메뉴 건너뛰기




Volumn 28, Issue 7, 2007, Pages 1395-1400

Complex-shaped platinum coils for brain aneurysms: Higher packing density, improved biomechanical stability, and midterm angiographic outcome

Author keywords

[No Author keywords available]

Indexed keywords

PLATINUM;

EID: 34548147902     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A0542     Document Type: Article
Times cited : (75)

References (39)
  • 1
    • 0026331291 scopus 로고
    • Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results
    • Guglielmi G, Viñuela F, Sepetka I, et al. Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technique, and experimental results. J Neurosurg 1991;75:1-7
    • (1991) J Neurosurg , vol.75 , pp. 1-7
    • Guglielmi, G.1    Viñuela, F.2    Sepetka, I.3
  • 2
    • 0037404506 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience
    • Murayama Y, Nien YL, Duckwiler G, et al. Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience. J Neurosurg 2003;98:959-66
    • (2003) J Neurosurg , vol.98 , pp. 959-966
    • Murayama, Y.1    Nien, Y.L.2    Duckwiler, G.3
  • 3
    • 2142758066 scopus 로고    scopus 로고
    • Treatment of unruptured aneurysms with GDCs: Clinical experience with 247 aneurysms
    • Gonzalez N, Murayama Y, Nien YL, et al. Treatment of unruptured aneurysms with GDCs: clinical experience with 247 aneurysms. AJNR Am J Neuroradiol 2004;25:577-83
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 577-583
    • Gonzalez, N.1    Murayama, Y.2    Nien, Y.L.3
  • 4
    • 26944466840 scopus 로고    scopus 로고
    • International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion
    • Molyneux AJ, Kerr RS, Yu LM, et al. International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 2005;366:809-17
    • (2005) Lancet , vol.366 , pp. 809-817
    • Molyneux, A.J.1    Kerr, R.S.2    Yu, L.M.3
  • 5
    • 0032506614 scopus 로고    scopus 로고
    • Unruptured intracranial aneurysms - risk of rupture and risks of surgical intervention
    • The International Study of Unruptured Intracranial Aneurysms Investigators
    • The International Study of Unruptured Intracranial Aneurysms Investigators. Unruptured intracranial aneurysms - risk of rupture and risks of surgical intervention. N Engl J Med 1998;339:1725-33
    • (1998) N Engl J Med , vol.339 , pp. 1725-1733
  • 6
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients
    • Viñuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475-82
    • (1997) J Neurosurg , vol.86 , pp. 475-482
    • Viñuela, F.1    Duckwiler, G.2    Mawad, M.3
  • 7
    • 0032768267 scopus 로고    scopus 로고
    • Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    • Cognard C, Weill A, Spelle L, et al. Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 1999;212:348-56
    • (1999) Radiology , vol.212 , pp. 348-356
    • Cognard, C.1    Weill, A.2    Spelle, L.3
  • 8
    • 0038287734 scopus 로고    scopus 로고
    • Endovascular treatment of ruptured intracranial aneurysms with detachable coils: Long term clinical and serial angiographic results
    • Sluzewski M, van Rooij WJ, Rinkel GJ, et al. Endovascular treatment of ruptured intracranial aneurysms with detachable coils: long term clinical and serial angiographic results. Radiology 2003;227:720-24
    • (2003) Radiology , vol.227 , pp. 720-724
    • Sluzewski, M.1    van Rooij, W.J.2    Rinkel, G.J.3
  • 9
    • 24344475289 scopus 로고    scopus 로고
    • Endovascular treatment of posterior circulation aneurysms by using Guglielmi detachable coils: A 10-year single-center experience with special regard to technical development
    • Mordasini P, Schroth G, Guzman R, et al. Endovascular treatment of posterior circulation aneurysms by using Guglielmi detachable coils: a 10-year single-center experience with special regard to technical development. AJNR Am J Neuroradiol 2005;26:1732-38
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 1732-1738
    • Mordasini, P.1    Schroth, G.2    Guzman, R.3
  • 10
    • 33747592391 scopus 로고    scopus 로고
    • Initial clinical experience with a new complex-shaped detachable coil system for the treatment of intracranial cerebral aneurysms
