메뉴 건너뛰기




Volumn 28, Issue 10, 2010, Pages 714-719

Hepatic computed tomography perfusion: Comparison of maximum slope and dual-input single-compartment methods

Author keywords

Compartment model; Contrast enhancement; CT perfusion; Liver; Maximum slope method

Indexed keywords

CONTRAST MEDIUM;

EID: 79251534712     PISSN: 18671071     EISSN: 1867108X     Source Type: Journal    
DOI: 10.1007/s11604-010-0497-y     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 13844272509 scopus 로고    scopus 로고
    • Perfusion imaging of the liver: Current challenges and future goals
    • DOI 10.1148/radiol.2343031362
    • P.V. Pandharipande G.A. Krinsky 2005 Perfusion imaging of the liver: current challenges and future goals Radiology 234 661 673 10.1148/radiol. 2343031362 15734925 (Pubitemid 40250807)
    • (2005) Radiology , vol.234 , Issue.3 , pp. 661-673
    • Pandharipande, P.V.1    Krinsky, G.A.2    Rusinek, H.3    Lee, V.S.4
  • 3
    • 37249018732 scopus 로고    scopus 로고
    • Assessment of the severity of liver disease and fibrotic change: The usefulness of hepatic CT perfusion imaging
    • 16969479
    • K. Hashimoto T. Murakami K. Dono M. Hori T. Kim M. Kudo 2006 Assessment of the severity of liver disease and fibrotic change: the usefulness of hepatic CT perfusion imaging Oncol Rep 16 677 683 16969479
    • (2006) Oncol Rep , vol.16 , pp. 677-683
    • Hashimoto, K.1    Murakami, T.2    Dono, K.3    Hori, M.4    Kim, T.5    Kudo, M.6
  • 4
    • 6344261954 scopus 로고    scopus 로고
    • Quantitative measurement of hepatic portal perfusion by multidetector row CT with compensation for respiratory misregistration
    • DOI 10.1259/bjr/41168942
    • A. Nakashige J. Horiguchi A. Tamura T. Asahara F. Shimamoto K. Ito 2004 Quantitative measurement of hepatic portal perfusion by multidetector row CT with compensation for respiratory misregistration Br J Radiol 77 728 734 1:STN:280:DC%2BD2crktlaktQ%3D%3D 10.1259/bjr/41168942 15447957 (Pubitemid 39386919)
    • (2004) British Journal of Radiology , vol.77 , Issue.921 , pp. 728-734
    • Nakashige, A.1    Horiguchi, J.2    Tamura, A.3    Asahara, T.4    Shimamoto, F.5    Ito, K.6
  • 5
    • 73449107726 scopus 로고    scopus 로고
    • Perfusion CT in cirrhotic patients with early stage hepatocellular carcinoma: Assessment of tumor-related vascularization
    • 10.1016/j.ejrad.2008.10.014 19054640
    • D. Ippolito S. Sironi M. Pozzi L. Antolini F. Invernizzi L. Ratti, et al. 2010 Perfusion CT in cirrhotic patients with early stage hepatocellular carcinoma: assessment of tumor-related vascularization Eur J Radiol 73 148 152 10.1016/j.ejrad.2008.10.014 19054640
    • (2010) Eur J Radiol , vol.73 , pp. 148-152
    • Ippolito, D.1    Sironi, S.2    Pozzi, M.3    Antolini, L.4    Invernizzi, F.5    Ratti, L.6
  • 6
    • 77952091825 scopus 로고    scopus 로고
    • Perfusion computed tomography evaluation of angiogenesis in liver cancer
    • 10.1007/s00330-009-1693-y 20179942
    • H.F. Yang Y. Du J.X. Ni X.P. Zhou J.D. Li Q. Zhang, et al. 2010 Perfusion computed tomography evaluation of angiogenesis in liver cancer Eur Radiol 20 1424 1430 10.1007/s00330-009-1693-y 20179942
    • (2010) Eur Radiol , vol.20 , pp. 1424-1430
    • Yang, H.F.1    Du, Y.2    Ni, J.X.3    Zhou, X.P.4    Li, J.D.5    Zhang, Q.6
  • 7
    • 79953775815 scopus 로고    scopus 로고
    • Perfusion patterns of metastatic gastrointestinal stromal tumor lesions under specific molecular therapy
    • Aug 29 [Epub ahead of print]. doi:10.1016/j.ejrad.2009.07.031
    • Schlemmer M, Sourbron SP, Schinwald N, Nikolaou K, Becker CR, Reiser MF, et al. Perfusion patterns of metastatic gastrointestinal stromal tumor lesions under specific molecular therapy. Eur J Radiol 2009 Aug 29 [Epub ahead of print]. doi:10.1016/j.ejrad.2009.07.031
    • (2009) Eur J Radiol
    • Schlemmer, M.1    Sourbron, S.P.2    Schinwald, N.3    Nikolaou, K.4    Becker, C.R.5    Reiser, M.F.6
  • 8
    • 67649083526 scopus 로고    scopus 로고
