메뉴 건너뛰기




Volumn 13, Issue 2, 2008, Pages 69-73

In-air calibration of new high dose rate 60Co brachytherapy sources: Results of measurements on a GZP6 brachytherapy afterloading unit

Author keywords

[No Author keywords available]

Indexed keywords

COBALT 60;

EID: 51349159285     PISSN: 15071367     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1507-1367(10)60084-3     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 0021967353 scopus 로고
    • Physical characteristics of the Selectron high dose rate intracavitary afterloader
    • Chenery SG, Pla M, and Podgorsak EB: Physical characteristics of the Selectron high dose rate intracavitary afterloader, Br. J. Radiol. 1985: 58 (692) 735-740.
    • (1985) Br. J. Radiol , vol.58 , Issue.692 , pp. 735-740
    • Chenery, S.G.1    Pla, M.2    Podgorsak, E.B.3
  • 2
    • 0025733704 scopus 로고
    • Calibration of a Microselectron HDR iridium 192 source
    • Flynn A, and Workman G: Calibration of a Microselectron HDR iridium 192 source, Br. J. Radiol. 1991: 64 (764) 734-739.
    • (1991) Br. J. Radiol , vol.64 , Issue.764 , pp. 734-739
    • Flynn, A.1    Workman, G.2
  • 4
    • 0028230872 scopus 로고    scopus 로고
    • Kutcher GJ, Coia L, Gillin M, et al: Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40, Med. Phys.1988: 21 (4) 581-618.
    • Kutcher GJ, Coia L, Gillin M, et al: Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40, Med. Phys.1988: 21 (4) 581-618.
  • 6
    • 0034004556 scopus 로고    scopus 로고
    • Measurement of dose-rate constant for 103Pd seeds with air kerma strength calibration based upon a primary national standard
    • Nath R, Yue N, Shahnazi K, and Bongiorni PJ: Measurement of dose-rate constant for 103Pd seeds with air kerma strength calibration based upon a primary national standard, Med. Phys. 2000: 27 (4) 655-658.
    • (2000) Med. Phys , vol.27 , Issue.4 , pp. 655-658
    • Nath, R.1    Yue, N.2    Shahnazi, K.3    Bongiorni, P.J.4
  • 8
    • 0028274912 scopus 로고
    • Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source
    • Perera H, Williamson JF, Li Z, Mishra V, and Meigooni AS: Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source, Int. J. Radiat. Oncol. Biol. Phys. 1994: 28 (4) 953-970.
    • (1994) Int. J. Radiat. Oncol. Biol. Phys , vol.28 , Issue.4 , pp. 953-970
    • Perera, H.1    Williamson, J.F.2    Li, Z.3    Mishra, V.4    Meigooni, A.S.5
  • 9
    • 0038510175 scopus 로고    scopus 로고
    • Monte Carlo aided room scatter corrections in the air-kerma strength standardization of 169Yb and 60Co brachytherapy sources
    • Selvam TP, Rajan KN, Sethulakshmi P, and Bhatt BC: Monte Carlo aided room scatter corrections in the air-kerma strength standardization of 169Yb and 60Co brachytherapy sources, Phys. Med. Biol. 2003: 48(11) N139-N147.
    • (2003) Phys. Med. Biol , vol.48 , Issue.11
    • Selvam, T.P.1    Rajan, K.N.2    Sethulakshmi, P.3    Bhatt, B.C.4
  • 11
    • 0001882717 scopus 로고
    • Effect of finite size of ionization chambers on measurement of small photon sources
    • Kondo S and Randolph ML: Effect of finite size of ionization chambers on measurement of small photon sources, Rad. Res. 1960: 13: 37-60.
    • (1960) Rad. Res , vol.13 , pp. 37-60
    • Kondo, S.1    Randolph, M.L.2
  • 12
    • 0025271124 scopus 로고
    • Correction factors for thick-walled ionization chambers in pointsource photon beams
    • Bielajew AF: Correction factors for thick-walled ionization chambers in pointsource photon beams, Phys. Med. Biol. 1990; 35: 501-516.
    • (1990) Phys. Med. Biol , vol.35 , pp. 501-516
    • Bielajew, A.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.