메뉴 건너뛰기




Volumn 35, Issue 5, 2002, Pages 1029-1035

Nature and significance of endoleaks and endotension: Summary of opinions expressed at an international conference

Author keywords

[No Author keywords available]

Indexed keywords

AORTA SURGERY; ARTICLE; CARDIOLOGIST; ENDOLEAK; ENDOVASCULAR SURGERY; PRIORITY JOURNAL; RADIOLOGIST; SURGEON; AORTA ANEURYSM; BLOOD VESSEL PROSTHESIS; BLOOD VESSEL TRANSPLANTATION; HEALTH PERSONNEL ATTITUDE; HUMAN; ORGANIZATION; POSTOPERATIVE COMPLICATION; PROSTHESIS FAILURE; REVIEW;

EID: 19044368230     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1067/mva.2002.123095     Document Type: Article
Times cited : (576)

References (26)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysms
    • Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-9.
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-499
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 0030912698 scopus 로고    scopus 로고
    • The EVT tube and bifurcated graft systems: Technical considerations and clinical summary
    • Moore WS. The EVT tube and bifurcated graft systems: technical considerations and clinical summary. J Endovasc Surg 1997;4:182-94.
    • (1997) J Endovasc Surg , vol.4 , pp. 182-194
    • Moore, W.S.1
  • 3
    • 0028842765 scopus 로고
    • Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions
    • Marin ML, Veith FJ, Cynamon J, Sanchez LA, et al. Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions. Ann Surg 1995;222:449-69.
    • (1995) Ann Surg , vol.222 , pp. 449-469
    • Marin, M.L.1    Veith, F.J.2    Cynamon, J.3    Sanchez, L.A.4
  • 4
    • 0031019823 scopus 로고    scopus 로고
    • Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    • Blum U, Voshage G, Lammer J, et al. Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Engl J Med 1997;336:13-20.
    • (1997) N Engl J Med , vol.336 , pp. 13-20
    • Blum, U.1    Voshage, G.2    Lammer, J.3
  • 5
    • 0032972728 scopus 로고    scopus 로고
    • AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trial
    • Zarins CK, White RA, Schwarten D, et al. AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: multicenter prospective clinical trial. J Vasc Surg 1999;29:292-308.
    • (1999) J Vasc Surg , vol.29 , pp. 292-308
    • Zarins, C.K.1    White, R.A.2    Schwarten, D.3
  • 6
    • 0035117760 scopus 로고    scopus 로고
    • Update on the Talent aortic stem-graft: 3 Preliminary report from United States phase I and II trials
    • Criado FJ, Wilson EP, Fairman RM, Abul-Khoudoud O, Wellons E. Update on the Talent aortic stem-graft: 3 preliminary report from United States phase I and II trials. J Vasc Surg 2001;33(2 Suppl):S146-9.
    • (2001) J Vasc Surg , vol.33 , pp. S146-S149
    • Criado, F.J.1    Wilson, E.P.2    Fairman, R.M.3    Abul-Khoudoud, O.4    Wellons, E.5
  • 7
    • 0034042336 scopus 로고    scopus 로고
    • Aneurysm rupture after endovascular repair using the AneuRx stem graft
    • Zarins CK, White RA, Fogarty TJ. Aneurysm rupture after endovascular repair using the AneuRx stem graft. J Vasc Surg 2000;31:960-70.
    • (2000) J Vasc Surg , vol.31 , pp. 960-970
    • Zarins, C.K.1    White, R.A.2    Fogarty, T.J.3
  • 8
    • 0035115532 scopus 로고    scopus 로고
    • Midterm durability of abdominal aortic aneurysm endograft repair: A word of caution
    • Holzbein TJ, Kretschmer G, Thurnher S, et al. Midterm durability of abdominal aortic aneurysm endograft repair: a word of caution. J Vasc Surg 2001;33(2 Pt 2):46-54.
    • (2001) J Vasc Surg , vol.33 , pp. 46-54
    • Holzbein, T.J.1    Kretschmer, G.2    Thurnher, S.3
  • 9
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience. European collaborators on stem/graft techniques for aortic aneurysm repair
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European collaborators on stem/graft techniques for aortic aneurysm repair. J Vasc Surg 2000;32:739-49.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 10
    • 1642336911 scopus 로고    scopus 로고
    • Increasing incidence of mid and long-term complications after endovascular graft repair of AAAs: A note of caution based on a 9-year experience
    • Ohki T, Veith FJ, Shaw P, et al. Increasing incidence of mid and long-term complications after endovascular graft repair of AAAs: a note of caution based on a 9-year experience. Ann Surg 2001;234:323-34.
    • (2001) Ann Surg , vol.234 , pp. 323-334
    • Ohki, T.1    Veith, F.J.2    Shaw, P.3
  • 11
    • 0030947672 scopus 로고    scopus 로고
    • Endoleaks as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • White GH, Yu W, May J, et al. Endoleaks as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg 1997;4:152-68.
    • (1997) J Endovasc Surg , vol.4 , pp. 152-168
    • White, G.H.1    Yu, W.2    May, J.3
  • 12
    • 0033360826 scopus 로고    scopus 로고
    • Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention
    • Gilling-Smith G, Brennan J, Harris P, et al. Endotension after endovascular aneurysm repair: definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 1999;6:305-7.
    • (1999) J Endovasc Surg , vol.6 , pp. 305-307
    • Gilling-Smith, G.1    Brennan, J.2    Harris, P.3
  • 13
    • 0034235048 scopus 로고    scopus 로고
    • Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial
    • Zarins CK, White RA, Hodgson KJ, et al. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg 2000;32:90-107.
    • (2000) J Vasc Surg , vol.32 , pp. 90-107
    • Zarins, C.K.1    White, R.A.2    Hodgson, K.J.3
  • 15
    • 0034526799 scopus 로고    scopus 로고
    • How should endotension be defined? History of a concept and evolution of a new term
    • White GH, May J. How should endotension be defined? History of a concept and evolution of a new term. J Endovasc Ther 2000;7:435-8.
    • (2000) J Endovasc Ther , vol.7 , pp. 435-438
    • White, G.H.1    May, J.2
  • 16
    • 0035145775 scopus 로고    scopus 로고
    • Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms
    • Baum RA, Carpenter JP, Cope C, et al. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 2001;33:32-41.
    • (2001) J Vasc Surg , vol.33 , pp. 32-41
    • Baum, R.A.1    Carpenter, J.P.2    Cope, C.3
  • 17
    • 19244367643 scopus 로고    scopus 로고
    • Endoleak after endovascular graft repair of experimental aortic aneurysms: Does coil embolization with angiographic "seal" lower intraaneurysmal pressure?
    • Many B, Sanchez LA, Ohki T, et al. Endoleak after endovascular graft repair of experimental aortic aneurysms: does coil embolization with angiographic "seal" lower intraaneurysmal pressure? J Vasc Surg 1998;27:454-62.
    • (1998) J Vasc Surg , vol.27 , pp. 454-462
    • Many, B.1    Sanchez, L.A.2    Ohki, T.3
  • 18
    • 0033931527 scopus 로고    scopus 로고
    • Continued sac expansion in the absence of demonstrable endoleak is an indication for secondary intervention
    • Fisher RK, Brennan JA, Gilling-Smith GL, et ai. Continued sac expansion in the absence of demonstrable endoleak is an indication for secondary intervention. Eur J Vasc Endovasc Surg 2000;20:96-8.
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , pp. 96-98
    • Fisher, R.K.1    Brennan, J.A.2    Gilling-Smith, G.L.3    Ai, E.4
  • 19
    • 0034940426 scopus 로고    scopus 로고
    • All sealed endoleaks are not the same: A treatment strategy based on an ex vivo analysis
    • Mehta M, Ohki T, Veith FJ, et al. All sealed endoleaks are not the same: a treatment strategy based on an ex vivo analysis. Eur J Vasc Endovasc Surg 2001;21:541-4.
    • (2001) Eur J Vasc Endovasc Surg , vol.21 , pp. 541-544
    • Mehta, M.1    Ohki, T.2    Veith, F.J.3
  • 20
    • 0034060255 scopus 로고    scopus 로고
    • Thrombus within an aortic aneurysm does not reduce pressure on the aneurysm wall
    • Schurink GWH, van Baalen JM, Viser MJT, et al. Thrombus within an aortic aneurysm does not reduce pressure on the aneurysm wall. J Vasc Surg 2000;31:501-6.
    • (2000) J Vasc Surg , vol.31 , pp. 501-506
    • Schurink, G.W.H.1    Van Baalen, J.M.2    Viser, M.J.T.3
  • 21
    • 0031821534 scopus 로고    scopus 로고
    • Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter
    • Resch T, Ivancev K, Lindh M, et al. Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter. J Vasc Surg 1998;28:242-9.
    • (1998) J Vasc Surg , vol.28 , pp. 242-249
    • Resch, T.1    Ivancev, K.2    Lindh, M.3
  • 22
    • 0034061745 scopus 로고    scopus 로고
    • Late abdominal aortic aneurysm rupture after AneuRx repair: A report of three cases
    • Politz JK, Newman VS, Stewart MT. Late abdominal aortic aneurysm rupture after AneuRx repair: a report of three cases. J Vasc Surg 2000;31:599-606.
    • (2000) J Vasc Surg , vol.31 , pp. 599-606
    • Politz, J.K.1    Newman, V.S.2    Stewart, M.T.3
  • 23
    • 0035099032 scopus 로고    scopus 로고
    • Diameter changes in isolated iliac artery aneurysms 1 to 6 years after endovascular graft repair
    • Sahgal A, Veith FJ, Lipsitz E, et al. Diameter changes in isolated iliac artery aneurysms 1 to 6 years after endovascular graft repair. J Vasc Surg 2001;33:289-95.
    • (2001) J Vasc Surg , vol.33 , pp. 289-295
    • Sahgal, A.1    Veith, F.J.2    Lipsitz, E.3
  • 24
    • 0033934886 scopus 로고    scopus 로고
    • Retroperitoneal endoscopic ligation of lumbar and inferior mesenteric artery as a treatment of persistent endoleak after endovascular aortic aneurysm repair
    • Wissclink W, Cuesta MA, Berends PJ, et al. Retroperitoneal endoscopic ligation of lumbar and inferior mesenteric artery as a treatment of persistent endoleak after endovascular aortic aneurysm repair. J Vasc Surg 2000;31:1240-4.
    • (2000) J Vasc Surg , vol.31 , pp. 1240-1244
    • Wissclink, W.1    Cuesta, M.A.2    Berends, P.J.3
  • 25
    • 0034001024 scopus 로고    scopus 로고
    • A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair
    • Greenberg R, Green R. A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair. J Vasc Surg 2000;31:836-7.
    • (2000) J Vasc Surg , vol.31 , pp. 836-837
    • Greenberg, R.1    Green, R.2
  • 26
    • 19044393090 scopus 로고    scopus 로고
    • Revised reporting standards for endovascular aortic aneurysm repair
    • Ad Hoc SVS/AAVS Committee for Standardized Reporting Practices for Endovascular Aortic Aneurysm Repair In press
    • Ad Hoc SVS/AAVS Committee for Standardized Reporting Practices for Endovascular Aortic Aneurysm Repair. Revised reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. In press 2002.
    • (2002) J Vasc Surg


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.