    • Liver perfusion with dynamic multidetector-row computed tomography as an objective method to evaluate the efficacy of chemotherapy in patients with colorectal cancer
    • 10.1016/j.clinimag.2008.10.030 19559351
    • S. Pauls A. Gabelmann W. Heinz E. Fröhlich M.S. Juchems H.J. Brambs, et al. 2009 Liver perfusion with dynamic multidetector-row computed tomography as an objective method to evaluate the efficacy of chemotherapy in patients with colorectal cancer Clin Imaging 33 289 294 10.1016/j.clinimag.2008.10.030 19559351
    • (2009) Clin Imaging , vol.33 , pp. 289-294
    • Pauls, S.1    Gabelmann, A.2    Heinz, W.3    Fröhlich, E.4    Juchems, M.S.5    Brambs, H.J.6
  • 9
    • 78651255269 scopus 로고    scopus 로고
    • Hemodynamic alterations in anterior segment of liver graft after right-lobe living-donor liver transplantation: Computed tomography perfusion imaging findings
    • Aug 11 [Epub ahead of print]. doi: 10.1007/s00261-009-9563-2
    • Qian LJ, Zhuang ZG, Cheng YF, Xia Q, Zhang JJ, Xu JR. Hemodynamic alterations in anterior segment of liver graft after right-lobe living-donor liver transplantation: computed tomography perfusion imaging findings. Abdom Imaging 2000 Aug 11 [Epub ahead of print]. doi: 10.1007/s00261-009-9563-2
    • (2000) Abdom Imaging
    • Qian, L.J.1    Zhuang, Z.G.2    Cheng, Y.F.3    Xia, Q.4    Zhang, J.J.5    Xu, J.R.6
  • 10
    • 70350173425 scopus 로고    scopus 로고
    • Computed tomography perfusion in living donor liver transplantation: An initial study of normal hemodynamic changes in liver grafts
    • 10.1111/j.1399-0012.2009.00991.x 19473203
    • Z.G. Zhuang L.J. Qian B.X. Wang Y. Zhou Q.G. Li J.R. Xu, et al. 2009 Computed tomography perfusion in living donor liver transplantation: an initial study of normal hemodynamic changes in liver grafts Clin Transplant 23 692 699 10.1111/j.1399-0012.2009.00991.x 19473203
    • (2009) Clin Transplant , vol.23 , pp. 692-699
    • Zhuang, Z.G.1    Qian, L.J.2    Wang, B.X.3    Zhou, Y.4    Li, Q.G.5    Xu, J.R.6
  • 12
    • 69449095265 scopus 로고    scopus 로고
    • Early detection of local RFA site recurrence using total liver volume perfusion CT initial experience
    • 10.1016/j.acra.2009.03.023 19524457
    • M.R. Meijerink J.H. van Waesberghe L. van der Weide P. van den Tol S. Meijer E.F. Comans, et al. 2009 Early detection of local RFA site recurrence using total liver volume perfusion CT initial experience Acad Radiol 16 1215 1222 10.1016/j.acra.2009.03.023 19524457
    • (2009) Acad Radiol , vol.16 , pp. 1215-1222
    • Meijerink, M.R.1    Van Waesberghe, J.H.2    Van Der Weide, L.3    Van Den Tol, P.4    Meijer, S.5    Comans, E.F.6
  • 13
    • 0035144643 scopus 로고    scopus 로고
    • Early changes in liver perfusion caused by occult metastases in rats: Detection with quantitative CT
    • 1:STN:280:DC%2BD3M3lvVehsg%3D%3D 11161178
    • C. Cuenod I. Leconte N. Siauve A. Resten C. Dromain B. Poulet, et al. 2001 Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT Radiology 218 556 561 1:STN:280: DC%2BD3M3lvVehsg%3D%3D 11161178
    • (2001) Radiology , vol.218 , pp. 556-561
    • Cuenod, C.1    Leconte, I.2    Siauve, N.3    Resten, A.4    Dromain, C.5    Poulet, B.6
  • 15
    • 0027226363 scopus 로고
    • Functional images of hepatic perfusion obtained with dynamic CT
    • 1:STN:280:DyaK3szhslyksg%3D%3D 8327686
    • K.A. Miles M.P. Hayball A.K. Dixon 1993 Functional images of hepatic perfusion obtained with dynamic CT Radiology 188 405 411 1:STN:280: DyaK3szhslyksg%3D%3D 8327686
    • (1993) Radiology , vol.188 , pp. 405-411
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 16
    • 0034544721 scopus 로고    scopus 로고
    • Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model
    • DOI 10.1042/CS20000080
    • R. Materne B.E. Van Beers A.M. Smith I. Leconte J. Jamart J.P. Dehoux, et al. 2000 Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model Clin Sci (Lond) 99 517 525 1:STN:280:DC%2BD3M7ksFGrsw%3D%3D 10.1042/CS20000080 (Pubitemid 32014558)
