메뉴 건너뛰기




Volumn 13, Issue 2, 2011, Pages 237-243

Acute haemodynamic effects of increase in paced heart rate in heart failure patients recorded with an implantable haemodynamic monitor

Author keywords

Cardiac resynchronization therapy; Haemodynamic; Heart failure; Heart rate

Indexed keywords

AGED; ARTERIAL PRESSURE; ARTICLE; BICYCLE ERGOMETRY; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOMYOPATHY; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CORRELATION ANALYSIS; DIASTOLIC BLOOD PRESSURE; DISEASE SEVERITY; HEART BEAT; HEART FAILURE; HEART HEMODYNAMICS; HEART LEFT VENTRICLE FILLING PRESSURE; HEART OUTPUT; HEART RATE; HEART RIGHT VENTRICLE; HEART RIGHT VENTRICLE PRESSURE; HEMODYNAMIC MONITORING; HUMAN; IMPLANT; IMPLANTABLE HEMODYNAMIC MONITOR; MALE; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE; VASCULAR RESISTANCE;

EID: 79251499313     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/euq354     Document Type: Article
Times cited : (14)

References (31)
  • 1
    • 53549085406 scopus 로고    scopus 로고
    • ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: The task force for the diagnosis and treatment of acute and chronic heart failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM)
    • Dickstein K, Cohen-Solal A, Filippatos G, McMurray JJ, Ponikowski P, Poole-Wilson PA et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: the task force for the diagnosis and treatment of acute and chronic heart failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM). Eur J Heart Fail 2008;10:933-89.
    • (2008) Eur J Heart Fail , vol.10 , pp. 933-89
    • Dickstein, K.1    Cohen-Solal, A.2    Filippatos, G.3    McMurray, J.J.4    Ponikowski, P.5    Poole-Wilson, P.A.6
  • 2
    • 0000515140 scopus 로고
    • Uber die Eigenthumlichkeiten der Reizbarkeit welche die Muskel-fasern des Herzens zeigen
    • Bowditch HP. Uber die Eigenthumlichkeiten der Reizbarkeit, welche die Muskel-fasern des Herzens zeigen. Ber Sachs Ges (Akad) Wiss 1871;23:652-89.
    • (1871) Ber Sachs Ges (Akad) Wiss , vol.23 , pp. 652-89
    • Bowditch, H.P.1
  • 4
    • 0024261139 scopus 로고
    • Depression of systolic and diastolic myocardial reserve during atrial pacing tachy-cardia in patients with dilated cardiomyopathy
    • Feldman MD, Alderman JD, Aroesty JM, Royal HD, Ferguson JJ, Owen RM et al. Depression of systolic and diastolic myocardial reserve during atrial pacing tachy-cardia in patients with dilated cardiomyopathy. J Clin Invest 1988;82:1661-9.
    • (1988) J Clin Invest , vol.82 , pp. 1661-9
    • Feldman, M.D.1    Alderman, J.D.2    Aroesty, J.M.3    Royal, H.D.4    Ferguson, J.J.5    Owen, R.M.6
  • 5
    • 0028322990 scopus 로고
    • Influ-ence of the force-frequency relationship on haemodynamics and left ventricular function in patients with non-failing hearts and in patients with dilated cardiomyo-pathy
    • Hasenfuss G, Holubarsch C, Hermann HP, Astheimer K, Pieske B, Just H. Influ-ence of the force-frequency relationship on haemodynamics and left ventricular function in patients with non-failing hearts and in patients with dilated cardiomyo-pathy. Eur Heart J 1994;15:164-70.
    • (1994) Eur Heart J , vol.15 , pp. 164-70
    • Hasenfuss, G.1    Holubarsch, C.2    Hermann, H.P.3    Astheimer, K.4    Pieske, B.5    Just, H.6
  • 6
    • 33645064576 scopus 로고    scopus 로고
    • Biventricu-lar pacing improves the blunted force-frequency relation present during univen-tricular pacing in patients with heart failure and conduction delay
