-
1
-
-
58249094600
-
A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: Is digital templating accurate and safe
-
published online ahead of print March 28, 2008
-
Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe [published online ahead of print March 28, 2008]? J Arthroplasty. 2009; 24(2):175-179.
-
(2009)
J Arthroplasty
, vol.24
, Issue.2
, pp. 175-179
-
-
Iorio, R.1
Siegel, J.2
Specht, L.M.3
Tilzey, J.F.4
Hartman, A.5
Healy, W.L.6
-
2
-
-
35848961458
-
A comparison of acetate and digital templating for total knee arthroplasty
-
DOI 10.1097/BLO.0b013e3181560d74, PII 0000308620071100000028
-
Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF. A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop Relat Res. 2007; (464):179-183. (Pubitemid 350059964)
-
(2007)
Clinical Orthopaedics and Related Research
, Issue.464
, pp. 179-183
-
-
Specht, L.M.1
Levitz, S.2
Iorio, R.3
Healy, W.L.4
Tilzey, J.F.5
-
3
-
-
0036155771
-
Kinemax total knee arthroplasty: Trial by template
-
DOI 10.1054/arth.2002.27258
-
Heal J, Blewitt N. Kinemax total knee arthroplasty: trial by template. J Arthroplasty. 2002; 17(1):90-94. (Pubitemid 34098209)
-
(2002)
Journal of Arthroplasty
, vol.17
, Issue.1
, pp. 90-94
-
-
Heal, J.1
Blewitt, N.2
-
4
-
-
54949157701
-
Digital preoperative templating is more accurate in total hip replacement compared to analogue templating
-
Hossain M, Lewis J, Sinha A. Digital preoperative templating is more accurate in total hip replacement compared to analogue templating. Eur J Orthop Surg Traumatol. 2008; (18):577-580.
-
(2008)
Eur J Orthop Surg Traumatol
, Issue.18
, pp. 577-580
-
-
Hossain, M.1
Lewis, J.2
Sinha, A.3
-
5
-
-
46749145323
-
Comparison of digital and plain radiography preoperative templating in total knee arthroplasty
-
Lewis J, Hossain M, Mustafa A, Sinha A. Comparison of digital and plain radiography preoperative templating in total knee arthroplasty. Eur J Orthop Surg Traumatol. 2008; (18):357-360.
-
(2008)
Eur J Orthop Surg Traumatol
, Issue.18
, pp. 357-360
-
-
Lewis, J.1
Hossain, M.2
Mustafa, A.3
Sinha, A.4
-
6
-
-
14744289111
-
Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees
-
The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop. 2005; 76(1):78-84.
-
(2005)
Acta Orthop
, vol.76
, Issue.1
, pp. 78-84
-
-
The, B.1
Diercks, R.L.2
Van Ooijen, P.M.3
Van Horn, J.R.4
-
7
-
-
34548428628
-
Digital versus analogue preoperative planning of total hip arthroplasties: A randomized clinical trial of 210 total hip arthroplasties
-
published online ahead of print March 28, 2007
-
The B, Verdonschot N, van Horn JR, van Ooijen PM, Diercks RL. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties [published online ahead of print March 28, 2007]. J Arthroplasty. 2007; 22(6):866-870.
-
(2007)
J Arthroplasty
, vol.22
, Issue.6
, pp. 866-870
-
-
The, B.1
Verdonschot, N.2
Van Horn, J.R.3
Van Ooijen, P.M.4
Diercks, R.L.5
-
8
-
-
67650152609
-
The reliability and accuracy of digital templating in total knee replacement
-
Trickett RW, Hodgson P, Forster MC, Robertson A. The reliability and accuracy of digital templating in total knee replacement. J Bone Joint Surg Br. 2009; 91(7):903-906.
-
(2009)
J Bone Joint Surg Br
, vol.91
, Issue.7
, pp. 903-906
-
-
Trickett, R.W.1
Hodgson, P.2
Forster, M.C.3
Robertson, A.4
-
9
-
-
77953123002
-
The accuracy of digital templating in uncemented total hip arthroplasty
-
published online of print June 2, 2009
-
Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty [published online of print June 2, 2009]. J Arthroplasty. 2010; 25(4):529-532.
-
(2010)
J Arthroplasty
, vol.25
, Issue.4
, pp. 529-532
-
-
Gamble, P.1
De Beer, J.2
Petruccelli, D.3
Winemaker, M.4
-
10
-
-
62449239421
-
A new digital preoperative planning method for total hip arthroplasties
-
published online ahead of print September 10, 2008
-
Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB. A new digital preoperative planning method for total hip arthroplasties [published online ahead of print September 10, 2008]. Clin Orthop Relat Res. 2009; 467(4):909-916.
-
(2009)
Clin Orthop Relat Res
, vol.467
, Issue.4
, pp. 909-916
-
-
Crooijmans, H.J.1
Laumen, A.M.2
Van Pul, C.3
Van Mourik, J.B.4
-
11
-
-
42449154630
-
The utility and precision of analogue and digital preoperative planning for total hip arthroplasty
-
published online ahead of print April 3, 2007
-
González Della Valle A, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty [published online ahead of print April 3, 2007]. Int Orthop. 2008; 32(3):289-294.
-
(2008)
Int Orthop
, vol.32
, Issue.3
, pp. 289-294
-
-
González Della Valle, A.1
Comba, F.2
Taveras, N.3
Salvati, E.A.4
-
12
-
-
73349097581
-
Value of preoperative templating for primary total knee arthroplasty
-
Del Gaizo D, Soileau ES, Lachiewicz PF. Value of preoperative templating for primary total knee arthroplasty. J Knee Surg. 2009; 22(4):284-293.
-
(2009)
J Knee Surg
, vol.22
, Issue.4
, pp. 284-293
-
-
Del Gaizo, D.1
Soileau, E.S.2
Lachiewicz, P.F.3
|