2
-
-
0026585652
-
Monte Carlo calculations of electron beam parameters for three Philips linear accelerators
-
Udale-Smith Mary Monte Carlo calculations of electron beam parameters for three Philips linear accelerators. Phys Med Biol 1992, 37(1):85-105.
-
(1992)
Phys Med Biol
, vol.37
, Issue.1
, pp. 85-105
-
-
Udale-Smith, M.1
-
3
-
-
51349159285
-
60Co brachytherapy sources: results of measurements on a GZP6 brachytherapy afterloading unit
-
60Co brachytherapy sources: results of measurements on a GZP6 brachytherapy afterloading unit. Rep Pract Oncol Radiother 2008, 13(2):69-73.
-
(2008)
Rep Pract Oncol Radiother
, vol.13
, Issue.2
, pp. 69-73
-
-
Mesbahi, A.1
Naseri, A.2
-
4
-
-
76349097196
-
60Co sources: treatment planning system versus Monte Carlo calculations
-
60Co sources: treatment planning system versus Monte Carlo calculations. Iran J Radiat Res 2008, 5(4):181-186.
-
(2008)
Iran J Radiat Res
, vol.5
, Issue.4
, pp. 181-186
-
-
Mesbahi, A.1
-
5
-
-
0033981978
-
Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model
-
Karaiskos P., Angelopoulos A., Baras P., Rozaki-Mavrouli H., Sandilos P., Vlachos L., et al. Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model. Phys Med Biol 2000 Feb, 45(2):383-398.
-
(2000)
Phys Med Biol
, vol.45
, Issue.2
, pp. 383-398
-
-
Karaiskos, P.1
Angelopoulos, A.2
Baras, P.3
Rozaki-Mavrouli, H.4
Sandilos, P.5
Vlachos, L.6
-
6
-
-
27944477251
-
Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator
-
Gifford K.A., Mourtada F., Cho S.H., Lawyer A., Horton J.L. Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator. Radiother Oncol 2005 Nov, 77(2):210-215.
-
(2005)
Radiother Oncol
, vol.77
, Issue.2
, pp. 210-215
-
-
Gifford, K.A.1
Mourtada, F.2
Cho, S.H.3
Lawyer, A.4
Horton, J.L.5
-
7
-
-
0037391563
-
60Co HDR brachytherapy sources
-
60Co HDR brachytherapy sources. Med Phys 2003 Apr, 30(4):712-721.
-
(2003)
Med Phys
, vol.30
, Issue.4
, pp. 712-721
-
-
Papagiannis, P.1
Angelopoulos, A.2
Pantelis, E.3
Sakelliou, L.4
Karaiskos, P.5
Shimizu, Y.6
-
8
-
-
77951645287
-
Monte Carlo and experimental relative dose determination for an Ir-192 source in water phantom
-
Mowlavi A.A., Cupardo F., Severgnini M. Monte Carlo and experimental relative dose determination for an Ir-192 source in water phantom. Iran J Radiat Res 2008, 6(1):37-42.
-
(2008)
Iran J Radiat Res
, vol.6
, Issue.1
, pp. 37-42
-
-
Mowlavi, A.A.1
Cupardo, F.2
Severgnini, M.3
-
9
-
-
0031832848
-
Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192 Ir remote afterloading
-
Watanabe Y, Roy J., Harrington P.J., Anderson L.L. Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192 Ir remote afterloading. Med Phys 1998 May 5, 25(5):736-745.
-
(1998)
Med Phys
, vol.25
, Issue.5
, pp. 736-745
-
-
Watanabe, Y.1
Roy, J.2
Harrington, P.J.3
Anderson, L.L.4
-
10
-
-
0035704227
-
Dosimetry of source stepping for intravascular brachytherapy
-
Li X.A., Suntharalingam M., Yu C. Dosimetry of source stepping for intravascular brachytherapy. Cardiovasc Radiat Med 2001 Jul, 2(3):165-172.
-
(2001)
Cardiovasc Radiat Med
, vol.2
, Issue.3
, pp. 165-172
-
-
Li, X.A.1
Suntharalingam, M.2
Yu, C.3
-
11
-
-
0036918330
-
Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy
-
Miften M.M., Das S.K., Shafman T.D., Marks L.B. Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy. Med Phys 2002 Dec, 29(12):2891-2896.
-
(2002)
Med Phys
, vol.29
, Issue.12
, pp. 2891-2896
-
-
Miften, M.M.1
Das, S.K.2
Shafman, T.D.3
Marks, L.B.4
-
12
-
-
0032909966
-
Dose errors in the near field of an HDR brachytherapy stepping source
-
Wong T., Wallace S., Fernando W., Schumer W., Quong G. Dose errors in the near field of an HDR brachytherapy stepping source. Phys Med Biol 1999 Feb, 44(2):357-363.
-
(1999)
Phys Med Biol
, vol.44
, Issue.2
, pp. 357-363
-
-
Wong, T.1
Wallace, S.2
Fernando, W.3
Schumer, W.4
Quong, G.5
-
13
-
-
0035126054
-
Transit dose of an Ir-192 HDR brachytherapy stepping source
-
Wong T., Fernando W., Johnston P.N., Bubb I.F. Transit dose of an Ir-192 HDR brachytherapy stepping source. Phys Med Biol 2001, 46:323-331.
-
(2001)
Phys Med Biol
, vol.46
, pp. 323-331
-
-
Wong, T.1
Fernando, W.2
Johnston, P.N.3
Bubb, I.F.4
-
14
-
-
0029038383
-
Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192 Ir sources
-
Monte
-
Williamson J.F., Li Z., Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192 Ir sources. Med Phys 1995 Jun, 22(6):809-819.
-
(1995)
Med Phys
, vol.22
, Issue.6
, pp. 809-819
-
-
Williamson, J.F.1
Li, Z.2
-
15
-
-
79551571817
-
-
Waters LS. MCNPX User's manual, version 2.4.0. Report LA-CP-02-408. Los Alamos National Laboratory;
-
Waters LS. MCNPX User's manual, version 2.4.0. Report LA-CP-02-408. Los Alamos National Laboratory; 2002.
-
(2002)
-
-
|