메뉴 건너뛰기




Volumn 93, Issue 1, 2011, Pages 11-19

Thermal effects of glenoid reaming during shoulder arthroplasty in vivo

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BULB IRRIGATION; CLINICAL ARTICLE; FEMALE; GLENOID DRILLING; GLENOID REAMING; HUMAN; MALE; OSTEOARTHRITIS; PRIORITY JOURNAL; SHOULDER ARTHROPLASTY; SHOULDER SURGERY; TEMPERATURE; THERMAL ANALYSIS;

EID: 78650941943     PISSN: 00219355     EISSN: 15351386     Source Type: Journal    
DOI: 10.2106/JBJS.I.01227     Document Type: Article
Times cited : (23)

References (58)
  • 8
    • 34548426873 scopus 로고    scopus 로고
    • Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: A prospective comparative study
    • Rosenberg N, Neumann L, Modi A, Mersich IJ, Wallace AW. Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: a prospective comparative study. BMC Musculoskelet Disord. 2007;8:76.
    • (2007) BMC Musculoskelet Disord , vol.8 , pp. 76
    • Rosenberg, N.1    Neumann, L.2    Modi, A.3    Mersich, I.J.4    Wallace, A.W.5
  • 9
    • 0029991347 scopus 로고    scopus 로고
    • Complications of total shoulder-replacement arthroplasty
    • Wirth MA, Rockwood CA Jr. Complications of total shoulder-replacement arthroplasty. J Bone Joint Surg Am. 1996;78:603-16.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 603-616
    • Wirth, M.A.1    Rockwood Jr., C.A.2
  • 11
    • 16144367923 scopus 로고    scopus 로고
    • Measurements of shaft speed while drilling through bone
    • Abouzgia MB, James DF. Measurements of shaft speed while drilling through bone. J Oral Maxillofac Surg. 1996;54:379.
    • (1996) J Oral Maxillofac Surg , vol.54 , pp. 379
    • Abouzgia, M.B.1    James, D.F.2
  • 14
    • 0034446654 scopus 로고    scopus 로고
    • The effects of drilling force on cortical temperatures and their duration: An in vitro study
    • Bachus KN, Rondina MT, Hutchinson DT. The effects of drilling force on cortical temperatures and their duration: an in vitro study. Med Eng Phys. 2000;22:685-91.
    • (2000) Med Eng Phys , vol.22 , pp. 685-691
    • Bachus, K.N.1    Rondina, M.T.2    Hutchinson, D.T.3
  • 15
    • 0344109564 scopus 로고    scopus 로고
    • The physics of heat generation during reaming of the medullary cavity
    • Baumgart F, Kohler G, Ochsner PE. The physics of heat generation during reaming of the medullary cavity. Injury. 1998;29 Suppl 2:B11-25.
    • (1998) Injury , vol.29 , Issue.SUPPL. 2
    • Baumgart, F.1    Kohler, G.2    Ochsner, P.E.3
  • 17
    • 0038374248 scopus 로고    scopus 로고
    • Drilling in bone: Modeling heat generation and temperature distribution
    • Davidson SR, James DF. Drilling in bone: modeling heat generation and temperature distribution. J Biomech Eng. 2003;125:305-14.
    • (2003) J Biomech Eng , vol.125 , pp. 305-314
    • Davidson, S.R.1    James, D.F.2
  • 18
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit
    • Eriksson AR, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50:101-7.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, A.R.1    Albrektsson, T.2
  • 22
    • 0035512351 scopus 로고    scopus 로고
    • Effects of mechanical and thermal fatigue on dental drill performance
    • Harris BH, Kohles SS. Effects of mechanical and thermal fatigue on dental drill performance. Int J Oral Maxillofac Implants. 2001;16:819-26.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 819-826
    • Harris, B.H.1    Kohles, S.S.2
  • 23
    • 0031217840 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: relationship between drill speed and heat production. Int J Prosthodont. 1997;10:411-4.
    • (1997) Int J Prosthodont , vol.10 , pp. 411-414
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 24
    • 0031264521 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: relationship between drill speed and healing. Int J Prosthodont. 1997;10:536-40.
    • (1997) Int J Prosthodont , vol.10 , pp. 536-540
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 26
    • 0019033815 scopus 로고
    • Effect of internal irrigation on frictional heat generated from bone drilling
    • Lavelle C, Wedgwood D. Effect of internal irrigation on frictional heat generated from bone drilling. J Oral Surg. 1980;38:499-503.
    • (1980) J Oral Surg , vol.38 , pp. 499-503
    • Lavelle, C.1    Wedgwood, D.2
  • 27
    • 0021169798 scopus 로고
    • The thermal effects of skeletal fixationpin insertion in bone
    • Matthews LS, Green CA, Goldstein SA. The thermal effects of skeletal fixationpin insertion in bone. J Bone Joint Surg Am. 1984;66:1077-83.
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 1077-1083
    • Matthews, L.S.1    Green, C.A.2    Goldstein, S.A.3
  • 28
    • 0029890494 scopus 로고    scopus 로고
    • Orthopaedic bone drills - Can they be improved? Temperature changes near the drilling face
