메뉴 건너뛰기




Volumn 19, Issue 9, 2010, Pages 609-612

IOP variations in the sitting and supine positions

Author keywords

intraocular pressure; non contact tonometry; Pulsair EasyEye; supine position; upright position

Indexed keywords

ADULT; ARTICLE; COMPARATIVE STUDY; FEMALE; HUMAN; INTRAOCULAR PRESSURE; MALE; PRIORITY JOURNAL; SITTING; SUPINE POSITION; TONOMETER;

EID: 78650453627     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e3181ca7ca5     Document Type: Article
Times cited : (24)

References (30)
  • 1
    • 32644481194 scopus 로고    scopus 로고
    • Increase of peak intraocular pressure during sleep in reproduced diurnal changes by posture
    • DOI 10.1001/archopht.124.2.165
    • Hara T, Hara T, Tsuru T. Increase of peak intraocular pressure during sleep in reproduced diurnal changes by posture. Arch Ophthalmol. 2006;124:165-168. (Pubitemid 43247064)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.2 , pp. 165-168
    • Hara, T.1    Hara, T.2    Tsuru, T.3
  • 2
    • 21344437702 scopus 로고    scopus 로고
    • Importance of early morning intraocular pressure recording for measurement of diurnal variation of intraocular pressure [9]
    • DOI 10.1136/bjo.2004.052787
    • Syam PP, Mavrikakis I, Liu C. Importance of early morning intraocular pressure recording for measurement of diurnal variation of intraocular pressure. Br J Ophthalmol. 2005;89: 926-927. (Pubitemid 40904829)
    • (2005) British Journal of Ophthalmology , vol.89 , Issue.7 , pp. 926-927
    • Syam, P.P.1    Mavrikakis, I.2    Liu, C.3
  • 3
    • 0026349823 scopus 로고
    • Diurnal variations in intraocular pressure
    • Wilensky JT. Diurnal variations in intraocular pressure. Trans Am Ophthalmol Soc. 1991;89:757-790.
    • (1991) Trans Am Ophthalmol Soc. , vol.89 , pp. 757-790
    • Wilensky, J.T.1
  • 4
    • 4644281544 scopus 로고    scopus 로고
    • The effect of body inclination during prone positioning on intraocular pressure in awake volunteers: A comparison of two operating tables
    • DOI 10.1213/01.ANE.0000130851.37039.50
    • Ozcan MS, Praetel C, Bhatti MT, et al. The effect of body inclination during prone positioning on intraocular pressure in awake volunteers: A comparison of two operating tables. Anesth Analg. 2004;99:1152-1158; table. (Pubitemid 39287409)
    • (2004) Anesthesia and Analgesia , vol.99 , Issue.4 , pp. 1152-1158
    • Ozcan, M.S.1    Praetel, C.2    Tariq Bhatti, M.3    Gravenstein, N.4    Mahla, M.E.5    Seubert, C.N.6
  • 5
    • 33947230036 scopus 로고    scopus 로고
    • Relationships between 24 hours observations in intraocular pressure versus blood pressure, heart rate, nitric oxide and age in the medical chronobiology aging project
    • Perlman JI, Delany CM, Sothern RB, et al. Relationships between 24 hours observations in intraocular pressure versus blood pressure, heart rate, nitric oxide and age in the medical chronobiology aging project. Clin Ter. 2007;158:31-47.
    • (2007) Clin Ter. , vol.158 , pp. 31-47
    • Perlman, J.I.1    Delany, C.M.2    Sothern, R.B.3
  • 6
    • 0035121613 scopus 로고    scopus 로고
    • Diurnal variation of episcleral venous pressure in healthy patients: A pilot study
    • Blondeau P, Tetrault JP, Papamarkakis C. Diurnal variation of episcleral venous pressure in healthy patients: A pilot study. J Glaucoma. 2001;10:18-24. (Pubitemid 32151790)
    • (2001) Journal of Glaucoma , vol.10 , Issue.1 , pp. 18-24
    • Blondeau, P.1    Tetrault, J.-P.2    Papamarkakis, C.3
  • 9
    • 0242442128 scopus 로고    scopus 로고
    • Effect of Posture on Blood and Intraocular Pressures in Multiple System Atrophy, Pure Autonomic Failure, and Baroreflex Failure
    • DOI 10.1161/01.CIR.0000097114.11038.26
    • Singleton CD, Robertson D, Byrne DW, et al. Effect of posture on blood and intraocular pressures in multiple system atrophy, pure autonomic failure, and baroreflex failure. Circulation. 2003;108:2349-2354. (Pubitemid 37413541)
