메뉴 건너뛰기




Volumn 111, Issue 2, 2011, Pages 244-250

Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 78651446191     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2010.08.017     Document Type: Article
Times cited : (41)

References (30)
  • 1
    • 0016052927 scopus 로고
    • Cleaning and shaping the root canal. Dent
    • H. Schilder Cleaning and shaping the root canal. Dent Clin Sao Paulo Brazil 18 1974 269 296
    • (1974) Clin Sao Paulo Brazil , vol.18 , pp. 269-296
    • Schilder, H.1
  • 2
    • 0016545006 scopus 로고
    • The effect of preparation procedures on original canal shape and on apical foramen shape
    • F. Weine, R. Kelly, and P. Lio The effect of preparation procedures on original canal shape and on apical foramen shape J Endod 1 1975 262 266
    • (1975) J Endod , vol.1 , pp. 262-266
    • Weine, F.1    Kelly, R.2    Lio, P.3
  • 3
    • 11844301053 scopus 로고    scopus 로고
    • American Association of Endodontists 7th ed. AAE Chicago
    • American Association of Endodontists Glossary of endodontic terms 7th ed. 2003 AAE Chicago
    • (2003) Glossary of Endodontic Terms
  • 4
    • 78651460052 scopus 로고    scopus 로고
    • Development and sequelae of canal transportation
    • E. Schfer, and T. Dammascke Development and sequelae of canal transportation Endod Topics 15 2009 75 90
    • (2009) Endod Topics , vol.15 , pp. 75-90
    • Schfer, E.1    Dammascke, T.2
  • 5
    • 33646851572 scopus 로고    scopus 로고
    • Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated curved root canals
    • F.J. Schirrmeister, C. Strohl, J.M. Altenburger, K. Wrbas, and E. Hellwig Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated curved root canals Oral Surg Oral Med Oral Pathol Oral Radiol Endod 101 2006 807 813
    • (2006) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.101 , pp. 807-813
    • Schirrmeister, F.J.1    Strohl, C.2    Altenburger, J.M.3    Wrbas, K.4    Hellwig, E.5
  • 6
    • 25844460617 scopus 로고    scopus 로고
    • Comparative study of six rotary nickel titanium systems and hand instrumentation for root canal preparation
    • A. Guelzow, O. Stamm, P. Martus, and A.M. Kielbassa Comparative study of six rotary nickel titanium systems and hand instrumentation for root canal preparation Int Endod J 38 2005 743 752
    • (2005) Int Endod J , vol.38 , pp. 743-752
    • Guelzow, A.1    Stamm, O.2    Martus, P.3    Kielbassa, A.M.4
  • 7
    • 0024011031 scopus 로고
    • A comparison of the effect of modified and non-modified instrument tips on apical canal configuration: Part II
    • S.E. Powell, P.D. Wong, and J.H.S. Simon A comparison of the effect of modified and non-modified instrument tips on apical canal configuration Part II J Endod 14 1988 224 228
    • (1988) J Endod , vol.14 , pp. 224-228
    • Powell, S.E.1    Wong, P.D.2    Simon, J.H.S.3
  • 8
    • 0032062745 scopus 로고    scopus 로고
    • Comparison of the performance of four files with rounded tips during shaping of simulated root canals
    • P.M.H. Dummer, M.A.O. Al-Omari, and S. Bryant Comparison of the performance of four files with rounded tips during shaping of simulated root canals J Endod 24 1998 364 371
    • (1998) J Endod , vol.24 , pp. 364-371
    • Dummer, P.M.H.1    Al-Omari, M.A.O.2    Bryant, S.3
  • 9
    • 0026247822 scopus 로고
    • The radiographic platform: A new method to evaluate root canal preparation
    • G.B. Sydney, A. Batista, and L.L. Melo The radiographic platform: a new method to evaluate root canal preparation J Endod 17 1991 570 572
    • (1991) J Endod , vol.17 , pp. 570-572
    • Sydney, G.B.1    Batista, A.2    Melo, L.L.3
  • 10
    • 0023336237 scopus 로고
    • A methodology for evaluation of root canal instrumentation
    • C.M. Bramante, A. Berbert, and R.P. Borges A methodology for evaluation of root canal instrumentation J Endod 13 1987 243 245
    • (1987) J Endod , vol.13 , pp. 243-245
    • Bramante, C.M.1    Berbert, A.2    Borges, R.P.3
  • 11
    • 0033169726 scopus 로고    scopus 로고
    • A new method to assess the results of instrumentation techniques in the root canal
    • C.R. Barthel, S. Gruber, and J.F. Roulet A new method to assess the results of instrumentation techniques in the root canal J Endod 25 1999 535 538
    • (1999) J Endod , vol.25 , pp. 535-538
    • Barthel, C.R.1    Gruber, S.2    Roulet, J.F.3
