-
1
-
-
0024841188
-
Dynamic cardiac MR imaging techniques and applications
-
1:STN:280:DyaK3c%2FmvV2iug%3D%3D 2685881
-
RI Pettigrew 1989 Dynamic cardiac MR imaging techniques and applications Radiol Clin North Am 27 1183 1203 1:STN:280:DyaK3c%2FmvV2iug%3D%3D 2685881
-
(1989)
Radiol Clin North Am
, vol.27
, pp. 1183-1203
-
-
Pettigrew, R.I.1
-
2
-
-
0037561208
-
Comparison of cardiac MRI on 1.5 and 3.0 Tesla clinical whole body systems
-
DOI 10.1097/00004424-200307000-00009
-
DP Hinton LL Wald J Pitts F Schmitt 2003 Comparison of cardiac MRI on 1.5 and 3.0 Tesla clinical whole body systems Invest Radiol 38 436 442 10.1097/00004424-200307000-00009 12821858 (Pubitemid 36791338)
-
(2003)
Investigative Radiology
, vol.38
, Issue.7
, pp. 436-442
-
-
Hinton, D.P.1
Wald, L.L.2
Pitts, J.3
Schmitt, F.4
-
3
-
-
33646337946
-
Comprehensive cardiac magnetic resonance imaging at 3.0 tesla: Feasibility and implications for clinical applications
-
DOI 10.1097/01.rli.0000195840.50230.10, PII 0000442420060200000014
-
M Gutberlet R Noeske K Schwinge P Freyhardt R Felix T Niendorf 2006 Comprehensive cardiac magnetic resonance imaging at 3.0 Tesla: feasibility and implications for clinical applications Invest Radiol 41 154 167 10.1097/01.rli.0000195840.50230.10 16428987 (Pubitemid 44406213)
-
(2006)
Investigative Radiology
, vol.41
, Issue.2
, pp. 154-167
-
-
Gutberlet, M.1
Noeske, R.2
Schwinge, K.3
Freyhardt, P.4
Felix, R.5
Niendorf, T.6
-
4
-
-
0031884051
-
Ultimate intrinsic signal-to-noise ratio in MRI
-
DOI 10.1002/mrm.1910390317
-
O Ocali E Atalar 1998 Ultimate intrinsic signal-to-noise ratio in MRI Magn Reson Med 39 462 473 1:STN:280:DyaK1c7lvVelug%3D%3D 10.1002/mrm.1910390317 9498603 (Pubitemid 28128390)
-
(1998)
Magnetic Resonance in Medicine
, vol.39
, Issue.3
, pp. 462-473
-
-
Ocali, O.1
Atalar, E.2
-
6
-
-
70349673301
-
In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI
-
10.1212/WNL.0b013e3181b64bf7 19641168
-
C Mainero T Benner A Radding A van der Kouwe R Jensen BR Rosen RP Kinkel 2009 In vivo imaging of cortical pathology in multiple sclerosis using ultra-high field MRI Neurology 73 941 948 10.1212/WNL.0b013e3181b64bf7 19641168
-
(2009)
Neurology
, vol.73
, pp. 941-948
-
-
Mainero, C.1
Benner, T.2
Radding, A.3
Van Der Kouwe, A.4
Jensen, R.5
Rosen, B.R.6
Kinkel, R.P.7
-
7
-
-
60349095739
-
Whole-body imaging at 7 T: Preliminary results
-
10.1002/mrm.21751 19097214
-
JT Vaughan CJ Snyder LJ DelaBarre PJ Bolan J Tian L Bolinger G Adriany P Andersen J Strupp K Ugurbil 2009 Whole-body imaging at 7 T: preliminary results Magn Reson Med 61 244 248 10.1002/mrm.21751 19097214
-
(2009)
Magn Reson Med
, vol.61
, pp. 244-248
-
-
Vaughan, J.T.1
Snyder, C.J.2
Delabarre, L.J.3
Bolan, P.J.4
Tian, J.5
Bolinger, L.6
Adriany, G.7
Andersen, P.8
Strupp, J.9
Ugurbil, K.10
-
9
-
-
70350709890