    • (2003) Circulation , vol.108 , Issue.19 , pp. 2349-2354
    • Singleton, C.D.1    Robertson, D.2    Byrne, D.W.3    Joos, K.M.4
  • 10
    • 0031214581 scopus 로고    scopus 로고
    • Does the change of anterior chamber depth or/and episcleral venous pressure cause intraocular pressure change in postural variation?
    • Lam AK, Douthwaite WA. Does the change of anterior chamber depth or/and episcleral venous pressure cause intraocular pressure change in postural variation?. Optom Vis Sci. 1997;74:664-667.
    • (1997) Optom Vis Sci. , vol.74 , pp. 664-667
    • Lam, A.K.1    Douthwaite, W.A.2
  • 11
    • 79952066034 scopus 로고    scopus 로고
    • Postural response of intraocular pressure and visual field damage in patients with untreated normal-tension glaucoma
    • Doi:10.1097/IJG.0b013e3181a98f30
    • Kiuchi T, Motoyama Y, Oshika T. Postural response of intraocular pressure and visual field damage in patients with untreated normal-tension glaucoma. J Glaucoma. 2009. Doi:10.1097/IJG.0b013e3181a98f30.
    • (2009) J Glaucoma.
    • Kiuchi, T.1    Motoyama, Y.2    Oshika, T.3
  • 12
    • 0027357580 scopus 로고
    • Bedside evaluation of intraocular pressure in critically ill patients, ventilated at different levels of positive end-expiratory pressure
    • Spapen HD, D'Haese J, Diltoer M, et al. Bedside evaluation of intraocular pressure in critically ill patients, ventilated at different levels of positive end-expiratory pressure. Acta Anaesthesiol Belg. 1993;44:39-43.
    • (1993) Acta Anaesthesiol Belg. , vol.44 , pp. 39-43
    • Spapen, H.D.1    D'Haese, J.2    Diltoer, M.3
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: Why plotting difference against standard method is misleading. Lancet. 1995;346:1085-1087.
    • (1995) Lancet. , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 37849047537 scopus 로고    scopus 로고
    • Accuracy and reliability of the Keeler Pulsair EasyEye non-contact tonometer
    • Ogbuehi KC, Almubrad TM. Accuracy and reliability of the Keeler Pulsair EasyEye non-contact tonometer. Optom Vis Sci. 2008;85:61-66.
    • (2008) Optom Vis Sci. , vol.85 , pp. 61-66
    • Ogbuehi, K.C.1    Almubrad, T.M.2
  • 19
    • 60349122575 scopus 로고    scopus 로고
    • A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes
    • Babalola OE, Kehinde AV, Iloegbunam AC, et al. A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes. Ophthalmic Physiol Opt. 2009;29:182-188.
    • (2009) Ophthalmic Physiol Opt. , vol.29 , pp. 182-188
    • Babalola, O.E.1    Kehinde, A.V.2    Iloegbunam, A.C.3
  • 20
    • 33845506427 scopus 로고    scopus 로고
    • Augeninnendruckmessungen im tages- und nachtverlauf bei glaukompatienten und normalprobanden mittels Goldmann- und Perkins-applanationstonometrie
    • DOI 10.1007/s00347-006-1407-7
    • Wozniak K, Koller AU, Sporl E, et al. Intraocular pressure measurement during the day and night for glaucoma patients and normal controls using Goldmann and Perkins applanation tonometry. Ophthalmologe. 2006;103:1027-1031. (Pubitemid 44915476)
    • (2006) Ophthalmologe , vol.103 , Issue.12 , pp. 1027-1031
    • Wozniak, K.1    Koller, A.U.2    Sporl, E.3    Bohm, A.G.4    Pillunat, L.E.5
  • 21
    • 13844266989 scopus 로고    scopus 로고
    • Clinical evaluation of the new TGDc-01 "PRA" palpebral tonometer: Comparison with contact and non-contact tonometry
    • Garcia RC, Giraldez Fernandez MJ, Cervino EA, et al. Clinical evaluation of the new TGDc-01 "PRA" palpebral tonometer: Comparison with contact and non-contact tonometry. Optom Vis Sci. 2005;82:143-150.
    • (2005) Optom Vis Sci. , vol.82 , pp. 143-150
    • Garcia, R.C.1    Giraldez Fernandez, M.J.2    Cervino, E.A.3
  • 22
    • 20444472031 scopus 로고    scopus 로고
    • Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    • DOI 10.1007/s00417-004-0971-2
    • Losch A, Scheuerle A, Rupp V, et al. Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol. 2005;243:313-316. (Pubitemid 40823235)