  • 12
    • 34447631029 scopus 로고    scopus 로고
    • Canal transportation after root canal instrumentation: A comparative study with computed tomography
    • M.S.M. Hartmann, F.B. Barletta, V.R.C. Fontanella, and J.R. Vanni Canal transportation after root canal instrumentation: a comparative study with computed tomography J Endod 33 2007 962 965
    • (2007) J Endod , vol.33 , pp. 962-965
    • Hartmann, M.S.M.1    Barletta, F.B.2    Fontanella, V.R.C.3    Vanni, J.R.4
  • 13
    • 57649149926 scopus 로고    scopus 로고
    • A preliminary study of the use of peripheral quantitative computed tomography for investigating root canal anatomy
    • M.T. Sberna, G. Rizzo, E. Zacchi, P. Cappar, and A. Rubinacci A preliminary study of the use of peripheral quantitative computed tomography for investigating root canal anatomy Int Endod J 42 2008 66 75
    • (2008) Int Endod J , vol.42 , pp. 66-75
    • Sberna, M.T.1    Rizzo, G.2    Zacchi, E.3    Cappar, P.4    Rubinacci, A.5
  • 14
    • 78049283288 scopus 로고    scopus 로고
    • Root canal area increase promoted by the endosequence and ProTaper systems: Comparison by computed tomography
    • R.A. Bernardes, E. Antunes, M.A.H. Duarte, R.R. Vivan, I.G. deMoraes, and A.S. Bramante Root canal area increase promoted by the endosequence and ProTaper systems: comparison by computed tomography J Endod 2010 [Epub ahead of print]
    • (2010) J Endod
    • Bernardes, R.A.1    Antunes, E.2    Duarte, M.A.H.3    Vivan, R.R.4    Demoraes, I.G.5    Bramante, A.S.6
  • 15
    • 77950937497 scopus 로고    scopus 로고
    • Comparison of canal transportation and centering ability of twisted files, pathfile-ProTaper system, and stainless steel hand k-files by using computed tomography
    • R. Gergi, J.A. Rjeily, J. Sader, and A. Naaman Comparison of canal transportation and centering ability of twisted files, pathfile-ProTaper system, and stainless steel hand k-files by using computed tomography J Endod 36 2010 904
    • (2010) J Endod , vol.36 , pp. 904
    • Gergi, R.1    Rjeily, J.A.2    Sader, J.3    Naaman, A.4
  • 16
    • 61449286055 scopus 로고    scopus 로고
    • Method for determination of root curvature radius using cone-beam computed tomography images
    • C. Estrela, M.R. Bueno, M.D. Sousa-Neto, and J.D. Pcora Method for determination of root curvature radius using cone-beam computed tomography images Braz Dent J 2 2008 114 118
    • (2008) Braz Dent J , vol.2 , pp. 114-118
    • Estrela, C.1    Bueno, M.R.2    Sousa-Neto, M.D.3    Pcora, J.D.4
  • 17
    • 0038146984 scopus 로고    scopus 로고
    • ProTaper rotary root canal preparation: Effects of canal anatomy on final shape analyzed by micro CT
    • O.A. Peters, C.I. Peters, K. Schnenberger, and F. Barbakow ProTaper rotary root canal preparation: effects of canal anatomy on final shape analyzed by micro CT Int Endod 36 J 2003 86 92
    • (2003) Int Endod , vol.36 , pp. 86-92
    • Peters, O.A.1    Peters, C.I.2    Schnenberger, K.3    Barbakow, F.4
  • 18
    • 58249105404 scopus 로고    scopus 로고
    • An application framework of three-dimensional reconstruction and measurement for endodontic research
    • Y. Gao, O.A. Peters, H. Wu, and X. Zhou An application framework of three-dimensional reconstruction and measurement for endodontic research J Endod 35 2009 269 274
    • (2009) J Endod , vol.35 , pp. 269-274
    • Gao, Y.1    Peters, O.A.2    Wu, H.3    Zhou, X.4
  • 19
    • 71849103328 scopus 로고    scopus 로고
    • Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model
    • A. Wenzel, F. Haiter-Neto, M. Frydenberg, and L.-L. Kirkevang Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model Oral Surg Oral Med Oral Pathol Oral Radiol Endod 108 2009 939 945
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.108 , pp. 939-945
    • Wenzel, A.1    Haiter-Neto, F.2    Frydenberg, M.3    Kirkevang, L.-L.4
  • 20
    • 0032128909 scopus 로고    scopus 로고
    • Shaping ability of profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals
    • S.T. Bryant, S.A. Thompson, M.A.O. Al-Omari, and P.M.H. Dummer Shaping ability of profile rotary nickel-titanium instruments with ISO sized tips in simulated root canals Int Endod J 31 1998 275 281
    • (1998) Int Endod J , vol.31 , pp. 275-281
    • Bryant, S.T.1    Thompson, S.A.2    Al-Omari, M.A.O.3    Dummer, P.M.H.4
