메뉴 건너뛰기




Volumn 45, Issue 2, 2000, Pages 383-398

Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model

Author keywords

[No Author keywords available]

Indexed keywords

IRIDIUM 192;

EID: 0033981978     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/2/309     Document Type: Article
Times cited : (25)

References (32)
  • 1
    • 0003618204 scopus 로고
    • Specification of brachytherapy source strength
    • New York: American Institute of Physics
    • AAPM (American Association of Physicists in Medicine) 1987 Specification of brachytherapy source strength AAPM Report 21 (New York: American Institute of Physics)
    • (1987) AAPM Report 21
  • 2
    • 0003485878 scopus 로고
    • Remote afterloading technology
    • New York: American Institute of Physics
    • _1993 Remote afterloading technology AAPM Report 41 (New York: American Institute of Physics)
    • (1993) AAPM Report 41
  • 3
    • 0025904558 scopus 로고
    • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy
    • Angelopoulos A, Perris A, Sakellariou K, Sakelliou L, Sarigiannis K and Zarris G 1991 Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy Phys. Med. Biol. 36 763-78
    • (1991) Phys. Med. Biol. , vol.36 , pp. 763-778
    • Angelopoulos, A.1    Perris, A.2    Sakellariou, K.3    Sakelliou, L.4    Sarigiannis, K.5    Zarris, G.6
  • 6
    • 0021906794 scopus 로고
    • Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies
    • Chan H-P and Doi K 1985 Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies Med. Phys. 12 152-65
    • (1985) Med. Phys. , vol.12 , pp. 152-165
    • Chan, H.-P.1    Doi, K.2
  • 8
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • Daskalov G M, Löffler E and Williamson J F 1998 Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source Med. Phys. 25 2200-8
    • (1998) Med. Phys. , vol.25 , pp. 2200-2208
    • Daskalov, G.M.1    Löffler, E.2    Williamson, J.F.3
  • 9
    • 0023716352 scopus 로고
    • Comparison of measured and calculated dose distribution around an iridium-192 wire
    • Gillin M T, Lopez F, Kline R W, Grimm D F and Niroomand-Rad A 1988 Comparison of measured and calculated dose distribution around an iridium-192 wire Med. Phys. 15 915-18
    • (1988) Med. Phys. , vol.15 , pp. 915-918
    • Gillin, M.T.1    Lopez, F.2    Kline, R.W.3    Grimm, D.F.4    Niroomand-Rad, A.5
  • 11
    • 2742546324 scopus 로고
    • Relativistic atomic form factors and photon coherent scattering cross sections
    • Hubbel J H and Overbo I 1979 Relativistic atomic form factors and photon coherent scattering cross sections J. Phys. Chem. Ref. Data 8 69-105
    • (1979) J. Phys. Chem. Ref. Data , vol.8 , pp. 69-105
    • Hubbel, J.H.1    Overbo, I.2
  • 12
    • 0001351569 scopus 로고
    • Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest
    • Gaithersburg, MD: NIST
    • Hubbel J H and Seltzer S M 1995 Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest NISTIR 5632 (Gaithersburg, MD: NIST)
    • (1995) NISTIR 5632
    • Hubbel, J.H.1    Seltzer, S.M.2
  • 14
    • 0004163979 scopus 로고
    • Dose and volume specification for reporting intracavitary therapy in gynaecology
    • Bethesda, MD: ICRU
    • ICRU (International Commission on Radiation Units and Measurements) 1985 Dose and volume specification for reporting intracavitary therapy in gynaecology ICRU Report 38 (Bethesda, MD: ICRU)
    • (1985) ICRU Report 38
  • 17
    • 0033957810 scopus 로고    scopus 로고
    • Limitations of the point and line source approximations for the determination of geometry factors around brachytherapy sources
    • abstract available
    • Karaiskos P, Sakelliou L and Sandilos P 2000 Limitations of the point and line source approximations for the determination of geometry factors around brachytherapy sources Med. Phys. 27 (abstract available)
    • (2000) Med. Phys. , vol.27
    • Karaiskos, P.1    Sakelliou, L.2    Sandilos, P.3
  • 19
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group 43
    • Nath R, Anderson L, Luxton G, Weaver K, Williamson J F and Meigooni A S 1995 Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group 43 Med. Phys. 22 209-34
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.2    Luxton, G.3    Weaver, K.4    Williamson, J.F.5    Meigooni, A.S.6
  • 21
    • 0025018350 scopus 로고
    • 241am vaginal applicators including the source-to-source shielding effects
    • 241Am vaginal applicators including the source-to-source shielding effects Med. Phys. 17 833-42
    • (1990) Med. Phys. , vol.17 , pp. 833-842
    • Nath, R.1    Park, C.H.2    King, C.R.3    Muench, P.4
  • 22
    • 0029895014 scopus 로고    scopus 로고
    • 192Ir source using a primary and scatter dose separation technique
    • 192Ir source using a primary and scatter dose separation technique Phys. Med. Biol. 41 1007-24
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1007-1024
    • Russel, K.R.1    Ahnesjo, A.2
  • 24
    • 3042914196 scopus 로고
    • X-ray attenuation cross sections for energies 100 eV to 100 keV and elements Z = 1 to Z = 92
    • Saloman E B, Hubbel J H and Scofield J H 1988 X-ray attenuation cross sections for energies 100 eV to 100 keV and elements Z = 1 to Z = 92 At. Data Nucl. Data Tables 38 1-197
    • (1988) At. Data Nucl. Data Tables , vol.38 , pp. 1-197
    • Saloman, E.B.1    Hubbel, J.H.2    Scofield, J.H.3
  • 28
    • 0025334388 scopus 로고
    • Dose calculations about shielded gynaecological colpostats
    • _1990 Dose calculations about shielded gynaecological colpostats Int. J. Radiat. Oncol. Biol. Phys. 19 167-78
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.19 , pp. 167-178
  • 29
    • 0030443804 scopus 로고    scopus 로고
    • 192Ir brachytherapy sources
    • 192Ir brachytherapy sources Int. J. Radiat. Oncol. Biol. Phys. 36 1239-50
    • Int. J. Radiat. Oncol. Biol. Phys. , vol.36 , pp. 1239-1250
  • 32
    • 0020592244 scopus 로고
    • Monte Carlo evaluation of the Sievert integral for brachytherapy dosimetry
    • Williamson J F, Morin R M and Khan F M 1983 Monte Carlo evaluation of the Sievert integral for brachytherapy dosimetry Phys. Med. Biol. 28 1021-32
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1021-1032
    • Williamson, J.F.1    Morin, R.M.2    Khan, F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.