메뉴 건너뛰기




Volumn 16, Issue 6, 2001, Pages 819-826

Effects of Mechanical and Thermal Fatigue on Dental Drill Performance

Author keywords

Dental instruments; Mechanical stress; Operative dentistry; Torque

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPARATIVE STUDY; DENTAL CARE; DENTAL EQUIPMENT; EQUIPMENT DESIGN; HEAT; HUMAN; INSTRUMENT STERILIZATION; INSTRUMENTATION; MANDIBLE; MECHANICAL STRESS; TOOTH IMPLANTATION;

EID: 0035512351     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (45)

References (23)
  • 1
    • 0031088297 scopus 로고    scopus 로고
    • Heat generation during implant site preparation: An in vitro study
    • Cordioli G, Majzoub Z. Heat generation during implant site preparation: An in vitro study. Int J Oral Maxillofac Implants 1997;12:186-193.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 186-193
    • Cordioli, G.1    Majzoub, Z.2
  • 2
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: An experimental study in rabbits using the bone growth chamber
    • Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: An experimental study in rabbits using the bone growth chamber. J Oral Maxillofac Surg 1984;42: 705-711.
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 3
    • 0020322562 scopus 로고
    • Thermal injury to bone: A vital-microscopic description of heat effects
    • Eriksson A, Albrektsson T, Grane B, McQueen D. Thermal injury to bone: A vital-microscopic description of heat effects. Int J Oral Surg 1982;11:115-121.
    • (1982) Int J Oral Surg , vol.11 , pp. 115-121
    • Eriksson, A.1    Albrektsson, T.2    Grane, B.3    McQueen, D.4
  • 4
    • 0021712493 scopus 로고
    • Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit
    • Eriksson RA, Albrektsson T, Magnusson B. Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit. Scand J Plast Reconstr Surg 1984;18:261-268.
    • (1984) Scand J Plast Reconstr Surg , vol.18 , pp. 261-268
    • Eriksson, R.A.1    Albrektsson, T.2    Magnusson, B.3
  • 5
    • 0022069236 scopus 로고
    • Thermally induced bone necrosis in rabbits: Relation to implant failure in humans
    • Albrektsson T, Eriksson A. Thermally induced bone necrosis in rabbits: Relation to implant failure in humans. Clin Orthop 1985;May:311-312.
    • (1985) Clin Orthop , vol.MAY , pp. 311-312
    • Albrektsson, T.1    Eriksson, A.2
  • 6
    • 0031217840 scopus 로고    scopus 로고
    • Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. Int J Prosthodont 1997;10:411-414.
    • (1997) Int J Prosthodont , vol.10 , pp. 411-414
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 7
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit
    • Eriksson RA, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit. J Prosthet Dent 1983;50:101-107.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, R.A.1    Albrektsson, T.2
  • 8
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg [Am] 1972;54: 297-308.
    • (1972) J Bone Joint Surg [Am] , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 9
    • 0030236835 scopus 로고    scopus 로고
    • The effect of irrigation on osteotomy depth and bur diameter
    • Yacker M, Klein M. The effect of irrigation on osteotomy depth and bur diameter. Int J Oral Maxillofac Implants 1996;11:634-638.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 634-638
    • Yacker, M.1    Klein, M.2
  • 12
  • 13
    • 0026873629 scopus 로고
    • Heat distribution in bone during preparation of implant sites: Heat analysis by real-time thermography
    • Watanabe F, Tawada Y, Komatsu S, Hata Y. Heat distribution in bone during preparation of implant sites: Heat analysis by real-time thermography. Int J Oral Maxillofac Implants 1992;7:212-219.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 212-219
    • Watanabe, F.1    Tawada, Y.2    Komatsu, S.3    Hata, Y.4
  • 14
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • Brisman D. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996;11:35-37.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 35-37
    • Brisman, D.1
  • 15
    • 0345966170 scopus 로고    scopus 로고
    • U.S. Markets for Dental Implants and Dental Bone Substitutes. Cary, NC: Medical Data International, 1999
    • U.S. Markets for Dental Implants and Dental Bone Substitutes. Cary, NC: Medical Data International, 1999.
  • 17
    • 0017642925 scopus 로고
    • Investigation of variable factors in drilling bone
    • Hobkirk JA, Rusiniak K. Investigation of variable factors in drilling bone. J Oral Surg 1977;35:968-973.
    • (1977) J Oral Surg , vol.35 , pp. 968-973
    • Hobkirk, J.A.1    Rusiniak, K.2
  • 18
    • 0028881831 scopus 로고
    • Measurements of shaft speed while drilling through bone
    • Abouzgia MB, James DF. Measurements of shaft speed while drilling through bone. J Oral Maxillofac Surg 1995;53: 1308-1316.
    • (1995) J Oral Maxillofac Surg , vol.53 , pp. 1308-1316
    • Abouzgia, M.B.1    James, D.F.2
  • 19
    • 0031214072 scopus 로고    scopus 로고
    • Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens
    • Kohles SS, Bowers JR, Vailas AC, Vanderby R Jr. Ultrasonic wave velocity measurement in small polymeric and cortical bone specimens. J Biomech Eng 1997;119:232-236.
    • (1997) J Biomech Eng , vol.119 , pp. 232-236
    • Kohles, S.S.1    Bowers, J.R.2    Vailas, A.C.3    Vanderby Jr., R.4
  • 22
    • 0025786787 scopus 로고
    • Thermographic stress analysis in cortical bone
    • Vanderby R Jr, Kohles SS. Thermographic stress analysis in cortical bone. J Biomech Eng 1991;113:418-422.
    • (1991) J Biomech Eng , vol.113 , pp. 418-422
    • Vanderby Jr., R.1    Kohles, S.S.2
  • 23
    • 0031043278 scopus 로고    scopus 로고
    • Mechanical evaluation of cross-link designs in rigid pedicle screw systems
    • Dick JC, Zdeblick TA, Bartel BD, Kunz DN. Mechanical evaluation of cross-link designs in rigid pedicle screw systems. Spine 1997;22:370-375.
    • (1997) Spine , vol.22 , pp. 370-375
    • Dick, J.C.1    Zdeblick, T.A.2    Bartel, B.D.3    Kunz, D.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.