메뉴 건너뛰기




Volumn 1, Issue 2, 1999, Pages 126-130

Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurements

Author keywords

Acceleration echocardiography; Atrio ventricular delay; Dual chamber pacing; Haemodynamics; Peak endocardial; Sensors

Indexed keywords

ARTICLE; COMPARATIVE STUDY; HEART ATRIOVENTRICULAR NODE; HEART BLOCK; HEART PACING; HEMODYNAMICS; HUMAN; METHODOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY; QUALITY OF LIFE;

EID: 0033108072     PISSN: 10995129     EISSN: None     Source Type: Journal    
DOI: 10.1053/eupc.1998.0032     Document Type: Article
Times cited : (199)

References (13)
  • 1
    • 0013882621 scopus 로고
    • The importance of the contribution and timing of left atrial systole
    • Carleton RA, Passovoy M, Graettinger JS. The importance of the contribution and timing of left atrial systole. Clin Sci. 30:1966;151-159.
    • (1966) Clin Sci , vol.30 , pp. 151-159
    • Carleton, R.A.1    Passovoy, M.2    Graettinger, J.S.3
  • 2
    • 0024502755 scopus 로고
    • Optimal atrio-ventricular delay at rest and during exercise in patients with dual chamber pacemakers: A non-invasive assessment by continuous wave Doppler
    • Mehta D, Gilmour S, Ward DE. Optimal atrio-ventricular delay at rest and during exercise in patients with dual chamber pacemakers: a non-invasive assessment by continuous wave Doppler. Br Heart. 61:1989;161-166.
    • (1989) Br Heart , vol.61 , pp. 161-166
    • Mehta, D.1    Gilmour, S.2    Ward, D.E.3
  • 3
    • 0039543281 scopus 로고
    • Haemodynamic consequences of the timing of atrial contraction during complete atrioventricular block
    • Ronaszeki A. Haemodynamic consequences of the timing of atrial contraction during complete atrioventricular block. Acta Biomedica Lovaniensia. 15:1989.
    • (1989) Acta Biomedica Lovaniensia , vol.15
    • Ronaszeki, A.1
  • 4
    • 0025346555 scopus 로고
    • Etude par écho-Döppler des variations hémodynamiques entre modes double-stimulation et détection de l'oreillette chez des patients porteurs d'un stimulateur double chambre
    • Rey JL, Slama MA, Triboulloy C. Etude par écho-Döppler des variations hémodynamiques entre modes double-stimulation et détection de l'oreillette chez des patients porteurs d'un stimulateur double chambre. Arch Mal C\kur. 83:1990;961-966.
    • (1990) Arch Mal C\kur , vol.83 , pp. 961-966
    • Rey, J.L.1    Slama, M.A.2    Triboulloy, C.3
  • 5
    • 0001905029 scopus 로고
    • Rate-adaptive atrio-ventricular delay improves cardiopulmonary performance in patients implanted with a dual chamber pacemaker for complete heart block
    • Ritter P, Vai F, Bonnet JL. Rate-adaptive atrio-ventricular delay improves cardiopulmonary performance in patients implanted with a dual chamber pacemaker for complete heart block. EurJ Cardiac Pacing Electrophysiol. 1:1991;31-38.
    • (1991) EurJ Cardiac Pacing Electrophysiol , vol.1 , pp. 31-38
    • Ritter, P.1    Vai, F.2    Bonnet, J.L.3
  • 6
    • 0025652189 scopus 로고
    • Sympathetic nervous system response to dynamic exercise in complete AV block patients treated with AV synchronous pacing with fixed or with auto-AV delay
    • Igawa O, Tomokuni A, Saitoh M. Sympathetic nervous system response to dynamic exercise in complete AV block patients treated with AV synchronous pacing with fixed or with auto-AV delay. PACE. 13:1990;1766-1772.
    • (1990) PACE , vol.13 , pp. 1766-1772
    • Igawa, O.1    Tomokuni, A.2    Saitoh, M.3
  • 7
    • 0025681753 scopus 로고
    • C-AMP and ANP levels in VVI and DDD pacing with different AV delays during daily activity and exercise
    • Theodorakis G, Kremastinos D, Markianos M. C-AMP and ANP levels in VVI and DDD pacing with different AV delays during daily activity and exercise. PACE. 13:1990;1773-1778.
    • (1990) PACE , vol.13 , pp. 1773-1778
    • Theodorakis, G.1    Kremastinos, D.2    Markianos, M.3
  • 8
    • 0013049133 scopus 로고    scopus 로고
    • Single sensor and multisensor technology. Where we are?
    • Santini, M, Armonk, New York Futura Media Services Inc. 73
    • Garberoglio, B, Plicchi, G, Gaggini, G, Single sensor and multisensor technology. Where we are?, Santini, M, Progress in Clinical Pacing, Armonk, New York Futura Media Services Inc. 1996, 165, 73.
    • (1996) Progress in Clinical Pacing , pp. 165
    • Garberoglio, B.1    Plicchi, G.2    Gaggini, G.3
  • 9
    • 0040728673 scopus 로고
    • Implantable radiotelemetry system (IRS) for peak endocardial acceleration (PEA) measurements on free sheep (Abstr)
    • Rickards AF, Bombardini T, Corbucci G. Implantable radiotelemetry system (IRS) for peak endocardial acceleration (PEA) measurements on free sheep (Abstr). Eur J Cardiac Pacing Electrophysiol. 4:1994;60.
    • (1994) Eur J Cardiac Pacing Electrophysiol , vol.4 , pp. 60
    • Rickards, A.F.1    Bombardini, T.2    Corbucci, G.3
  • 10
    • 0002461946 scopus 로고    scopus 로고
    • Cardiac contrac-tility: Concepts and advances in implantable system applications
    • Adornato, E, Roma, Edizioni Luigi Pozzi, 96
    • Menozzi, C, Tomasi, C, Brignole, M, Cardiac contrac-tility: Concepts and advances in implantable system applications, Adornato, E, Therapies for Cardiac Arrhythmias in 1996: Where are we going?, Roma, Edizioni Luigi Pozzi, 1996, 383, 96.
    • (1996) Therapies for Cardiac Arrhythmias in 1996: Where Are We Going? , pp. 383
    • Menozzi, C.1    Tomasi, C.2    Brignole, M.3
  • 11
    • 0031785426 scopus 로고    scopus 로고
    • Dual-chamber rate responsive pacing system driven by contractility. Final assessment after 1-year follow-up
    • Clémenty J. Dual-chamber rate responsive pacing system driven by contractility. Final assessment after 1-year follow-up. PACE. 21:1998;2192-2197.
    • (1998) PACE , vol.21 , pp. 2192-2197
    • Clémenty, J.1
  • 12
    • 0031782333 scopus 로고    scopus 로고
    • For European PEA Clinical Investigation Group. Peak endocardial acceleration-based clinical testing of the |LLBEST|L: DDDR pacemaker
    • Langenfeld H, Krein A, Kirstein M, Binner L. For European PEA Clinical Investigation Group. Peak endocardial acceleration-based clinical testing of the |LLBEST|L: DDDR pacemaker. PACE. 21:1998;2187-2191.
    • (1998) PACE , vol.21 , pp. 2187-2191
    • Langenfeld, H.1    Krein, A.2    Kirstein, M.3    Binner, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.