    • (2000) Clinical Science , vol.99 , Issue.6 , pp. 517-525
    • Materne, R.1    Van Beers, B.E.2    Smith, A.M.3    Leconte, I.4    Jamart, J.5    Dehoux, J.-P.6    Keyeux, A.7    Horsmans, Y.8
  • 17
    • 53749098967 scopus 로고    scopus 로고
    • A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model
    • 1:STN:280:DC%2BD1cngslWitQ%3D%3D 10.1259/bjr/52166324 18591199
    • S. Miyazaki K. Murase T. Yoshikawa S. Morimoto Y. Ohno K. Sugimura 2008 A quantitative method for estimating hepatic blood flow using a dual-input single-compartment model Br J Radiol 81 790 800 1:STN:280:DC%2BD1cngslWitQ%3D%3D 10.1259/bjr/52166324 18591199
    • (2008) Br J Radiol , vol.81 , pp. 790-800
    • Miyazaki, S.1    Murase, K.2    Yoshikawa, T.3    Morimoto, S.4    Ohno, Y.5    Sugimura, K.6
  • 18
    • 65149105797 scopus 로고    scopus 로고
    • Quantification of hepatic arterial and portal perfusion with dynamic computed tomography: Comparison of maximum-slope and dual-input one-compartment model methods
    • 10.1007/s11604-008-0312-1 19412682
    • M. Miyazaki Y. Tsushima A. Miyazaki B. Paudyal M. Amanuma K. Endo 2009 Quantification of hepatic arterial and portal perfusion with dynamic computed tomography: comparison of maximum-slope and dual-input one-compartment model methods Jpn J Radiol 27 143 150 10.1007/s11604-008-0312-1 19412682
    • (2009) Jpn J Radiol , vol.27 , pp. 143-150
    • Miyazaki, M.1    Tsushima, Y.2    Miyazaki, A.3    Paudyal, B.4    Amanuma, M.5    Endo, K.6
  • 19
    • 0031813548 scopus 로고    scopus 로고
    • Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model
    • 1:STN:280:DyaK1c3nt1yjtQ%3D%3D 9609887
    • K.T. Bae J.P. Heiken J.A. Brink 1998 Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model Radiology 207 657 662 1:STN:280:DyaK1c3nt1yjtQ%3D%3D 9609887
    • (1998) Radiology , vol.207 , pp. 657-662
    • Bae, K.T.1    Heiken, J.P.2    Brink, J.A.3
  • 20
    • 2442648019 scopus 로고    scopus 로고
    • Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients
    • 15140710
    • M. Wintermark W.S. Smith N.U. Ko M. Quist P. Schnyder W.P. Dillon 2004 Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients AJNR Am J Neuroradiol 25 720 729 15140710
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 720-729
    • Wintermark, M.1    Smith, W.S.2    Ko, N.U.3    Quist, M.4    Schnyder, P.5    Dillon, W.P.6
  • 21
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • 11222202
    • B.E. Van Beers I. Leconte R. Materne A.M. Smith J. Jamart Y. Horsmans 2001 Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity AJR Am J Roentgenol 176 667 673 11222202
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3    Smith, A.M.4    Jamart, J.5    Horsmans, Y.6
  • 22
    • 52049083672 scopus 로고    scopus 로고
    • Total-liver-volume perfusion CT using 3-D image fusion to improve detection and characterization of liver metastases
    • 10.1007/s00330-008-0996-8 18491094
    • M.R. Meijerink J.H. van Waesberghe L. van der Weide P. van den Tol S. Meijer C. van Kuijk 2008 Total-liver-volume perfusion CT using 3-D image fusion to improve detection and characterization of liver metastases Eur Radiol 18 2345 2354 10.1007/s00330-008-0996-8 18491094
    • (2008) Eur Radiol , vol.18 , pp. 2345-2354
    • Meijerink, M.R.1    Van Waesberghe, J.H.2    Van Der Weide, L.3    Van Den Tol, P.4    Meijer, S.5    Van Kuijk, C.6
  • 23
    • 70350166688 scopus 로고    scopus 로고
    • Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: Acquisition technique, post-processing and initial results
    • 10.1007/s00330-009-1453-z 19471941
    • S. Kandel C. Kloeters H. Meyer P. Hein A. Hilbig P. Rogalla 2009 Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results Eur Radiol 19 2641 2646 10.1007/s00330-009-1453-z 19471941
    • (2009) Eur Radiol , vol.19 , pp. 2641-2646
    • Kandel, S.1    Kloeters, C.2    Meyer, H.3    Hein, P.4    Hilbig, A.5    Rogalla, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.