메뉴 건너뛰기




Volumn , Issue , 2010, Pages 243-248

Determination of glucose concentration from near-infrared spectra using principle component regression coupled with digital bandpass filter

Author keywords

Gaussian filter; Glucose; NIR; Noninvasive; PCR

Indexed keywords

CHEBYSHEV FILTER; CONTROLLED ENVIRONMENT; DIFFERENT ORDER; DIGITAL BANDPASS; FILTER PARAMETER; FREQUENCY DOMAINS; GAUSSIAN FILTERING; GAUSSIAN FILTERS; GAUSSIANS; GLUCOSE CONCENTRATION; NEAR INFRARED SPECTRA; NIR; NIR SPECTRUM; NONINVASIVE; PCR; PRINCIPAL COMPONENT REGRESSION; PRINCIPLE COMPONENT REGRESSION; RESPONSE SURFACE METHOD; STANDARD ERROR OF PREDICTION; TIME DOMAIN; TIME DOMAIN FILTERING; TRIACETIN;

EID: 78650389013     PISSN: 15206130     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SIPS.2010.5624795     Document Type: Conference Paper
Times cited : (15)

References (21)
  • 1
    • 0006919819 scopus 로고    scopus 로고
    • Overview of Noninvasive Fluid Glucose Measurement Using Optical Techniques to Maintain Glucose Control in Diabetes Mellitus
    • R. W. Waynant, V. M. Chenault, "Overview of Noninvasive Fluid Glucose Measurement Using Optical Techniques to Maintain Glucose Control in Diabetes Mellitus," IEEE lasers and electro-optics society, vol. 12, No. 2, 1998.
    • (1998) IEEE Lasers and Electro-optics Society , vol.12 , Issue.2
    • Waynant, R.W.1    Chenault, V.M.2
  • 2
    • 0142134292 scopus 로고    scopus 로고
    • Evaluation of Selectivity and Robustness of Near Infrared Glucose Measurements Based on Short Scan Fourier Transform Infrared Interferograms
    • Mukire J. Wabomba, Gary W. Small, Mark A. Arnold., " Evaluation of Selectivity and Robustness of Near Infrared Glucose Measurements Based on Short Scan Fourier Transform Infrared Interferograms," Analytical Chimica Acta 490, pp 325-340,2003
    • (2003) Analytical Chimica Acta , vol.490 , pp. 325-340
    • Wabomba, M.J.1    Small, G.W.2    Arnold, M.A.3
  • 4
    • 34247134514 scopus 로고    scopus 로고
    • Noninvasive Glucose Monitoring: Assessment of Technologies and Devices According to Quantitative Criteria
    • Andrea Tura, Alberto Maran, Giovanni Pacini ,"noninvasive Glucose Monitoring: Assessment of Technologies and Devices According to Quantitative Criteria," Diabetes Research and Clinical Practice 77, pp16-40,2007
    • (2007) Diabetes Research and Clinical Practice , vol.77 , pp. 16-40
    • Tura, A.1    Maran, A.2    Pacini, G.3
  • 5
    • 0032995738 scopus 로고    scopus 로고
    • Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
    • Omar S. Khalil, "Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements," Clinical chemistry, vol. 45:2 ,pp165-177 (1999).
    • (1999) Clinical Chemistry , vol.45 , Issue.2 , pp. 165-177
    • Khalil, O.S.1
  • 6
    • 0025072502 scopus 로고
    • Determination of Physiological Levels of Glucose in an Aqueous Matrix with Digitally Filtered Fourier Transform Near-Infrared Spectra
    • American Chemical Society
    • Mark A. Arnold and Gary W. Small, "Determination of Physiological Levels of Glucose in an Aqueous Matrix with Digitally Filtered Fourier Transform Near-Infrared Spectra," Analytical chemistry ,American Chemical Society, vol. 62:1414, pp 1457-1464, 1990.
    • (1990) Analytical Chemistry , vol.62 , Issue.1414 , pp. 1457-1464
    • Arnold, M.A.1    Small, G.W.2
  • 7
    • 0029249667 scopus 로고
    • Simultaneous Measurement of Glucose and Glutamine in Aqueous Solutions by Near Infrared Spectroscoping
    • Hoeil Chung Mark A Arnold, Martin Rhiel and David W. Murphammer, "Simultaneous Measurement of Glucose and Glutamine in Aqueous Solutions by Near Infrared Spectroscoping," Applied Biochemistry and Biotechnology, vol. 50, page 109- 125, 1995
    • (1995) Applied Biochemistry and Biotechnology , vol.50 , pp. 109-125
    • Chung, H.1    Arnold, M.A.2    Rhiel, M.3    Murphammer, D.W.4
  • 8
    • 0027918243 scopus 로고
    • Strategies for Coupling Digital Filtering with Partial least squares Regression: Application to the Determination of Glucose in Plasma by Fourier Transform Near- Infrared Spectroscopy