    • Natali C, Ingle P, Dowell J. Orthopaedic bone drills - can they be improved? Temperature changes near the drilling face. J Bone Joint Surg Br. 1996;78:357-62.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 357-362
    • Natali, C.1    Ingle, P.2    Dowell, J.3
  • 29
    • 0020172669 scopus 로고
    • Surgical drilling: Design and performance of an improved drill
    • Saha S, Pal S, Albright JA. Surgical drilling: design and performance of an improved drill. J Biomech Eng. 1982;104:245-52.
    • (1982) J Biomech Eng , vol.104 , pp. 245-252
    • Saha, S.1    Pal, S.2    Albright, J.A.3
  • 30
    • 0033174440 scopus 로고    scopus 로고
    • Effect of feed rate and drill speed on temperatures in equine cortical bone
    • Toews AR, Bailey JV, Townsend HG, Barber SM. Effect of feed rate and drill speed on temperatures in equine cortical bone. Am J Vet Res. 1999;60:942-4.
    • (1999) Am J Vet Res , vol.60 , pp. 942-944
    • Toews, A.R.1    Bailey, J.V.2    Townsend, H.G.3    Barber, S.M.4
  • 31
    • 0026873629 scopus 로고
    • Heat distribution in bone during preparation of implant sites: Heat analysis by real-time thermography
    • Watanabe F, Tawada Y, Komatsu S, Hata Y. Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography. Int J Oral Maxillofac Implants. 1992;7:212-9.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 212-219
    • Watanabe, F.1    Tawada, Y.2    Komatsu, S.3    Hata, Y.4
  • 32
    • 0030236835 scopus 로고    scopus 로고
    • The effect of irrigation on osteotomy depth and bur diameter
    • Yacker MJ, Klein M. The effect of irrigation on osteotomy depth and bur diameter. Int J Oral Maxillofac Implants. 1996;11:634-8.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 634-638
    • Yacker, M.J.1    Klein, M.2
  • 34
    • 34247620071 scopus 로고    scopus 로고
    • Measurement of thermal diffusivity of bone, hydroxyapatite and metals for biomedical application
    • Rodriguez GP. Measurement of thermal diffusivity of bone, hydroxyapatite and metals for biomedical application. Anal Sci. 2001;17:s126-8.
    • (2001) Anal Sci , vol.17
    • Rodriguez, G.P.1
  • 35
  • 37
    • 0029898183 scopus 로고    scopus 로고
    • Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases
    • Leunig M. Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases. J Bone Joint Surg Br. 1996;78:584-7.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 584-587
    • Leunig, M.1
  • 38
    • 51249086437 scopus 로고    scopus 로고
    • The incidence of early radiolucencies about a pegged glenoid component using cement pressurization
    • Barwood S, Setter KJ, Blaine TA, Bigliani LU. The incidence of early radiolucencies about a pegged glenoid component using cement pressurization. J Shoulder Elbow Surg. 2008;17:703-8.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 703-708
    • Barwood, S.1    Setter, K.J.2    Blaine, T.A.3    Bigliani, L.U.4
  • 39
    • 0036632076 scopus 로고    scopus 로고
    • Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: A prospective, double-blind, randomized study
    • Boileau P, Avidor C, Krishnan SG, Walch G, Kempf JF, Molé D. Cemented polyethylene versus uncemented metal-backed glenoid components in total shoulder arthroplasty: a prospective, double-blind, randomized study. J Shoulder Elbow Surg. 2002;11:351-9.
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 351-359
    • Boileau, P.1    Avidor, C.2    Krishnan, S.G.3    Walch, G.4    Kempf, J.F.5    Molé, D.6
  • 43
    • 33644681350 scopus 로고    scopus 로고
    • Hemiarthroplasty versus total shoulder prosthesis: Results of cemented glenoid components
    • Pfahler M, Jena F, Neyton L, Sirveaux F, Molé D. Hemiarthroplasty versus total shoulder prosthesis: results of cemented glenoid components. J Shoulder Elbow Surg. 2006;15:154-63.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 154-163
    • Pfahler, M.1    Jena, F.2    Neyton, L.3    Sirveaux, F.4    Molé, D.5
  • 45
    • 0036897561 scopus 로고    scopus 로고
    • The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: Results of a multicenter study
    • Walch G, Edwards TB, Boulahia A, Boileau P, Mole D, Adeleine P. The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Joint Surg Am. 2002;84:2186-91.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 2186-2191
    • Walch, G.1    Edwards, T.B.2    Boulahia, A.3    Boileau, P.4    Mole, D.5    Adeleine, P.6
  • 47
    • 0036851273 scopus 로고    scopus 로고
    • A finite element model of the shoulder: Application to the comparison of normal and osteoarthritic joints
    • Bristol, Avon
    • Büchler P, Ramaniraka NA, Rakotomanana LR, Iannotti JP, Farron A. A finite element model of the shoulder: application to the comparison of normal and osteoarthritic joints. Clin Biomech (Bristol, Avon). 2002;17:630-9.
