메뉴 건너뛰기




Volumn 25, Issue 1, 2011, Pages 94-100

Evaluating outcomes of endoleak discrepancies between computed tomography scan and ultrasound imaging after endovascular abdominal aneurysm repair

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM;

EID: 78650423582     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.avsg.2010.08.003     Document Type: Conference Paper
Times cited : (16)

References (17)
  • 1
    • 0033637752 scopus 로고    scopus 로고
    • Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair
    • Y.G. Wolf, B.L. Johnson, B.B. Hill, G.D. Rubin, T.J. Fogarty, and C.K. Zarins Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair J Vasc Surg 32 2000 1142 1148
    • (2000) J Vasc Surg , vol.32 , pp. 1142-1148
    • Wolf, Y.G.1    Johnson, B.L.2    Hill, B.B.3    Rubin, G.D.4    Fogarty, T.J.5    Zarins, C.K.6
  • 2
    • 26944486193 scopus 로고    scopus 로고
    • Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts
    • A.F. AbuRahma, C.A. Welch, B.B. Mullins, and B. Dyer Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts J Endovasc Ther 12 2005 568 573
    • (2005) J Endovasc Ther , vol.12 , pp. 568-573
    • Aburahma, A.F.1    Welch, C.A.2    Mullins, B.B.3    Dyer, B.4
  • 3
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review
    • A. Roy, L.C. Brown, and A. Rodway Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review J Endovasc Ther 12 2005 297 305
    • (2005) J Endovasc Ther , vol.12 , pp. 297-305
    • Roy, A.1    Brown, L.C.2    Rodway, A.3
  • 4
    • 0141885385 scopus 로고    scopus 로고
    • Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair
    • K.G. Raman, N. Missig-Carroll, T. Richardson, S.C. Muluk, and M.S. Makaraoun Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair J Vasc Surg 38 2003 645 651
    • (2003) J Vasc Surg , vol.38 , pp. 645-651
    • Raman, K.G.1    Missig-Carroll, N.2    Richardson, T.3    Muluk, S.C.4    Makaraoun, M.S.5
  • 5
    • 70350475525 scopus 로고    scopus 로고
    • Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for intervention
    • G.C. Schmieder, C.L. Stout, G.K. Stokes, F.N. Parent, and J.M. Panneton Endoleak after endovascular aneurysm repair: duplex ultrasound imaging is better than computed tomography at determining the need for intervention J Vasc Surg 50 2009 1012 1018
    • (2009) J Vasc Surg , vol.50 , pp. 1012-1018
    • Schmieder, G.C.1    Stout, C.L.2    Stokes, G.K.3    Parent, F.N.4    Panneton, J.M.5
  • 6
    • 63049112353 scopus 로고    scopus 로고
    • Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: A safe alternative for stable aneurysms
    • R.A. Chaer, A. Gushchin, R. Rhee, L. Marone, J.S. Cho, and S. Leers Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms J Vasc Surg 49 2009 845 849
    • (2009) J Vasc Surg , vol.49 , pp. 845-849
    • Chaer, R.A.1    Gushchin, A.2    Rhee, R.3    Marone, L.4    Cho, J.S.5    Leers, S.6
  • 7
    • 58549097442 scopus 로고    scopus 로고
    • Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: A comparison with computed tomography aortography
    • B.J. Manning, S.M. O'Neill, S.N. Haider, M.P. Colgan, P. Madhavan, and D.J. Moore Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography J Vasc Surg 49 2009 60 65
    • (2009) J Vasc Surg , vol.49 , pp. 60-65
    • Manning, B.J.1    O'Neill, S.M.2    Haider, S.N.3    Colgan, M.P.4    Madhavan, P.5    Moore, D.J.6
  • 8
    • 35548993746 scopus 로고    scopus 로고
    • Ultrasound surveillance of endovascular aneurysm repair: A safe modality versus computed tomography
    • J.T. Collins, M.J. Boros, and K. Combs Ultrasound surveillance of endovascular aneurysm repair: a safe modality versus computed tomography Ann Vasc Surg 21 2007 671 675
    • (2007) Ann Vasc Surg , vol.21 , pp. 671-675
    • Collins, J.T.1    Boros, M.J.2    Combs, K.3
  • 9
    • 61349121986 scopus 로고    scopus 로고
    • Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair
    • R. Iezzi, R. Basilico, D. Giancristofaro, D. Pascali, A.R. Cotroneo, and M.L. Storto Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair J Vasc Surg 49 2009 552 560
    • (2009) J Vasc Surg , vol.49 , pp. 552-560
    • Iezzi, R.1    Basilico, R.2    Giancristofaro, D.3    Pascali, D.4    Cotroneo, A.R.5    Storto, M.L.6
  • 11
    • 3042697432 scopus 로고    scopus 로고
    • Imaging modalities for the detection and management of endoleaks
    • S.W. Stavropoulos, and R.A. Baum Imaging modalities for the detection and management of endoleaks Semin Vasc Surg 17 2004 154 160
    • (2004) Semin Vasc Surg , vol.17 , pp. 154-160
    • Stavropoulos, S.W.1    Baum, R.A.2
  • 12
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • D.J. Brenner, and E.J. Hall Computed tomography - an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 14
    • 3543036969 scopus 로고    scopus 로고
    • Surveillance after endovascular aneurysm repair: Diagnostics, complications, and associated costs
    • M. Prinssen, C.L. Wixon, E. Buskens, and J.D. Blankensteijn Surveillance after endovascular aneurysm repair: diagnostics, complications, and associated costs Ann Vasc Surg 18 2004 421 427
    • (2004) Ann Vasc Surg , vol.18 , pp. 421-427
    • Prinssen, M.1    Wixon, C.L.2    Buskens, E.3    Blankensteijn, J.D.4
  • 15
    • 70350573366 scopus 로고    scopus 로고
    • Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan
    • B.R. Beeman, L.M. Doctor, K. Doerr, S. McAfee-Bennett, M.J. Dougherty, and K.D. Calligaro Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan J Vasc Surg 50 2009 1019 1024
    • (2009) J Vasc Surg , vol.50 , pp. 1019-1024
    • Beeman, B.R.1    Doctor, L.M.2    Doerr, K.3    McAfee-Bennett, S.4    Dougherty, M.J.5    Calligaro, K.D.6
  • 16
    • 33748864627 scopus 로고    scopus 로고
    • Fate of endoleaks detected by ct angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms
    • A.F. AbuRahma Fate of endoleaks detected by ct angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms J Endovasc Ther 13 2006 490 495
    • (2006) J Endovasc Ther , vol.13 , pp. 490-495
    • Aburahma, A.F.1
  • 17
    • 19044368230 scopus 로고    scopus 로고
    • Nature and significance of endoleaks and endotension: Summary of opinions expressed at an international conference
    • F.J. Veith, R.A. Baum, and T. Ohki Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference J Vasc Surg 35 2002 1029 1035
    • (2002) J Vasc Surg , vol.35 , pp. 1029-1035
    • Veith, F.J.1    Baum, R.A.2    Ohki, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.