    • Higashida RT, Cognard C, Bracard S. Initial clinical experience with a new complex-shaped detachable coil system for the treatment of intracranial cerebral aneurysms. Intervent Neuroradiol 2006;12:123-30
    • (2006) Intervent Neuroradiol , vol.12 , pp. 123-130
    • Higashida, R.T.1    Cognard, C.2    Bracard, S.3
  • 11
    • 0041471638 scopus 로고    scopus 로고
    • Increasing the packing of small aneurysms with complex-shaped coils: An in vitro study
    • Piotin M, Iijima A, Wada H, et al. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study. AJNR Am J Neuroradiol 2003;24:1446-48
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1446-1448
    • Piotin, M.1    Iijima, A.2    Wada, H.3
  • 12
    • 27144550968 scopus 로고    scopus 로고
    • Coil thickness and packing of cerebral aneurysms: A comparative study of two types of coils
    • Slob MJ, van Rooij WJ, Sluzewski M. Coil thickness and packing of cerebral aneurysms: a comparative study of two types of coils. AJNR Am J Neuroradiol 2005;26:901-03
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 901-903
    • Slob, M.J.1    van Rooij, W.J.2    Sluzewski, M.3
  • 13
    • 32944456521 scopus 로고    scopus 로고
    • Three-dimensional packing with complex Orbit coils for the endovascular treatment of intracranial aneurysms
    • Lubicz B, Leclerc X, Gauvrit JY, et al. Three-dimensional packing with complex Orbit coils for the endovascular treatment of intracranial aneurysms. AJNR Am J Neuroradiol 2005;26:1342-48
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 1342-1348
    • Lubicz, B.1    Leclerc, X.2    Gauvrit, J.Y.3
  • 14
    • 0038275794 scopus 로고    scopus 로고
    • Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter
    • Baldi S, Mounayer C, Piotin M, et al. Balloon-assisted coil placement in wide-neck bifurcation aneurysms by use of a new, compliant balloon microcatheter. AJNR Am J Neuroradiol 2003;24:1222-25
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1222-1225
    • Baldi, S.1    Mounayer, C.2    Piotin, M.3
  • 15
    • 0036094962 scopus 로고    scopus 로고
    • Evaluation of the stability of aneurysms using detachable coils: Correlation between stability of aneurysms and embolized volume of aneurysms
    • Tamatani S, Ito Y, Abe H, et al. Evaluation of the stability of aneurysms using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol 2002;23:762-67
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 762-767
    • Tamatani, S.1    Ito, Y.2    Abe, H.3
  • 16
    • 0038652187 scopus 로고    scopus 로고
    • Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils
    • Raymond J, Guilbert F, Weill A, et al. Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 2003;34:1398-403
    • (2003) Stroke , vol.34 , pp. 1398-1403
    • Raymond, J.1    Guilbert, F.2    Weill, A.3
  • 17
    • 0032471347 scopus 로고    scopus 로고
    • Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: A multivariate analysis
    • Turjman F, Massoud TF, Sayre J, et al. Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: a multivariate analysis. AJNR Am J Neuroradiol 1998;19:1645-51
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 1645-1651
    • Turjman, F.1    Massoud, T.F.2    Sayre, J.3
  • 18
    • 0033366775 scopus 로고    scopus 로고
    • Long-term histopathologic findings in two cerebral aneurysms embolized with Guglielmi detachable coils
    • Castro E, Fortea F, Villoria F, et al. Long-term histopathologic findings in two cerebral aneurysms embolized with Guglielmi detachable coils. AJNR Am J Neuroradiol 1999;20:549-52
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 549-552
    • Castro, E.1    Fortea, F.2    Villoria, F.3
  • 19
    • 0030964914 scopus 로고    scopus 로고
    • Scanning electron microscopic findings in a basilar tip aneurysm embolized with Guglielmi detachable coils
    • Horowitz MB, Purdy PD, Burns D, et al. Scanning electron microscopic findings in a basilar tip aneurysm embolized with Guglielmi detachable coils. AJNR Am J Neuroradiol 1997;18:688-90
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 688-690
    • Horowitz, M.B.1    Purdy, P.D.2    Burns, D.3
  • 20
    • 0029069722 scopus 로고
    • Histological findings in giant aneurysms treated with Guglielmi detachable coils: Report of two cases with autopsy correlation