    • (2005) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.243 , Issue.4 , pp. 313-316
    • Losch, A.1    Scheuerle, A.2    Rupp, V.3    Auffarth, G.4    Becker, M.5
  • 23
    • 21244458331 scopus 로고    scopus 로고
    • The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - A pilot study
    • DOI 10.1111/j.1475-1313.2005.00296.x
    • Lam AK, Lam CH, Chan R. The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry-a pilot study. Ophthalmic Physiol Opt. 2005;25:205-210. (Pubitemid 41702437)
    • (2005) Ophthalmic and Physiological Optics , vol.25 , Issue.3 , pp. 205-210
    • Lam, A.K.C.1    Lam, C.H.2    Chan, R.3
  • 24
    • 34548049291 scopus 로고    scopus 로고
    • Evaluation of the impedance tonometers TGDc-01 and iCare according to the international ocular tonometer standards ISO 8612
    • DOI 10.1007/s00417-006-0483-3
    • Ruokonen PC, Schwenteck T, Draeger J. Evaluation of the impedance tonometers TGDc-01 and iCare according to the international ocular tonometer standards ISO 8612. Graefes Arch Clin Exp Ophthalmol. 2007;245:1259-1265. (Pubitemid 47278661)
    • (2007) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.245 , Issue.9 , pp. 1259-1265
    • Ruokonen, P.C.1    Schwenteck, T.2    Draeger, J.3
  • 25
    • 33745043449 scopus 로고    scopus 로고
    • Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma
    • DOI 10.1001/archopht.124.6.793
    • Barkana Y, Anis S, Liebmann J, et al. Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma. Arch Ophthalmol. 2006;124: 793-797. (Pubitemid 43877672)
    • (2006) Archives of Ophthalmology , vol.124 , Issue.6 , pp. 793-797
    • Barkana, Y.1    Anis, S.2    Liebmann, J.3    Tello, C.4    Ritch, R.5
  • 26
    • 0032870796 scopus 로고    scopus 로고
    • Elevation of human intraocular pressure at night under moderate illumination
    • Liu JH, Kripke DF, Hoffman RE, et al. Elevation of human intraocular pressure at night under moderate illumination. Invest Ophthalmol Vis Sci. 1999;40:2439-2442.
    • (1999) Invest Ophthalmol Vis Sci. , vol.40 , pp. 2439-2442
    • Liu, J.H.1    Kripke, D.F.2    Hoffman, R.E.3
  • 27
    • 0141764856 scopus 로고    scopus 로고
    • Nocturnal elevation of intraocular pressure is detectable in the sitting position
    • Liu JH, Bouligny RP, Kripke DF, et al. Nocturnal elevation of intraocular pressure is detectable in the sitting position. Invest Ophthalmol Vis Sci. 2003;44:4439-4442.
    • (2003) Invest Ophthalmol Vis Sci. , vol.44 , pp. 4439-4442
    • Liu, J.H.1    Bouligny, R.P.2    Kripke, D.F.3
  • 28
    • 4444308745 scopus 로고    scopus 로고
    • Comparison of the nocturnal effects of once-daily timolol and latanoprost on intraocular pressure
    • DOI 10.1016/j.ajo.2004.04.022, PII S0002939404004039
    • Liu JH, Kripke DF, Weinreb RN. Comparison of the nocturnal effects of once-daily timolol and latanoprost on intraocular pressure. Am J Ophthalmol. 2004;138:389-395. (Pubitemid 39208565)
    • (2004) American Journal of Ophthalmology , vol.138 , Issue.3 , pp. 389-395
    • Liu, J.H.K.1    Kripke, D.F.2    Weinreb, R.N.3
  • 29
    • 0032732940 scopus 로고    scopus 로고
    • Twenty-four-hour pattern of intraocular pressure in the aging population
    • Liu JH, Kripke DF, Twa MD, et al. Twenty-four-hour pattern of intraocular pressure in the aging population. Invest Ophthalmol Vis Sci. 1999;40:2912-2917.
    • (1999) Invest Ophthalmol Vis Sci. , vol.40 , pp. 2912-2917
    • Liu, J.H.1    Kripke, D.F.2    Twa, M.D.3
  • 30
    • 35848967549 scopus 로고    scopus 로고
    • Changes in intraocular pressure due to surgical positioning: Studying potential risk for postoperative vision loss
    • Walick KS, Kragh JE Jr, Ward JA, et al. Changes in intraocular pressure due to surgical positioning: Studying potential risk for postoperative vision loss. Spine. 2007;32: 2591-2595.
    • (2007) Spine. , vol.32 , pp. 2591-2595
    • Walick, K.S.1    Kragh Jr., J.E.2    Ward, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.