메뉴 건너뛰기




Volumn 67, Issue 6, 2010, Pages 1692-1702

Critical influence of framing coil orientation on intra-aneurysmal and neck region hemodynamics in a sidewall aneurysm model

Author keywords

Cerebral aneurysm; Coil embolization; Computer simulation; Hemodynamics

Indexed keywords

ARTICLE; BLOOD VISCOSITY; COIL EMBOLIZATION; COMPUTATIONAL FLUID DYNAMICS; FRAMING COIL ORIENTATION; HEMODYNAMICS; HUMAN; INTRACRANIAL ANEURYSM; LAMINAR FLOW; NECK; PRIORITY JOURNAL; PULSATILE FLOW; SHEAR STRESS; SIDEWALL ANEURYSM; SIMULATION;

EID: 78650517648     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/NEU.0b013e3181f9a93b     Document Type: Article
Times cited : (47)

References (32)
  • 1
    • 0031913870 scopus 로고    scopus 로고
    • Intracranial berry aneurysms: Angiographic and clinical results after endovascular treatment
    • Feb
    • Cognard C, Weill A, Castaings L, Rey A, Moret J. Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology. Feb 1998;206(2):499-510.
    • (1998) Radiology , vol.206 , Issue.2 , pp. 499-510
    • Cognard, C.1    Weill, A.2    Castaings, L.3    Rey, A.4    Moret, J.5
  • 2
    • 0032768267 scopus 로고    scopus 로고
    • Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    • Aug
    • Cognard C, Weill A, Spelle L, et al. Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology. Aug 1999;212(2):348-356.
    • (1999) Radiology , vol.212 , Issue.2 , pp. 348-356
    • Cognard, C.1    Weill, A.2    Spelle, L.3
  • 3
    • 0032471547 scopus 로고    scopus 로고
    • Subarachnoid hemorrhage due to late recurrence of a previously unruptured aneurysm after complete endovascular occlusion
    • Nov-Dec
    • Hodgson TJ, Carroll T, Jellinek DA. Subarachnoid hemorrhage due to late recurrence of a previously unruptured aneurysm after complete endovascular occlusion. AJNR Am J Neuroradiol. Nov-Dec 1998;19(10):1939-1941.
    • (1998) AJNR Am J Neuroradiol , vol.19 , Issue.10 , pp. 1939-1941
    • Hodgson, T.J.1    Carroll, T.2    Jellinek, D.A.3
  • 4
    • 0033969129 scopus 로고    scopus 로고
    • Early aneurysm recurrence after technically satisfactory Guglielmi detachable coil therapy: Is early surveillance needed Case report
    • Feb
    • Makoui AS, Smith DA, Evans AJ, Cahill DW. Early aneurysm recurrence after technically satisfactory Guglielmi detachable coil therapy: is early surveillance needed Case report. J Neurosurg. Feb 2000;92(2):355-358.
    • (2000) J Neurosurg , vol.92 , Issue.2 , pp. 355-358
    • Makoui, A.S.1    Smith, D.A.2    Evans, A.J.3    Cahill, D.W.4
  • 5
    • 0030748591 scopus 로고    scopus 로고
    • Intracranial aneurysms treated with the Guglielmi detachable coil: Midterm clinical results in a consecutive series of 100 patients
    • Aug
    • Malisch TW, Guglielmi G, Vinuela F, et al. Intracranial aneurysms treated with the Guglielmi detachable coil: midterm clinical results in a consecutive series of 100 patients. J Neurosurg. Aug 1997;87(2):176-183.
    • (1997) J Neurosurg , vol.87 , Issue.2 , pp. 176-183
    • Malisch, T.W.1    Guglielmi, G.2    Vinuela, F.3
  • 6
    • 0031841365 scopus 로고    scopus 로고
    • Rerupture of coilembolized aneurysm during long-term observation. Case report
    • Jun
    • Manabe H, Fujita S, Hatayama T, Suzuki S, Yagihashi S. Rerupture of coilembolized aneurysm during long-term observation. Case report. J Neurosurg. Jun 1998;88(6):1096-1098.
    • (1998) J Neurosurg , vol.88 , Issue.6 , pp. 1096-1098
    • Manabe, H.1    Fujita, S.2    Hatayama, T.3    Suzuki, S.4    Yagihashi, S.5
  • 7
    • 0031803824 scopus 로고    scopus 로고
    • Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. Case report
    • Jul
    • Mericle RA, Wakhloo AK, Lopes DK, Lanzino G, Guterman LR, Hopkins LN. Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. Case report. J Neurosurg. Jul 1998;89(1):142-145.