    • Molyneux AJ, Ellison DW, Morris J, et al. Histological findings in giant aneurysms treated with Guglielmi detachable coils: report of two cases with autopsy correlation. J Neurosurg 1995;83:129-32
    • (1995) J Neurosurg , vol.83 , pp. 129-132
    • Molyneux, A.J.1    Ellison, D.W.2    Morris, J.3
  • 21
    • 0031014129 scopus 로고    scopus 로고
    • Long-term angiographic and histopathologic findings in experimental aneurysms of the carotid bifurcation embolized with platinum and tungsten coils
    • Reul J, Weis J, Spetzger U, et al. Long-term angiographic and histopathologic findings in experimental aneurysms of the carotid bifurcation embolized with platinum and tungsten coils. AJNR Am J Neuroradiol 1997;18:35-42
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 35-42
    • Reul, J.1    Weis, J.2    Spetzger, U.3
  • 22
    • 0028895392 scopus 로고
    • Long-term histopathologic changes in canine aneurysms embolized with Guglielmi detachable coils
    • Mawad ME, Mawad JK, Cartwright J Jr, et al. Long-term histopathologic changes in canine aneurysms embolized with Guglielmi detachable coils. AJNR Am J Neuroradiol 1995;16:7-13
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 7-13
    • Mawad, M.E.1    Mawad, J.K.2    Cartwright Jr, J.3
  • 23
    • 0032887656 scopus 로고    scopus 로고
    • Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits
    • Kallmes DF, Helm GA, Hudson SB, et al. Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits. Radiology 1999;213:217-22
    • (1999) Radiology , vol.213 , pp. 217-222
    • Kallmes, D.F.1    Helm, G.A.2    Hudson, S.B.3
  • 24
    • 0037326691 scopus 로고    scopus 로고
    • Coiling of very large or giant cerebral aneurysms: Long-term clinical and serial angiographic results
    • Sluzewski M, Menovsky T, van Rooij WJ, et al. Coiling of very large or giant cerebral aneurysms: long-term clinical and serial angiographic results. AJNR Am J Neuroradiol 2003;24:257-62
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 257-262
    • Sluzewski, M.1    Menovsky, T.2    van Rooij, W.J.3
  • 25
    • 30144442227 scopus 로고    scopus 로고
    • Durability of aneurysm embolization with Matrix detachable coils
    • Fiorella D, Albuquerque FC, McDougall CG. Durability of aneurysm embolization with Matrix detachable coils. Neurosurgery 2006;58:51-59
    • (2006) Neurosurgery , vol.58 , pp. 51-59
    • Fiorella, D.1    Albuquerque, F.C.2    McDougall, C.G.3
  • 26
    • 33645821026 scopus 로고    scopus 로고
    • Endosaccular treatment of intracranial aneurysms using Matrix coils
    • Niimi Y, Song J, Madrid M, et al. Endosaccular treatment of intracranial aneurysms using Matrix coils. Stroke 2006;37:1028-32
    • (2006) Stroke , vol.37 , pp. 1028-1032
    • Niimi, Y.1    Song, J.2    Madrid, M.3
  • 27
    • 24644475819 scopus 로고    scopus 로고
    • Polyglycolide/polylactide- coated platinum coils for patients with ruptured and unruptured cerebral aneurysms: A single-center experience
    • Linfante I, Akkawi NM, Perlow A, et al. Polyglycolide/polylactide- coated platinum coils for patients with ruptured and unruptured cerebral aneurysms: a single-center experience. Stroke 2005;36:1948-53
    • (2005) Stroke , vol.36 , pp. 1948-1953
    • Linfante, I.1    Akkawi, N.M.2    Perlow, A.3
  • 28
    • 33645749294 scopus 로고    scopus 로고
    • HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: Periprocedural results
    • Cloft HJ. HydroCoil for Endovascular Aneurysm Occlusion (HEAL) study: periprocedural results. AJNR Am J Neuroradiol 2006;27:289-92
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 289-292
    • Cloft, H.J.1
  • 29
    • 10744233084 scopus 로고    scopus 로고
    • Endovascular coil occlusion of 1811 intracranial aneurysms: Early angiographic and clinical results
    • Henkes H, Fischer S, Weber W, et al. Endovascular coil occlusion of 1811 intracranial aneurysms: early angiographic and clinical results. Neurosurgery 2004;54:268-85
    • (2004) Neurosurgery , vol.54 , pp. 268-285
    • Henkes, H.1    Fischer, S.2    Weber, W.3
  • 30
    • 27144448992 scopus 로고    scopus 로고
    • Influence of coil thickness on packing, re-opening and retreatment of intracranial aneurysms: A comparative study of two types of coils