    • Vollmann D, Luthje L, Schott P, Hasenfuss G, Unterberg-Buchwald C. Biventricu-lar pacing improves the blunted force-frequency relation present during univen-tricular pacing in patients with heart failure and conduction delay. Circulation 2006;113:953-9.
    • (2006) Circulation , vol.113 , pp. 953-9
    • Vollmann, D.1    Luthje, L.2    Schott, P.3    Hasenfuss, G.4    Unterberg-Buchwald, C.5
  • 7
    • 33645748715 scopus 로고    scopus 로고
    • Hemodynamic effects of long-term cardiac resynchronization therapy: Analysis by pressure-volume loops
    • Steendijk P, Tulner SA, Bax JJ, Oemrawsingh PV, Bleeker GB, van Erven L et al. Hemodynamic effects of long-term cardiac resynchronization therapy: analysis by pressure-volume loops. Circulation 2006;113:1295-304.
    • (2006) Circulation , vol.113 , pp. 1295-304
    • Steendijk, P.1    Tulner, S.A.2    Bax, J.J.3    Oemrawsingh, P.V.4    Bleeker, G.B.5    Van Erven, L.6
  • 8
    • 41949095322 scopus 로고    scopus 로고
    • Rate response and cardiac resynchronisation therapy in chronic heart failure: Higher cardiac output does not acutely improve exercise performance: A pilot trial
    • Van Thielen G, Paelinck BP, Beckers P, Vrints CJ, Conraads VM. Rate response and cardiac resynchronisation therapy in chronic heart failure: higher cardiac output does not acutely improve exercise performance: a pilot trial. Eur J Cardi-ovasc Prev Rehabil 2008;15:197-202.
    • (2008) Eur J Cardi-ovasc Prev Rehabil , vol.15 , pp. 197-202
    • Van Thielen, G.1    Paelinck, B.P.2    Beckers, P.3    Vrints, C.J.4    Conraads, V.M.5
  • 10
    • 0033108072 scopus 로고    scopus 로고
    • Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endo-cardial acceleration measurements
    • Ritter P, Padeletti L, Gillio-Meina L, Gaggini G. Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endo-cardial acceleration measurements. Europace 1999;1:126-30.
    • (1999) Europace , vol.1 , pp. 126-30
    • Ritter, P.1    Padeletti, L.2    Gillio-Meina, L.3    Gaggini, G.4
  • 11
    • 0029257708 scopus 로고
    • Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transdu-cer
    • Ohlsson A, Bennett T, Nordlander R, Ryden J, Astrom H, Ryden L. Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transdu-cer. J Card Fail 1995;1:161-8.
    • (1995) J Card Fail , vol.1 , pp. 161-8
    • Ohlsson, A.1    Bennett, T.2    Nordlander, R.3    Ryden, J.4    Astrom, H.5    Ryden, L.6
  • 12
    • 0028929801 scopus 로고
    • Measurement of pulmonary arterydiastolic pressure from the rightventricle
    • Reynolds DW, Bartelt N, Taepke R, Bennett TD. Measurement of pulmonary arterydiastolic pressure from the rightventricle.JAm Coll Cardiol1995;25:1176- 82.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1176-82
    • Reynolds, D.W.1    Bartelt, N.2    Taepke, R.3    Bennett, T.D.4
  • 13
    • 0036097960 scopus 로고    scopus 로고
    • Con-tinuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure
    • Magalski A, Adamson P, Gadler F, Boehm M, Steinhaus D, Reynolds D et al. Con-tinuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter, 12-month follow-up study of patients with chronic heart failure. J Card Fail 2002;8:63-70.
    • (2002) J Card Fail , vol.8 , pp. 63-70
    • Magalski, A.1    Adamson, P.2    Gadler, F.3    Boehm, M.4    Steinhaus, D.5    Reynolds, D.6
  • 14
    • 34447504020 scopus 로고    scopus 로고
    • Right ventricular pressure waveform and wave reflection analysis in patients with pul-monary arterial hypertension
    • Karamanoglu M, McGoon M, Frantz RP, Benza RL, Bourge RC, Barst RJ et al. Right ventricular pressure waveform and wave reflection analysis in patients with pul-monary arterial hypertension. Chest 2007;132:37-43.
    • (2007) Chest , vol.132 , pp. 37-43