    • (1998) J Neurosurg , vol.89 , Issue.1 , pp. 142-145
    • Mericle, R.A.1    Wakhloo, A.K.2    Lopes, D.K.3    Lanzino, G.4    Guterman, L.R.5    Hopkins, L.N.6
  • 8
    • 38149104803 scopus 로고    scopus 로고
    • Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: The Cerebral Aneurysm Rerupture after Treatment (CARAT) study
    • Jan
    • Johnston SC, Dowd CF, Higashida RT, Lawton MT, Duckwiler GR, Gress DR. Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study. Stroke. Jan 2008;39(1):120-125.
    • (2008) Stroke , vol.39 , Issue.1 , pp. 120-125
    • Johnston, S.C.1    Dowd, C.F.2    Higashida, R.T.3    Lawton, M.T.4    Duckwiler, G.R.5    Gress, D.R.6
  • 9
    • 47649093457 scopus 로고    scopus 로고
    • Coiling and aneurysm rerupture: Incomplete treatment is a causal intermediate not a confounder
    • Jul author reply e122
    • O'Kelly C, Macdonald RL. Coiling and aneurysm rerupture: incomplete treatment is a causal intermediate not a confounder. Stroke. Jul 2008;39(7):e121; author reply e122.
    • (2008) Stroke , vol.39 , Issue.7
    • O'Kelly, C.1    MacDonald, R.L.2
  • 10
    • 0036094962 scopus 로고    scopus 로고
    • Evaluation of the stability of aneurysms after embolization using detachable coils: Correlation between stability of aneurysms and embolized volume of aneurysms
    • May
    • Tamatani S, Ito Y, Abe H, Koike T, Takeuchi S, Tanaka R. Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol. May 2002;23(5):762-767.
    • (2002) AJNR Am J Neuroradiol , vol.23 , Issue.5 , pp. 762-767
    • Tamatani, S.1    Ito, Y.2    Abe, H.3    Koike, T.4    Takeuchi, S.5    Tanaka, R.6
  • 11
    • 0028831266 scopus 로고
    • In vitro study of haemodynamics in a giant saccular aneurysm model: Influence of flow dynamics in the parent vessel and effects of coil embolisation
    • Feb
    • Strother CM. In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation. Neuroradiology. Feb 1995;37(2):159-161.
    • (1995) Neuroradiology , vol.37 , Issue.2 , pp. 159-161
    • Strother, C.M.1
  • 12
    • 2942670789 scopus 로고    scopus 로고
    • Hemodynamic versus hydrodynamic effects of Guglielmi detachable coils on intra-aneurysmal pressure and flow at varying pulse rate and systemic pressure
    • Jun-Jul
    • Sorteberg A, Sorteberg W, Aagaard BD, Rappe A, Strother CM. Hemodynamic versus hydrodynamic effects of Guglielmi detachable coils on intra-aneurysmal pressure and flow at varying pulse rate and systemic pressure. AJNR Am J Neuroradiol. Jun-Jul 2004;25(6):1049-1057.
    • (2004) AJNR Am J Neuroradiol , vol.25 , Issue.6 , pp. 1049-1057
    • Sorteberg, A.1    Sorteberg, W.2    Aagaard, B.D.3    Rappe, A.4    Strother, C.M.5
  • 13
    • 0035052532 scopus 로고    scopus 로고
    • Analysis of slipstream flow in a wide-necked basilar artery aneurysm: Evaluation of potential treatment regimens
    • Apr
    • Imbesi SG, Kerber CW. Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens. AJNR Am J Neuroradiol. Apr 2001;22(4):721-724.
    • (2001) AJNR Am J Neuroradiol , vol.22 , Issue.4 , pp. 721-724
    • Imbesi, S.G.1    Kerber, C.W.2
  • 14
    • 0035213047 scopus 로고    scopus 로고
    • Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm
    • Dec
    • Groden C, Laudan J, Gatchell S, Zeumer H. Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm. J Cereb Blood Flow Metab. Dec 2001;21(12):1464-1471.
    • (2001) J Cereb Blood Flow Metab , vol.21 , Issue.12 , pp. 1464-1471
    • Groden, C.1    Laudan, J.2    Gatchell, S.3    Zeumer, H.4
  • 15
    • 38549172191 scopus 로고    scopus 로고
    • Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms
    • Dec
