulism: A Prospective Multicenter Study on 558 Fixtures
-
ZZZZZZ, 0882-2786
-
van Steenberghe D. Lekhlom U. Bolender C. Folmer T. Henry P. Herrmann I. Higuchi K. Laney W. Linden U. Astrand P. Applicability of Osseointegrated Oral Implants in the Rehabilitation of Partial Edentulism: A Prospective Multicenter Study on 558 Fixtures. Int. J. Oral Maxillofac Implants 1990, 5(3):272-281. ZZZZZZ, 0882-2786.
-
(1990)
Int. J. Oral Maxillofac Implants
, vol.5
, Issue.3
, pp. 272-281
-
-
van Steenberghe, D.1
Lekhlom, U.2
Bolender, C.3
Folmer, T.4
Henry, P.5
Herrmann, I.6
Higuchi, K.7
Laney, W.8
Linden, U.9
Astrand, P.10
-
36
-
-
0026084439
-
The Excessive Loss of Branemark Fixtures in Type-IV Bone: A 5-Year Analysis
-
ZZZZZZ, 0022-3492, 10.1902/jop.1991.62.1.2
-
Jaffin R.A. Berman C.L. The Excessive Loss of Branemark Fixtures in Type-IV Bone: A 5-Year Analysis. J. Periodontol. 1991, 62(1):2-4. ZZZZZZ, 0022-3492, 10.1902/jop.1991.62.1.2.
-
(1991)
J. Periodontol.
, vol.62
, Issue.1
, pp. 2-4
-
-
Jaffin, R.A.1
Berman, C.L.2
-
37
-
-
0034570059
-
Implant-Abutment Interface: Biomechanical Study of Flat Top Versus Conical
-
10.1111/j.1708-8208.2000.tb00104.x
-
Hansson S. Implant-Abutment Interface: Biomechanical Study of Flat Top Versus Conical. Clinical Implant Dentistry and Related Research 2000, 2(1):33-41. 10.1111/j.1708-8208.2000.tb00104.x.
-
(2000)
Clinical Implant Dentistry and Related Research
, vol.2
, Issue.1
, pp. 33-41
-
-
Hansson, S.1
|