-
Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope
-
10.1097/RLI.0b013e3181b4c15e 19652614
-
T Frauenrath F Hezel U Heinrichs S Kozerke JF Utting M Kob C Butenweg P Boesiger T Niendorf 2009 Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope Invest Radiol 44 539 547 10.1097/RLI.0b013e3181b4c15e 19652614
-
(2009)
Invest Radiol
, vol.44
, pp. 539-547
-
-
Frauenrath, T.1
Hezel, F.2
Heinrichs, U.3
Kozerke, S.4
Utting, J.F.5
Kob, M.6
Butenweg, C.7
Boesiger, P.8
Niendorf, T.9
-
10
-
-
0034806346
-
Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents
-
DOI 10.1002/jmri.1195
-
H Thiele E Nagel I Paetsch B Schnackenburg A Bornstedt M Kouwenhoven A Wahl G Schuler E Fleck 2001 Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents J Magn Reson Imaging 14 362 367 1:STN:280: DC%2BD3MrkvFKruw%3D%3D 10.1002/jmri.1195 11599059 (Pubitemid 32906553)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.14
, Issue.4
, pp. 362-367
-
-
Thiele, H.1
Nagel, E.2
Paetsch, I.3
Schnackenburg, B.4
Bornstedt, A.5
Kouwenhoven, M.6
Wahl, A.7
Schuler, G.8
Fleck, E.9
-
12
-
-
0037376138
-
TrueFISP - Technical considerations and cardiovascular applications
-
DOI 10.1016/S0720-048X(02)00330-3
-
F Fuchs G Laub K Othomo 2003 TrueFISP-technical considerations and cardiovascular applications Eur J Radiol 46 28 32 10.1016/S0720-048X(02)00330-3 12648799 (Pubitemid 36332076)
-
(2003)
European Journal of Radiology
, vol.46
, Issue.1
, pp. 28-32
-
-
Fuchs, F.1
Laub, G.2
Othomo, K.3
-
13
-
-
33846817206
-
CMR of ventricular function
-
DOI 10.1111/j.1540-8175.2007.00375.x
-
NG Keenan DJ Pennell 2007 CMR of ventricular function Echocardiography 24 185 193 10.1111/j.1540-8175.2007.00375.x 17313554 (Pubitemid 46204407)
-
(2007)
Echocardiography
, vol.24
, Issue.2
, pp. 185-193
-
-
Keenan, N.G.1
Pennell, D.J.2
-
14
-
-
33749061448
-
ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging
-
10.1016/j.jacc.2006.07.003 17010819
-
RC Hendel MR Patel CM Kramer M Poon RC Hendel JC Carr NA Gerstad LD Gillam JM Hodgson RJ Kim CM Kramer JR Lesser ET Martin JV Messer RF Redberg GD Rubin JS Rumsfeld AJ Taylor WG Weigold PK Woodard RG Brindis RC Hendel PS Douglas ED Peterson MJ Wolk JM Allen MR Patel 2006 ACCF/ACR/SCCT/SCMR/ASNC/ NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology J Am Coll Cardiol 48 1475 1497 10.1016/j.jacc.2006.07. 003 17010819
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 1475-1497
-
-
Hendel, R.C.1
Patel, M.R.2
Kramer, C.M.3
Poon, M.4
Hendel, R.C.5
Carr, J.C.6
Gerstad, N.A.7
Gillam, L.D.8
Hodgson, J.M.9
Kim, R.J.10
Kramer, C.M.11
Lesser, J.R.12
Martin, E.T.13
Messer, J.V.14
Redberg, R.F.15
Rubin, G.D.16
Rumsfeld, J.S.17
Taylor, A.J.18
Weigold, W.G.19
Woodard, P.K.20
Brindis, R.G.21
Hendel, R.C.22
Douglas, P.S.23
Peterson, E.D.24
Wolk, M.J.25
Allen, J.M.26
Patel, M.R.27
more..
