-
1
-
-
33646502118
-
Significance of primary stability for osseointegration of dental implants
-
N Lioubavina-Hack, NP Lang, T Karring Significance of primary stability for osseointegration of dental implants Clin Oral Implants Res 17 2006 244 250
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 244-250
-
-
Lioubavina-Hack, N.1
Lang, N.P.2
Karring, T.3
-
2
-
-
0026084439
-
The excessive loss of Brnemark fixtures in type IV bone: A 5-years analysis
-
RA Jaffin, CL Berman The excessive loss of Brnemark fixtures in type IV bone: A 5-years analysis J Periodontol 62 1991 2 4
-
(1991)
J Periodontol
, vol.62
, pp. 2-4
-
-
Jaffin, R.A.1
Berman, C.L.2
-
3
-
-
70350190006
-
-
Quintessence Hanover Park
-
GA Zarb, T Albrektsson, G Baker, SE Eckert, C Stanford, D Tarnow Osseointegration: on continuing synergies in surgery, prosthodontics, and biomaterials 2008 Quintessence Hanover Park 23 25
-
(2008)
Osseointegration: On Continuing Synergies in Surgery, Prosthodontics, and Biomaterials
, pp. 23-25
-
-
Zarb, G.A.1
Albrektsson, T.2
Baker, G.3
Eckert, S.E.4
Stanford, C.5
Tarnow, D.6
-
4
-
-
7444253441
-
A review of selected dental literature on evidence-based treatment planning for dental implants: Report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics
-
MR Wood, SG Vermilyea A review of selected dental literature on evidence-based treatment planning for dental implants: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics J Prosthet Dent 92 2004 447 462
-
(2004)
J Prosthet Dent
, vol.92
, pp. 447-462
-
-
Wood, M.R.1
Vermilyea, S.G.2
-
5
-
-
33846987597
-
Immediately loaded short implants: Analysis of a case series of 133 implants
-
M Degidi Immediately loaded short implants: analysis of a case series of 133 implants Quintessence Int 38 2007 193 201
-
(2007)
Quintessence Int
, vol.38
, pp. 193-201
-
-
Degidi, M.1
-
6
-
-
0033015145
-
Implant treatment without bone grafting in severely resorbed edentulous maxillae
-
T Mattsson, PA Kondell, GW Gynther, U Fredholm, A Bolin Implant treatment without bone grafting in severely resorbed edentulous maxillae J Oral Maxillofac Surg 57 1999 281 287
-
(1999)
J Oral Maxillofac Surg
, vol.57
, pp. 281-287
-
-
Mattsson, T.1
Kondell, P.A.2
Gynther, G.W.3
Fredholm, U.4
Bolin, A.5
-
8
-
-
0034268950
-
Placement of posterior mandibular and maxillary implants in patients with severe bone deficiency: A clinical report of procedure
-
L Krekmanov Placement of posterior mandibular and maxillary implants in patients with severe bone deficiency: a clinical report of procedure Int J Oral Maxillofac Implants 15 2000 722 730
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 722-730
-
-
Krekmanov, L.1
-
9
-
-
20744434076
-
All-on-4 immediate-function concept with Brnemark System implants for completely edentulous maxillae: A 1-year retrospective clinical study
-
P Maló, B Rangert, M Nobre All-on-4 immediate-function concept with Brnemark System implants for completely edentulous maxillae: a 1-year retrospective clinical study Clin Implant Dent Relat Res 7 Suppl 1 2005 S88 S94
-
(2005)
Clin Implant Dent Relat Res
, vol.7
, Issue.SUPPL. 1
-
-
Maló, P.1
Rangert, B.2
Nobre, M.3
-
10
-
-
43249089398
-
Immediate function with fixed implant-supported maxillary dentures: A 12-month pilot study
-
T Tealdo, M Bevilacqua, F Pera, M Menini, G Ravera, C Drago Immediate function with fixed implant-supported maxillary dentures: A 12-month pilot study J Prosthet Dent 99 2008 351 360
-
(2008)
J Prosthet Dent
, vol.99
, pp. 351-360
-
-
Tealdo, T.1
Bevilacqua, M.2
Pera, F.3
Menini, M.4
Ravera, G.5
Drago, C.6
-
11
-
-
38849180188
-
Osteotome sinus floor elevation and simultaneous placement of implants - A 1-year retrospective study with Astra Tech implants
-
R Fermergrd, P Astrand Osteotome sinus floor elevation and simultaneous placement of implants - a 1-year retrospective study with Astra Tech implants Clin Implant Dent Relat Res 10 2008 62 69
-
(2008)
Clin Implant Dent Relat Res
, vol.10
, pp. 62-69
-
-
Fermergrd, R.1
Astrand, P.2
-
12
-
-
56349101740
-
The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysis
-
L Baggi, I Cappelloni, M Di Girolamo, F Maceri, G Vairo The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis J Prosthet Dent 100 2008 422 431
-
(2008)
J Prosthet Dent
, vol.100
, pp. 422-431
-
-
Baggi, L.1
Cappelloni, I.2
Di Girolamo, M.3
MacEri, F.4
Vairo, G.5
-
13
-
-
58449083652
-
Finite-element analysis of stress in bone adjacent to dental implants
-
JH Rubo, EA Souza Finite-element analysis of stress in bone adjacent to dental implants J Oral Implantol 34 2008 248 255
-
(2008)
J Oral Implantol
, vol.34
, pp. 248-255
-
-
Rubo, J.H.1
Souza, E.A.2
-
14
-
-
67651097834
-