    • Karamanoglu, M.1    McGoon, M.2    Frantz, R.P.3    Benza, R.L.4    Bourge, R.C.5    Barst, R.J.6
  • 15
    • 77954853109 scopus 로고    scopus 로고
    • Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients
    • Stahlberg M, Damgaard M, Ersgard D, Norsk P, Karamanoglu M, Linde C et al. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients. Scand Cardiovasc J 2010; 44: 201-8.
    • (2010) Scand Cardiovasc J , vol.44 , pp. 201-8
    • Stahlberg, M.1    Damgaard, M.2    Ersgard, D.3    Norsk, P.4    Karamanoglu, M.5    Linde, C.6
  • 16
    • 39749173078 scopus 로고    scopus 로고
    • Endomyocardial upregulation ofbeta1 adrenoreceptor gene expression and myo-cardial contractile reserve following cardiac resynchronization therapy
    • Vanderheyden M, Mullens W, Delrue L, Goethals M, Verstreken S, Wijns W et al. Endomyocardial upregulation ofbeta1 adrenoreceptor gene expression and myo-cardial contractile reserve following cardiac resynchronization therapy.J Card Fail 2008;14:172-8.
    • (2008) J Card Fail , vol.14 , pp. 172-8
    • Vanderheyden, M.1    Mullens, W.2    Delrue, L.3    Goethals, M.4    Verstreken, S.5    Wijns, W.6
  • 17
    • 42649144122 scopus 로고    scopus 로고
    • Stimulation rate and the optimal interven-tricular interval during cardiac resynchronization therapy in patients with chronic atrial fibrillation
    • van Gelder BM, Meijer A, Bracke FA. Stimulation rate and the optimal interven-tricular interval during cardiac resynchronization therapy in patients with chronic atrial fibrillation. Pacing Clin Electrophysiol 2008;31:569-74.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 569-74
    • Van Gelder, B.M.1    Meijer, A.2    Bracke, F.A.3
  • 18
    • 26244457597 scopus 로고    scopus 로고
    • Myocardial contractility in the echo lab: Molecular, cellular and pathophysiological basis
    • Bombardini T. Myocardial contractility in the echo lab: molecular, cellular and pathophysiological basis. Cardiovasc Ultrasound 2005;3:27.
    • (2005) Cardiovasc Ultrasound , vol.3 , pp. 27
    • Bombardini, T.1
  • 19
    • 34250372861 scopus 로고    scopus 로고
    • Therapeutic and diagnostic role of electrical devices in acute heart failure
    • Braunschweig F. Therapeutic and diagnostic role of electrical devices in acute heart failure. Heart Fail Rev 2007;12:157-66.
    • (2007) Heart Fail Rev , vol.12 , pp. 157-66
    • Braunschweig, F.1
  • 21
    • 0034595288 scopus 로고    scopus 로고
    • Reducing cardiac filling pressure lowers norepinephrine spillover in patients with chronic heart failure
    • Azevedo ER, Newton GE, Floras JS, Parker JD. Reducing cardiac filling pressure lowers norepinephrine spillover in patients with chronic heart failure. Circulation 2000;101:2053-9.
    • (2000) Circulation , vol.101 , pp. 2053-9
    • Azevedo, E.R.1    Newton, G.E.2    Floras, J.S.3    Parker, J.D.4
  • 22
    • 0018447094 scopus 로고
    • A quantitative study of muscle nerve sympathetic activity in resting normotensive and hypertensive subjects
    • Wallin BG, Sundlof G. A quantitative study of muscle nerve sympathetic activity in resting normotensive and hypertensive subjects. Hypertension 1979;1:67-77.
    • (1979) Hypertension , vol.1 , pp. 67-77
    • Wallin, B.G.1    Sundlof, G.2
  • 23
    • 54049113533 scopus 로고    scopus 로고
    • The acute effect of atrioventricular pacing on sympathetic nerve activity in patients with normal and depressed left ventricular function
    • Segerson NM, Wasmund SL, Daccarett M, Fabela ML, Hammond CH, Stoddard G et al. The acute effect of atrioventricular pacing on sympathetic nerve activity in patients with normal and depressed left ventricular function. Am J Physiol Heart Circ Physiol 2008;295:H1076-80.