-
15
-
-
77952096359
-
Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T
-
10.1007/s00330-009-1676-z 20013275
-
M Becker T Frauenrath F Hezel GA Krombach U Kremer B Koppers C Butenweg A Goemmel JF Utting J Schulz-Menger T Niendorf 2009 Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram- triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T Eur Radiol 20 1344 1355 10.1007/s00330-009-1676-z 20013275
-
(2009)
Eur Radiol
, vol.20
, pp. 1344-1355
-
-
Becker, M.1
Frauenrath, T.2
Hezel, F.3
Krombach, G.A.4
Kremer, U.5
Koppers, B.6
Butenweg, C.7
Goemmel, A.8
Utting, J.F.9
Schulz-Menger, J.10
Niendorf, T.11
-
16
-
-
39549088310
-
Acoustic method for synchronization of Magnetic Resonance Imaging (MRI)
-
DOI 10.3813/AAA.918017
-
T Frauenrath T Niendorf M Kob 2008 Acoustic method for synchronization of magnetic resonance imaging (MRI) Acta Acust 94 148 155 10.3813/AAA.918017 (Pubitemid 351281308)
-
(2008)
Acta Acustica united with Acustica
, vol.94
, Issue.1
, pp. 148-155
-
-
Frauenrath, T.1
Niendorf, T.2
Kob, M.3
-
17
-
-
0036104746
-
Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
-
10.1148/radiol.2233011181 12034951
-
JC Moon CH Lorenz JM Francis GC Smith DJ Pennell 2002 Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility Radiology 223 789 797 10.1148/radiol.2233011181 12034951
-
(2002)
Radiology
, vol.223
, pp. 789-797
-
-
Moon, J.C.1
Lorenz, C.H.2
Francis, J.M.3
Smith, G.C.4
Pennell, D.J.5
-
18
-
-
33745889016
-
Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance
-
1:STN:280:DC%2BD28zkt1Cgtg%3D%3D 10.1080/10976640600572889 16755827
-
AM Maceira SK Prasad M Khan DJ Pennell 2006 Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance J Cardiovasc Magn Reson 8 417 426 1:STN:280: DC%2BD28zkt1Cgtg%3D%3D 10.1080/10976640600572889 16755827
-
(2006)
J Cardiovasc Magn Reson
, vol.8
, pp. 417-426
-
-
MacEira, A.M.1
Prasad, S.K.2
Khan, M.3
Pennell, D.J.4
-
19
-
-
34547882725
-
Balanced steady-state free precession vs. segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla
-
DOI 10.1002/jmri.20986
-
F Grothues H Boenigk J Graessner M Kanowski HU Klein 2007 Balanced steady-state free precession vs. segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla J Magn Reson Imaging 26 392 400 10.1002/jmri.20986 17623890 (Pubitemid 47257739)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.2
, pp. 392-400
-
-
Grothues, F.1
Boenigk, H.2
Graessner, J.3
Kanowski, M.4
Klein, H.U.5
-
20
-
-
38949155506
-
Highly accelerated cardiovascular MR imaging using many channel technology: Concepts and clinical applications
-
DOI 10.1007/s00330-007-0692-0
-
T Niendorf DK Sodickson 2008 Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications Eur Radiol 18 87 102 10.1007/s00330-007-0692-0 17562047 (Pubitemid 351217280)
-
(2008)
European Radiology
, vol.18
, Issue.1
, pp. 87-102
-
-
Niendorf, T.1
Sodickson, D.K.2
-
21
-
-
68049103048
-
Simple RF design for human functional and morphological cardiac imaging at 7tesla
-
1:CAS:528:DC%2BD1MXps1CgtLs%3D 10.1016/j.jmr.2009.06.014 19595618
-
MJ Versluis N Tsekos NB Smith AG Webb 2009 Simple RF design for human functional and morphological cardiac imaging at 7tesla J Magn Reson 200 161 166 1:CAS:528:DC%2BD1MXps1CgtLs%3D 10.1016/j.jmr.2009.06.014 19595618
-
(2009)
J Magn Reson
, vol.200
, pp. 161-166
-
-
Versluis, M.J.1
Tsekos, N.2
Smith, N.B.3
Webb, A.G.4
-
22
-
-
0034870344
-
Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging
-
DOI 10.1002/jmri.1178
-
S Plein TN Bloomer JP Ridgway TR Jones GJ Bainbridge MU Sivananthan 2001 Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging J Magn Reson Imaging 14 230 236 1:STN:280:DC%2BD3MvptFyhuw%3D%3D 10.1002/jmri.1178 11536399 (Pubitemid 32801056)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.14