    • Gary W. Small, Mark A. Arnold, and Lois A. Marquadt,"Strategies for Coupling Digital Filtering with Partial least squares Regression: Application to the Determination of Glucose in Plasma by Fourier Transform Near- Infrared Spectroscopy," Anal Chemistry, vol. 65, pp 3279-3289,1993
    • (1993) Anal Chemistry , vol.65 , pp. 3279-3289
    • Small, G.W.1    Arnold, M.A.2    Marquadt, L.A.3
  • 9
    • 0031573222 scopus 로고    scopus 로고
    • Determination of Glucose in a Biological Matrix by Multivariate Analysis of Multiple Bandpass Filtered Fourier Transform Near- Infrared Interfeograms
    • Mutua J. Mattu, Gary W. Small, and Mark A. Arnold, "Determination of Glucose in a Biological Matrix by Multivariate Analysis of Multiple Bandpass Filtered Fourier Transform Near- Infrared Interfeograms,"Analy Chem, vol. 69, issue 22, pp 4695-4702, 1997.
    • (1997) Analy Chem , vol.69 , Issue.22 , pp. 4695-4702
    • Mattu, M.J.1    Small, G.W.2    Arnold, M.A.3
  • 10
    • 0030050878 scopus 로고    scopus 로고
    • Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum
    • Fredric M Hamy, Glenn M Cohenz ,"Multivariate determination of glucose concentrations from optimally filtered frequency-warped NIR spectra of human blood serum," Physiol. Meas., vol.17, pp 1-20, 1996.
    • (1996) Physiol. Meas. , vol.17 , pp. 1-20
    • Hamy, F.M.1    Cohenz, G.M.2
  • 11
    • 0031172752 scopus 로고    scopus 로고
    • Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time domain filtering and partial least squares regression
    • Fredric M. Ham, Ivica Kostanic, Glenn M Cohn, and Brent R. Gooch ,"Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time domain filtering and partial least squares regression," IEEE Transactions on Biomedical Engineering, vol. 44, Issue 6, pp75-485,1997.
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.6 , pp. 75-485
    • Ham, F.M.1    Kostanic, I.2    Cohn, G.M.3    Gooch, B.R.4
  • 13
    • 0037319952 scopus 로고    scopus 로고
    • Principal Components Regression with Data-Chosen Components and Related Methods
    • JTG Hwang, D Nettleton,"Principal Components Regression With Data-Chosen Components and Related Methods," Technometrics, vol. 45, N0. 1, pp 70, 2003
    • (2003) Technometrics , vol.45 , Issue.1 , pp. 70
    • Hwang, J.T.G.1    Nettleton, D.2
  • 14
    • 0037089106 scopus 로고    scopus 로고
    • Spectroscopic Evaluation of Glucose Concentration in Phosphate- Buffer Saline Solution Using Principle Component Analysis
    • Atsushi Nakamura, Takeshi Hasegawa, Jujiro Nishijo, Masav Kanazawa, Katsuo Aizawan, Takayuki Sota," Spectroscopic Evaluation of Glucose Concentration in Phosphate- Buffer Saline Solution Using Principle Component Analysis," Jpn. Appl. Phys. Vol. 41, pp. L440-L442. part 2, No. 4B, 2002
    • (2002) Jpn. Appl. Phys. , vol.41 , Issue.PART 2 AND NO. 4B
    • Nakamura, A.1    Hasegawa, T.2    Nishijo, J.3    Kanazawa, M.4    Aizawan, K.5    Sota, T.6
  • 19
    • 0037264275 scopus 로고    scopus 로고
    • A Constrained EM Algorithm for Principal Component Analysis
    • Jong-Hoon Ahn, Jong-Hoon Oh,"A Constrained EM Algorithm for Principal Component Analysis," Neural Computation, vol. 15, No. 1, page 57-65,2003.
    • (2003) Neural Computation , vol.15 , Issue.1 , pp. 57-65
    • Ahn, J.-H.1    Oh, J.-H.2
  • 20
    • 34248203587 scopus 로고    scopus 로고
    • Component retention in principal component analysis with application to cDNA microarray data
    • doi:10.1186/1745-6150-2-2
    • Richard Cangelosi, Alain Goriely ,"Component retention in principal component analysis with application to cDNA microarray data," Biology Direct, 2:2doi:10.1186/1745-6150-2-2,2007
    • (2007) Biology Direct , vol.2 , pp. 2
    • Cangelosi, R.1    Goriely, A.2
  • 21
    • 0027332773 scopus 로고
    • Stopping rules in principal components analysis: A comparison of heuristical and statistical approaches
    • Durham
    • Da Jackson, "Stopping rules in principal components analysis: a comparison of heuristical and statistical approaches," Ecology (Durham), vol.74:88, pp 2204-2214, 1993.
    • (1993) Ecology , vol.74 , Issue.88 , pp. 2204-2214
    • Jackson, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.