    • Cha KS, Balaras E, Lieber BB, Sadasivan C, Wakhloo AK. Modeling the interaction of coils with the local blood flow after coil embolization of intracranial aneurysms. J Biomech Eng. Dec 2007;129(6):873-879.
    • (2007) J Biomech Eng , vol.129 , Issue.6 , pp. 873-879
    • Cha, K.S.1    Balaras, E.2    Lieber, B.B.3    Sadasivan, C.4    Wakhloo, A.K.5
  • 16
    • 44449176037 scopus 로고    scopus 로고
    • The haemodynamics of endovascular aneurysm treatment: A computational modelling approach for estimating the influence of multiple coil deployment
    • Jun
    • Kakalis NM, Mitsos AP, Byrne JV, Ventikos Y. The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment. IEEE Trans Med Imaging. Jun 2008;27(6):814-824.
    • (2008) IEEE Trans Med Imaging , vol.27 , Issue.6 , pp. 814-824
    • Kakalis, N.M.1    Mitsos, A.P.2    Byrne, J.V.3    Ventikos, Y.4
  • 17
    • 64849104371 scopus 로고    scopus 로고
    • Estimation of wall shear stress dynamic fluctuations in intracranial atherosclerotic lesions using computational fluid dynamics
    • Aug discussion 334-325
    • Schirmer CM, Malek AM. Estimation of wall shear stress dynamic fluctuations in intracranial atherosclerotic lesions using computational fluid dynamics. Neurosurgery. Aug 2008;63(2):326-334; discussion 334-325.
    • (2008) Neurosurgery , vol.63 , Issue.2 , pp. 326-334
    • Schirmer, C.M.1    Malek, A.M.2
  • 18
    • 55249091059 scopus 로고
    • Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known
    • Mar 28
    • Womersley JR. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known. J Physiol. Mar 28 1955;127(3):553-563.
    • (1955) J Physiol , vol.127 , Issue.3 , pp. 553-563
    • Womersley, J.R.1
  • 19
    • 35948930608 scopus 로고    scopus 로고
    • Prediction of Complex Flow Patterns in Intracranial Atherosclerotic Disease Using Computational Fluid Dynamics
    • Schirmer CM, Malek AM. Prediction of Complex Flow Patterns in Intracranial Atherosclerotic Disease Using Computational Fluid Dynamics. Neurosurgery. 2007;61(4):842-852.
    • (2007) Neurosurgery , vol.61 , Issue.4 , pp. 842-852
    • Schirmer, C.M.1    Malek, A.M.2
  • 20
    • 35948935255 scopus 로고    scopus 로고
    • Wall shear stress gradient analysis within an idealized stenosis using non-newtonian flow
    • Schirmer CM, Malek AM. Wall Shear Stress Gradient Analysis Within An Idealized Stenosis Using Non-Newtonian Flow. Neurosurgery. 2007;61(4):853-864.
    • (2007) Neurosurgery , vol.61 , Issue.4 , pp. 853-864
    • Schirmer, C.M.1    Malek, A.M.2
  • 21
    • 28244482199 scopus 로고    scopus 로고
    • Fluent Lebanon, NH: Fluent Inc
    • Fluent. FLUENT 6.2 User's Guide. Lebanon, NH: Fluent Inc.; 2005.
    • (2005) FLUENT 6.2 User's Guide
  • 22
    • 0015890719 scopus 로고
    • Frequency and shear rate dependence of viscoelasticity of human blood
    • Sep
    • Thurston GB. Frequency and shear rate dependence of viscoelasticity of human blood. Biorheology. Sep 1973;10(3):375-381.
    • (1973) Biorheology , vol.10 , Issue.3 , pp. 375-381
    • Thurston, G.B.1
  • 23
    • 0018610704 scopus 로고
    • Rheological parameters for the viscosity viscoelasticity and thixotropy of blood
    • Thurston GB. Rheological parameters for the viscosity viscoelasticity and thixotropy of blood. Biorheology. 1979;16(3):149-162.
    • (1979) Biorheology , vol.16 , Issue.3 , pp. 149-162
    • Thurston, G.B.1
  • 24
    • 20044391646 scopus 로고    scopus 로고
    • Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries
    • Aug
    • Ford MD, Alperin N, Lee SH, Holdsworth DW, Steinman DA. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas. Aug 2005;26(4):477-488.
    • (2005) Physiol Meas , vol.26 , Issue.4 , pp. 477-488
    • Ford, M.D.1    Alperin, N.2    Lee, S.H.3    Holdsworth, D.W.4    Steinman, D.A.5
  • 25
    • 34249823676 scopus 로고    scopus 로고
    • Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation
    • Jun
    • Meng H, Wang Z, Hoi Y, et al. Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation. Stroke. Jun 2007;38(6):1924-1931.
    • (2007) Stroke , vol.38 , Issue.6 , pp. 1924-1931
    • Meng, H.1    Wang, Z.2    Hoi, Y.3
  • 26
    • 41149156492 scopus 로고    scopus 로고
    • Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: Technical note
    • Apr
    • Mitsos AP, Kakalis NM, Ventikos YP, Byrne JV. Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model: technical note. Neuroradiology. Apr 2008;50(4):341-347.
    • (2008) Neuroradiology , vol.50 , Issue.4 , pp. 341-347
    • Mitsos, A.P.1    Kakalis, N.M.2    Ventikos, Y.P.3    Byrne, J.V.4
  • 27
    • 7644241840 scopus 로고    scopus 로고
    • Magnitude and role of wall shear stress on cerebral aneurysm: Computational fluid dynamic study of 20 middle cerebral artery aneurysms
    • Nov
    • ShojimaM, Oshima M, Takagi K, et al. Magnitude and role of wall shear stress on cerebral aneurysm: computational fluid dynamic study of 20 middle cerebral artery aneurysms. Stroke. Nov 2004;35(11):2500-2505.
    • (2004) Stroke , vol.35 , Issue.11 , pp. 2500-2505
    • Shojima, M.1    Oshima, M.2    Takagi, K.3
  • 28
    • 37649009628 scopus 로고    scopus 로고
    • Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm
    • Dec discussion 1312-1303
    • KimM, Levy EI,Meng H, Hopkins LN. Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm. Neurosurgery. Dec 2007;61(6):1305-1312; discussion 1312-1303.
    • (2007) Neurosurgery , vol.61 , Issue.6 , pp. 1305-1312
    • Kim, M.1    Levy, E.I.2    Meng, H.3    Hopkins, L.N.4
  • 29
    • 34548189435 scopus 로고    scopus 로고
    • Packing performance of helical Guglielmi detachable coil (GDC) 18 in intracranial aneurysms: A comparison with helical GDC 10 coils and complex Trufill/Orbit coils
    • Aug
    • Sluzewski M, van Rooij WJ. Packing performance of helical Guglielmi detachable coil (GDC) 18 in intracranial aneurysms: a comparison with helical GDC 10 coils and complex Trufill/Orbit coils. AJNR Am J Neuroradiol. Aug 2007;28(7):1384-1387.
    • (2007) AJNR Am J Neuroradiol , vol.28 , Issue.7 , pp. 1384-1387
    • Sluzewski, M.1    Van Rooij, W.J.2
  • 30
    • 34548147902 scopus 로고    scopus 로고
    • Complex-shaped platinum coils for brain aneurysms: Higher packing density, improved biomechanical stability, and midterm angiographic outcome
    • Aug
    • Wakhloo AK, Gounis MJ, Sandhu JS, Akkawi N, Schenck AE, Linfante I. Complex-shaped platinum coils for brain aneurysms: higher packing density, improved biomechanical stability, and midterm angiographic outcome. AJNR Am J Neuroradiol. Aug 2007;28(7):1395-1400.
    • (2007) AJNR Am J Neuroradiol , vol.28 , Issue.7 , pp. 1395-1400
    • Wakhloo, A.K.1    Gounis, M.J.2    Sandhu, J.S.3    Akkawi, N.4    Schenck, A.E.5    Linfante, I.6
  • 31
    • 0032471347 scopus 로고    scopus 로고
    • Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: A multivariate analysis
    • Oct
    • Turjman F, Massoud TF, Sayre J, Vinuela F. Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: a multivariate analysis. AJNR Am J Neuroradiol. Oct 1998;19(9):1645- 1651.
    • (1998) AJNR Am J Neuroradiol , vol.19 , Issue.9 , pp. 1645-1651
    • Turjman, F.1    Massoud, T.F.2    Sayre, J.3    Vinuela, F.4
  • 32
    • 0343090363 scopus 로고    scopus 로고
    • Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization
    • Mar
    • Hope JK, Byrne JV, Molyneux AJ. Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR Am J Neuroradiol. Mar 1999;20(3):391-399.
    • (1999) AJNR Am J Neuroradiol , vol.20 , Issue.3 , pp. 391-399
    • Hope, J.K.1    Byrne, J.V.2    Molyneux, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.