Implant-bone interface stress distribution in immediately loaded implants of different diameters: A three-dimensional finite element analysis
-
X Ding, XH Zhu, SH Liao, XH Zhang, H Chen Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis J Prosthodont 18 2009 393 402
-
(2009)
J Prosthodont
, vol.18
, pp. 393-402
-
-
Ding, X.1
Zhu, X.H.2
Liao, S.H.3
Zhang, X.H.4
Chen, H.5
-
15
-
-
0031612903
-
Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
-
R Stegaroiou, T Sato, H Kusakari, O Miyakawa Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis Int J Oral Maxillofac Implants 13 1998 82 90
-
(1998)
Int J Oral Maxillofac Implants
, vol.13
, pp. 82-90
-
-
Stegaroiou, R.1
Sato, T.2
Kusakari, H.3
Miyakawa, O.4
-
16
-
-
0031061805
-
Influence of bone quality on the stress distribution. An in vitro experiment
-
T Ichigawa, H Kanitani, R Wigianto, N Kawamoto, N Matsumoto Influence of bone quality on the stress distribution. An in vitro experiment Clin Oral Implants Res 8 1997 18 22
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 18-22
-
-
Ichigawa, T.1
Kanitani, H.2
Wigianto, R.3
Kawamoto, N.4
Matsumoto, N.5
-
17
-
-
33748323290
-
Impact of implant length and diameter on survival rates
-
F Renouard, D Nisand Impact of implant length and diameter on survival rates Clin Oral Implants Res 2 2006 35 51
-
(2006)
Clin Oral Implants Res
, vol.2
, pp. 35-51
-
-
Renouard, F.1
Nisand, D.2
-
18
-
-
40849136266
-
Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading
-
CL Lin, JC Wang, LC Ramp, PR Liu Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading Int J Oral Maxillofac Implants 23 2008 57 64
-
(2008)
Int J Oral Maxillofac Implants
, vol.23
, pp. 57-64
-
-
Lin, C.L.1
Wang, J.C.2
Ramp, L.C.3
Liu, P.R.4
-
19
-
-
62649083291
-
Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths
-
M Bevilacqua, T Tealdo, M Menini, F Pera, A Mossolov, C Drago Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths Int J Prosthodont 21 2008 539 542
-
(2008)
Int J Prosthodont
, vol.21
, pp. 539-542
-
-
Bevilacqua, M.1
Tealdo, T.2
Menini, M.3
Pera, F.4
Mossolov, A.5
Drago, C.6
-
20
-
-
0035377329
-
Application of finite element analysis in implant dentistry: A review of the literature
-
JP Geng, KB Tan, GR Liu Application of finite element analysis in implant dentistry: a review of the literature J Prosthet Dent 85 2001 585 598
-
(2001)
J Prosthet Dent
, vol.85
, pp. 585-598
-
-
Geng, J.P.1
Tan, K.B.2
Liu, G.R.3
-
21
-
-
0035653714
-
Overdenture attachment selection and the loading of implant and denture-bearing area. Part I: In vivo verification of stereolithographic model
-
SM Heckmann, W Winter, M Meyer, HP Weber, MG Wichmann Overdenture attachment selection and the loading of implant and denture-bearing area. Part I: In vivo verification of stereolithographic model Clin Oral Implants Res 12 2001 617 623
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 617-623
-
-
Heckmann, S.M.1
Winter, W.2
Meyer, M.3
Weber, H.P.4
Wichmann, M.G.5
-
22
-
-
0035653643
-
Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment
-
SM Heckmann, W Winter, M Meyer, HP Weber, MG Wichmann Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment Clin Oral Implants Res 12 2001 640 647
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 640-647
-
-
Heckmann, S.M.1
Winter, W.2
Meyer, M.3
Weber, H.P.4
Wichmann, M.G.5
-
23
-
-
34347372016
-
Tilting of splinted implants for improved prosthodontic support: A two-dimensional finite element analysis
-
A Zampelis, B Rangert, L Heijl Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis J Prosthet Dent 97 6 Suppl 2007 S35 S43
-
(2007)
J Prosthet Dent
, vol.97
, Issue.6 SUPPL.
-
-
Zampelis, A.1
Rangert, B.2
Heijl, L.3
-
24
-
-
77953793328
-
Finite element analysis of stress on dental implant prosthesis
-
JH Rubo, EA Capello Souza Finite element analysis of stress on dental implant prosthesis Clin Implant Dent Relat Res 12 2010 105 113
-
(2010)
Clin Implant Dent Relat Res
, vol.12
, pp. 105-113
-
-
Rubo, J.H.1
Capello Souza, E.A.2
-
25
-
-
0020711801
-
Three-dimensional stress distribution around a dental implant at different stages of interface development
-
L Borchers, P Reichart Three-dimensional stress distribution around a dental implant at different stages of interface development J Dent Res 62 1983 155 159
-
(1983)
J Dent Res
, vol.62
, pp. 155-159
-
-
Borchers, L.1
Reichart, P.2
-
26
-
-
0010485406
-
Functional response
-
P.I. Brnemark G.A. Zarb T. Albrektsson Quintessence Chicago
-
GE Carlsson, T Haraldsson Functional response PI Brnemark GA Zarb T Albrektsson Tissue-integrated prostheses 1985 Quintessence Chicago 155 163
-
(1985)
Tissue-integrated Prostheses
, pp. 155-163
-
-
Carlsson, G.E.1
Haraldsson, T.2
|