    • Slob MJ, van Rooij WJ, Sluzewski M. Influence of coil thickness on packing, re-opening and retreatment of intracranial aneurysms: a comparative study of two types of coils. Neurol Res 2005;27:S116-19
    • (2005) Neurol Res , vol.27
    • Slob, M.J.1    van Rooij, W.J.2    Sluzewski, M.3
  • 31
    • 0035018234 scopus 로고    scopus 로고
    • Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: Correlation between coil packing density and coil compaction
    • Kawanabe Y, Sadato A, Taki W, et al. Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction. Acta Neurochir (Wien) 2001;143:451-55
    • (2001) Acta Neurochir (Wien) , vol.143 , pp. 451-455
    • Kawanabe, Y.1    Sadato, A.2    Taki, W.3
  • 32
    • 2442640381 scopus 로고    scopus 로고
    • Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils
    • Sluzewski M, van Rooij WJ, Slob M, et al. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology 2004;231:653-58
    • (2004) Radiology , vol.231 , pp. 653-658
    • Sluzewski, M.1    van Rooij, W.J.2    Slob, M.3
  • 33
    • 0033797323 scopus 로고    scopus 로고
    • Topic review: Surface modifications enhancing biological activity of Guglielmi detachable coils in treating intracranial aneurysms
    • Abrahams JM, Diamond SL, Hurst RW, et al. Topic review: surface modifications enhancing biological activity of Guglielmi detachable coils in treating intracranial aneurysms. Surg Neurol 2000;54:34-40
    • (2000) Surg Neurol , vol.54 , pp. 34-40
    • Abrahams, J.M.1    Diamond, S.L.2    Hurst, R.W.3
  • 34
    • 0034528922 scopus 로고    scopus 로고
    • Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils
    • Uchiyama N, Kida S, Nomura M, et al. Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils. Intervent Neuroradiol 2000;6(suppl 1):59-63
    • (2000) Intervent Neuroradiol , vol.6 , Issue.SUPPL. 1 , pp. 59-63
    • Uchiyama, N.1    Kida, S.2    Nomura, M.3
  • 35
    • 4744352163 scopus 로고    scopus 로고
    • Remodeling of saccular cerebral artery aneurysm wall is associated with rupture: Histological analysis of 24 unruptured and 42 ruptured cases
    • Frosen J, Piippo A, Paetau A, et al. Remodeling of saccular cerebral artery aneurysm wall is associated with rupture: histological analysis of 24 unruptured and 42 ruptured cases. Stroke 2004;35:2287-93
    • (2004) Stroke , vol.35 , pp. 2287-2293
    • Frosen, J.1    Piippo, A.2    Paetau, A.3
  • 36
    • 33748063638 scopus 로고    scopus 로고
    • Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms
    • Piotin M, Daghman B, Mounayer C, et al. Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am J Neuroradiol 2006;27:839-42
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 839-842
    • Piotin, M.1    Daghman, B.2    Mounayer, C.3
  • 37
    • 33644844173 scopus 로고    scopus 로고
    • Volume measurement of intracranial aneurysms from 3D rotational angiography: Improvement of accuracy by gradient edge detection
    • Bescos JO, Slob MJ, Slump CH, et al. Volume measurement of intracranial aneurysms from 3D rotational angiography: improvement of accuracy by gradient edge detection. AJNR Am J Neuroradiol 2005;26:2569-72
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2569-2572
    • Bescos, J.O.1    Slob, M.J.2    Slump, C.H.3
  • 38
    • 18744389487 scopus 로고    scopus 로고
    • Endovascular coil embolization of intracranial aneurysms: Important factors related to rates and outcomes of incomplete occlusion
    • Kole MK, Pelz DM, Kalapos P, et al. Endovascular coil embolization of intracranial aneurysms: important factors related to rates and outcomes of incomplete occlusion. J Neurosurg, 2005;102:607-15
    • (2005) J Neurosurg , vol.102 , pp. 607-615
    • Kole, M.K.1    Pelz, D.M.2    Kalapos, P.3
  • 39
    • 16844376267 scopus 로고    scopus 로고
    • Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: Correlation between coil packing ratio and coil compaction
    • Kai Y, Hamada J, Morioka M, et al. Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: correlation between coil packing ratio and coil compaction. Neurosurgery, 2005;56:785-92
    • (2005) Neurosurgery , vol.56 , pp. 785-792
    • Kai, Y.1    Hamada, J.2    Morioka, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.