  • 21
    • 0027564129 scopus 로고
    • Comparison of root canal preparation using different automated device and hand instrumentation
    • M. Hlsman, and F. Stryga Comparison of root canal preparation using different automated device and hand instrumentation J Endod 19 1993 141 145
    • (1993) J Endod , vol.19 , pp. 141-145
    • Hlsman, M.1    Stryga, F.2
  • 22
    • 0035288583 scopus 로고    scopus 로고
    • Comparing apical preparations of root canals shaped by nickel-titanium rotary-instruments and nickel-titanium hand instruments
    • P. Deplazes, O. Peters, and F. Barbakow Comparing apical preparations of root canals shaped by nickel-titanium rotary-instruments and nickel-titanium hand instruments J Endod 27 2001 196 202
    • (2001) J Endod , vol.27 , pp. 196-202
    • Deplazes, P.1    Peters, O.2    Barbakow, F.3
  • 23
    • 0035236239 scopus 로고    scopus 로고
    • Changes in root canal geometry after preparation assessed by high-resolution computed tomography
    • O.A. Peters, A. Laib, T.N. Ghring, and F. Barbakow Changes in root canal geometry after preparation assessed by high-resolution computed tomography J Endod 27 2001 1 6 (Pubitemid 33753586)
    • (2001) Journal of Endodontics , vol.27 , Issue.1 , pp. 1-6
    • Peters, O.A.1    Laib, A.2    Gohring, T.N.3    Barbakow, F.4
  • 24
    • 33646051843 scopus 로고    scopus 로고
    • Determination of the minimum instrumentation size for penetration of irrigants to the apical third of root canal systems
    • A. Khademi, M. Yazdizadeh, and M. Feizianfard Determination of the minimum instrumentation size for penetration of irrigants to the apical third of root canal systems J Endod 32 2006 417 420
    • (2006) J Endod , vol.32 , pp. 417-420
    • Khademi, A.1    Yazdizadeh, M.2    Feizianfard, M.3
  • 25
    • 0030320582 scopus 로고    scopus 로고
    • Effect of four instrumentation techniques on curved canals: A comparison study
    • E. Schfer Effect of four instrumentation techniques on curved canals: a comparison study J Endod 22 1996 685 690
    • (1996) J Endod , vol.22 , pp. 685-690
    • Schfer, E.1
  • 26
    • 33847230225 scopus 로고    scopus 로고
    • A comparison of three NiTi rotary instruments in apical transportation
    • H.H. Javaheri, and G.H. Javaheri A comparison of three NiTi rotary instruments in apical transportation J Endod 33 2007 284 286
    • (2007) J Endod , vol.33 , pp. 284-286
    • Javaheri, H.H.1    Javaheri, G.H.2
  • 27
    • 0034230985 scopus 로고    scopus 로고
    • Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal models
    • Y.L. Turpin, F. Chagneau, and J.M. Vulcain Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal models J Endod 26 2000 414 417
    • (2000) J Endod , vol.26 , pp. 414-417
    • Turpin, Y.L.1    Chagneau, F.2    Vulcain, J.M.3
  • 28
    • 77649203216 scopus 로고    scopus 로고
    • Evaluation of the centering ability of the ProTaper universal rotary system in curved roots in comparison to nitiflex files
    • C.M. Aguiar, D.A. Mendes, A.C. Cmara, and J.A.P. Figueiredo Evaluation of the centering ability of the ProTaper universal rotary system in curved roots in comparison to nitiflex files Aust Endod J 35 2009 174 179
    • (2009) Aust Endod J , vol.35 , pp. 174-179
    • Aguiar, C.M.1    Mendes, D.A.2    Cmara, A.C.3    Figueiredo, J.A.P.4
  • 29
    • 57649239413 scopus 로고    scopus 로고
    • Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments
    • J. Vaudt, K. Bitter, K. Neumann, and M. Kielbassa Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments Int Endod J 42 2009 22 33
    • (2009) Int Endod J , vol.42 , pp. 22-33
    • Vaudt, J.1    Bitter, K.2    Neumann, K.3    Kielbassa, M.4
  • 30
    • 57149126344 scopus 로고    scopus 로고
    • Flexibility and torsional strength of protaper and protaper universal rotary instruments assessed by mechanical tests
    • A.S. Cmara, R. de Castro Martins, A.C.D. Viana, L.R. de Toledo, V.T.L. Buono, and M.G. de Azevedo Bahia Flexibility and torsional strength of protaper and protaper universal rotary instruments assessed by mechanical tests J Endod 35 2009 113 116
    • (2009) J Endod , vol.35 , pp. 113-116
    • Cmara, A.S.1    De Castro Martins, R.2    Viana, A.C.D.3    De Toledo, L.R.4    Buono, V.T.L.5    De Azevedo Bahia, M.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.