    • (2002) Clin Biomech , vol.17 , pp. 630-639
    • Büchler, P.1    Ramaniraka, N.A.2    Rakotomanana, L.R.3    Iannotti, J.P.4    Farron, A.5
  • 48
    • 34047165210 scopus 로고    scopus 로고
    • Increased longterm failure risk associated with excessively thin cement mantle in cemented hip arthroplasty: A comparative in vitro study
    • Bristol, Avon
    • Cristofolini L, Erani P, Savigni P, Grupp T, Thies O, Viceconti M. Increased longterm failure risk associated with excessively thin cement mantle in cemented hip arthroplasty: a comparative in vitro study. Clin Biomech (Bristol, Avon). 2007;22:410-21.
    • (2007) Clin Biomech , vol.22 , pp. 410-421
    • Cristofolini, L.1    Erani, P.2    Savigni, P.3    Grupp, T.4    Thies, O.5    Viceconti, M.6
  • 49
    • 21444450654 scopus 로고    scopus 로고
    • Effects of mechanical compression of a fibrous tissue interface on bone with or without highdensity polyethylene particles in a rabbit model of prosthetic loosening
    • De Man FH, Tigchelaar W, Marti RK, Van Noorden CJ, Van der Vis HM. Effects of mechanical compression of a fibrous tissue interface on bone with or without highdensity polyethylene particles in a rabbit model of prosthetic loosening. J Bone Joint Surg Am. 2005;87:1522-33.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1522-1533
    • De Man, F.H.1    Tigchelaar, W.2    Marti, R.K.3    Van Noorden, C.J.4    Van Der Vis, H.M.5
  • 51
    • 0028500394 scopus 로고
    • Cessation of strain facilitates bone formation in the micromotion chamber implanted in the rabbit tibia
    • Goodman SB, Song Y, Doshi A, Aspenberg P. Cessation of strain facilitates bone formation in the micromotion chamber implanted in the rabbit tibia. Biomaterials. 1994;15:889-93.
    • (1994) Biomaterials , vol.15 , pp. 889-893
    • Goodman, S.B.1    Song, Y.2    Doshi, A.3    Aspenberg, P.4
  • 52
    • 0027703735 scopus 로고
    • Difference in bone ingrowth after one versus two daily episodes of micromotion: Experiments with titanium chambers in rabbits
    • Goodman S, Wang JS, Doshi A, Aspenberg P. Difference in bone ingrowth after one versus two daily episodes of micromotion: experiments with titanium chambers in rabbits. J Biomed Mater Res. 1993;27:1419-24.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1419-1424
    • Goodman, S.1    Wang, J.S.2    Doshi, A.3    Aspenberg, P.4
  • 53
    • 30744456272 scopus 로고    scopus 로고
    • The effect of cementing technique on structural fixation of pegged glenoid components in total shoulder arthroplasty
    • Nyffeler RW, Meyer D, Sheikh R, Koller BJ, Gerber C. The effect of cementing technique on structural fixation of pegged glenoid components in total shoulder arthroplasty. J Shoulder Elbow Surg. 2006;15:106-11.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 106-111
    • Nyffeler, R.W.1    Meyer, D.2    Sheikh, R.3    Koller, B.J.4    Gerber, C.5
  • 54
    • 4444256245 scopus 로고    scopus 로고
    • Stability of cemented all-polyethylene keeled glenoid components. A radiostereometric study with a two-year follow-up
    • Rahme H, Mattsson P, Larsson S. Stability of cemented all-polyethylene keeled glenoid components. A radiostereometric study with a two-year follow-up. J Bone Joint Surg Br. 2004;86:856-60.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 856-860
    • Rahme, H.1    Mattsson, P.2    Larsson, S.3
  • 55
    • 21444460798 scopus 로고    scopus 로고
    • Bone-cement interface of the glenoid component: Stress analysis for varying cement thickness
    • Bristol, Avon
    • Terrier A, Büchler P, Farron A. Bone-cement interface of the glenoid component: stress analysis for varying cement thickness. Clin Biomech (Bristol, Avon). 2005;20:710-7.
    • (2005) Clin Biomech , vol.20 , pp. 710-717
    • Terrier, A.1    Büchler, P.2    Farron, A.3
  • 56
    • 0032903899 scopus 로고    scopus 로고
    • Mechanical compression of a fibrous membrane surrounding bone causes bone resorption
    • Van der Vis HM, Aspenberg P, Tigchelaar W, Van Noorden CJ. Mechanical compression of a fibrous membrane surrounding bone causes bone resorption. Acta Histochem. 1999;101:203-12.
    • (1999) Acta Histochem , vol.101 , pp. 203-212
    • Van Der Vis, H.M.1    Aspenberg, P.2    Tigchelaar, W.3    Van Noorden, C.J.4
  • 58
    • 64449084841 scopus 로고    scopus 로고
    • Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: Preliminary report
    • Augustin G, Davila S, Udiljak T, Vedrina DS, Bagatin D. Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Arch Orthop Trauma Surg. 2009;129:703-9.
    • (2009) Arch Orthop Trauma Surg , vol.129 , pp. 703-709
    • Augustin, G.1    Davila, S.2    Udiljak, T.3    Vedrina, D.S.4    Bagatin, D.5