    • (2008) Am J Physiol Heart Circ Physiol , vol.295
    • Segerson, N.M.1    Wasmund, S.L.2    Daccarett, M.3    Fabela, M.L.4    Hammond, C.H.5    Stoddard, G.6
  • 25
    • 63049089345 scopus 로고    scopus 로고
    • Shorter AV delays provide improved echocardiographic hemodynamics during exercise in patients receiving cardiac resynchronization therapy
    • Grimm RA, Sun JP, Agler D, Fitzgerald B, Wilkoff B, Hilpisch K et al. Shorter AV delays provide improved echocardiographic hemodynamics during exercise in patients receiving cardiac resynchronization therapy. Pacing Clin Electrophysiol 2009;32:457-65.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 457-65
    • Grimm, R.A.1    Sun, J.P.2    Agler, D.3    Fitzgerald, B.4    Wilkoff, B.5    Hilpisch, K.6
  • 26
    • 52949130178 scopus 로고    scopus 로고
    • Cardiac resynchronization therapy during rest and exercise: Comparison of two optimization methods
    • Valzania C, Eriksson MJ, Boriani G, Gadler F. Cardiac resynchronization therapy during rest and exercise: comparison of two optimization methods. Europace 2008;10:1161-9.
    • (2008) Europace , vol.10 , pp. 1161-9
    • Valzania, C.1    Eriksson, M.J.2    Boriani, G.3    Gadler, F.4
  • 27
  • 28
    • 70349593457 scopus 로고    scopus 로고
    • Cardiac output response to changes of the atrioventricular delay in different body pos-itions and during exercise in patients receiving cardiac resynchronization therapy
    • Stahlberg M, Damgaard M, Norsk P, Gabrielsen A, Sahlen A, Linde C et al. Cardiac output response to changes of the atrioventricular delay in different body pos-itions and during exercise in patients receiving cardiac resynchronization therapy. Europace 2009; 11: 1160-7.
    • (2009) Europace , vol.11 , pp. 1160-7
    • Stahlberg, M.1    Damgaard, M.2    Norsk, P.3    Gabrielsen, A.4    Sahlen, A.5    Linde, C.6
  • 29
    • 0037454083 scopus 로고    scopus 로고
    • Ongoing right ventricular hemodynamics in heart failure: Clinical value of measurements derived from an implantable monitoring system
    • Adamson PB, Magalski A, Braunschweig F, Bohm M, Reynolds D, Steinhaus D et al. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.J Am Coll Cardiol 2003;41:565-71.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 565-71
    • Adamson, P.B.1    Magalski, A.2    Braunschweig, F.3    Bohm, M.4    Reynolds, D.5    Steinhaus, D.6
  • 30
    • 40649118759 scopus 로고    scopus 로고
    • Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The COMPASS-HF study
    • Bourge RC, Abraham WT, Adamson PB, Aaron MF, Aranda JM Jr, Magalski A et al. Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: the COMPASS-HF study.J Am Coll Cardiol 2008;51:1073-9.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1073-9
    • Bourge, R.C.1    Abraham, W.T.2    Adamson, P.B.3    Aaron, M.F.4    Aranda Jr., J.M.5    Magalski, A.6
  • 31
    • 36749017977 scopus 로고    scopus 로고
    • Reducing events in patients with chronic heart failure (REDUCEhf) study design: Continuous hemodynamic monitoring with an implantable defibrillator
    • Adamson PB, Conti JB, Smith AL, Abraham WT, Aaron MF, Aranda JM Jr et al. Reducing events in patients with chronic heart failure (REDUCEhf) study design: continuous hemodynamic monitoring with an implantable defibrillator. Clin Cardiol 2007;30:567-75.
    • (2007) Clin Cardiol , vol.30 , pp. 567-75
    • Adamson, P.B.1    Conti, J.B.2    Smith, A.L.3    Abraham, W.T.4    Aaron, M.F.5    Aranda Jr., J.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.