1
-
-
33845650658
-
An in vitro patientspecific biological model of the cerebral artery reproduced with a membranous configuration for simulating endovascular ntervention
-
S. Ikeda, F. Arai, T. Fukuda, M. Negoro, K. Irie, "An in vitro patientspecific biological model of the cerebral artery reproduced with a membranous configuration for simulating endovascular ntervention, " J Robotics and Mechatronics, vol. 17, no. 3, pp. 327-333, 2005.
-
(2005)
J Robotics and Mechatronics
, vol.17
, Issue.3
, pp. 327-333
-
-
Ikeda, S.1
Arai, F.2
Fukuda, T.3
Negoro, M.4
Irie, K.5
-
2
-
-
38949198763
-
Numerical evaluation method for catheter prototypes using photoelastic stress analysis on patient-specific vascular model
-
C. Tercero, Y. Okada, S. Ikeda, T. Fukuda, K. Sekiyama, M. Negoro, I. Takahashi. "Numerical evaluation method for catheter prototypes using photoelastic stress analysis on patient-specific vascular model, " Int. J. of Medical Robotics and Computer Assisted Surgery, Vol.3:4 pp. 349-354, 2007.
-
(2007)
Int. J. of Medical Robotics and Computer Assisted Surgery
, vol.3
, Issue.4
, pp. 349-354
-
-
Tercero, C.1
Okada, Y.2
Ikeda, S.3
Fukuda, T.4
Sekiyama, K.5
Negoro, M.6
Takahashi, I.7
-
3
-
-
34248153080
-
Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery
-
C. Tercero, S. Ikeda, T. Uchiyama, T. Fukuda, F. Arai, Y. Okada, Y. Ono, R. Hattori, T. Yamamoto, M. Negoro, I. Takahashi. "Autonomous Catheter Insertion System using Magnetic Motion Capture Sensor for endovascular surgery, " International Journal of Medical Robotics and Computer Assisted Surgery. Vol. 3:1 pp 52-58, 2007.
-
(2007)
International Journal of Medical Robotics and Computer Assisted Surgery
, vol.3
, Issue.1
, pp. 52-58
-
-
Tercero, C.1
Ikeda, S.2
Uchiyama, T.3
Fukuda, T.4
Arai, F.5
Okada, Y.6
Ono, Y.7
Hattori, R.8
Yamamoto, T.9
Negoro, M.10
Takahashi, I.11
-
4
-
-
84881468373
-
Photoelastic stress analysis error quantification in vasculature models for robot feedback control
-
in press
-
C. Tercero, S. Ikeda, M. Matsushima, T. Fukuda, M. Negoro. " Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback Control, " IEEE Trans. on Mechatronics, in press.
-
IEEE Trans. on Mechatronics
-
-
Tercero, C.1
Ikeda, S.2
Matsushima, M.3
Fukuda, T.4
Negoro, M.5
-
5
-
-
77955232443
-
Human blood pressure simulation for stress analysis in model of vasculature using photoelastic effect
-
C. Tercero, S. Ikeda, E. Tijerino, M. Matsushima, T. Fukuda, M. Negoro, I. Takahashi. "Human Blood Pressure Simulation for Stress Analysis in Model of Vasculature using Photoelastic Effect" Int. J. Of Automation Technology. Vol.3 :5, 2009, pp. 533-540.
-
(2009)
Int. J. of Automation Technology
, vol.3
, Issue.5
, pp. 533-540
-
-
Tercero, C.1
Ikeda, S.2
Tijerino, E.3
Matsushima, M.4
Fukuda, T.5
Negoro, M.6
Takahashi, I.7
-
6
-
-
0004276538
-
-
Wiley-Interscience Publication, 263- 274
-
A. Kuske, G. Robertson, Photoelastic stress analysis, Wiley-Interscience Publication, 1974, pp. 87-109, 263- 274.
-
(1974)
Photoelastic Stress Analysis
, pp. 87-109
-
-
Kuske, A.1
Robertson, G.2
-
8
-
-
0032168757
-
A photoelastic study of ligament strain
-
S. Hirokawa, K. Yamamoto, T. Kawada. "A photoelastic study of ligament strain, " IEEE Trans. on Rehabilitation Eng., Vol. 6, No.3, pp. 300-308, 1998.
-
(1998)
IEEE Trans. on Rehabilitation Eng
, vol.6
, Issue.3
, pp. 300-308
-
-
Hirokawa, S.1
Yamamoto, K.2
Kawada, T.3
-
9
-
-
0033933783
-
Femoral surface strain in intact composite femurs
-
M. Grecula, R. Morris, J. Laughlin, W. Buford, R. Patterson. "Femoral Surface Strain in Intact Composite Femurs, " IEEE Trans. on Biomedical Eng., Vol. 47, No.7, pp. 926-933, 2000.
-
(2000)
IEEE Trans. on Biomedical Eng
, vol.47
, Issue.7
, pp. 926-933
-
-
Grecula, M.1
Morris, R.2
Laughlin, J.3
Buford, W.4
Patterson, R.5
|