, Issue.3
, pp. 230-236
-
-
Plein, S.1
Bloomer, T.N.2
Ridgway, J.P.3
Jones, T.R.4
Bainbridge, G.J.5
Sivananthan, M.U.6
-
23
-
-
0035088021
-
MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
-
1:STN:280:DC%2BD3M7oslKntg%3D%3D 11274568
-
J Barkhausen SG Ruehm M Goyen T Buck G Laub JF Debatin 2001 MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study Radiology 219 264 269 1:STN:280:DC%2BD3M7oslKntg%3D%3D 11274568
-
(2001)
Radiology
, vol.219
, pp. 264-269
-
-
Barkhausen, J.1
Ruehm, S.G.2
Goyen, M.3
Buck, T.4
Laub, G.5
Debatin, J.F.6
-
24
-
-
0037373294
-
Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
-
DOI 10.1002/jmri.10262
-
K Alfakih S Plein H Thiele T Jones JP Ridgway MU Sivananthan 2003 Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences J Magn Reson Imaging 17 323 329 10.1002/jmri.10262 12594722 (Pubitemid 36259246)
-
(2003)
Journal of Magnetic Resonance Imaging
, vol.17
, Issue.3
, pp. 323-329
-
-
Alfakih, K.1
Plein, S.2
Thiele, H.3
Jones, T.4
Ridgway, J.P.5
Sivananthan, M.U.6
-
25
-
-
0036830009
-
MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique
-
DOI 10.1002/jmri.10197
-
W Li JS Stern VM Mai LN Pierchala RR Edelman PV Prasad 2002 MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique J Magn Reson Imaging 16 559 564 10.1002/jmri.10197 12412033 (Pubitemid 35257763)
-
(2002)
Journal of Magnetic Resonance Imaging
, vol.16
, Issue.5
, pp. 559-564
-
-
Li, W.1
Stern, J.S.2
Mai, V.M.3
Pierchala, L.N.4
Edelman, R.R.5
Prasad, P.V.6
-
26
-
-
33746886987
-
Determination of cardiac volumes and mass with FLASH and SSFP cine sequences at 1.5 vs. 3 Tesla: A validation study
-
DOI 10.1002/jmri.20638
-
LE Hudsmith SE Petersen DJ Tyler JM Francis AS Cheng K Clarke JB Selvanayagam MD Robson S Neubauer 2006 Determination of cardiac volumes and mass with FLASH and SSFP cine sequences at 1.5 vs. 3 Tesla: a validation study J Magn Reson Imaging 24 312 318 10.1002/jmri.20638 16795076 (Pubitemid 44188556)
-
(2006)
Journal of Magnetic Resonance Imaging
, vol.24
, Issue.2
, pp. 312-318
-
-
Hudsmith, L.E.1
Petersen, S.E.2
Tyler, D.J.3
Francis, J.M.4
Cheng, A.S.H.5
Clarke, K.6
Selvanayagam, J.B.7
Robson, M.D.8
Neubauer, S.9
-
27
-
-
46849103146
-
Cardiac cine MRI: Quantification of the relationship between fast gradient echo and steady-state free precession for determination of myocardial mass and volumes
-
DOI 10.1002/jmri.21405
-
AA Malayeri WC Johnson R Macedo J Bathon JA Lima DA Bluemke 2008 Cardiac cine MRI: quantification of the relationship between fast gradient echo and steady-state free precession for determination of myocardial mass and volumes J Magn Reson Imaging 28 60 66 10.1002/jmri.21405 18581356 (Pubitemid 351956466)
-
(2008)
Journal of Magnetic Resonance Imaging
, vol.28
, Issue.1
, pp. 60-66
-
-
Malayeri, A.A.1
Johnson, W.C.2
Macedo, R.3
Bathon, J.4
Lima, J.A.C.5
Bluemke, D.A.6
-
28
-
-
70350494909
-
Feasibility of cardiovascular magnetic resonance to assess the orifice area of aortic bioprostheses
-
10.1161/CIRCIMAGING.108.840967
-
F von Knobelsdorff-Brenkenhoff A Rudolph R Wassmuth S Bohl EE Buschmann H Abdel-Aty R Dietz J Schulz-Menger 2009 Feasibility of cardiovascular magnetic resonance to assess the orifice area of aortic bioprostheses Circ Cardiovasc Imaging 2 397 404 10.1161/CIRCIMAGING.108.840967
-
(2009)
Circ Cardiovasc Imaging
, vol.2
, pp. 397-404
-
-
Von Knobelsdorff-Brenkenhoff, F.1
Rudolph, A.2
Wassmuth, R.3
Bohl, S.4
Buschmann, E.E.5
Abdel-Aty, H.6
Dietz, R.7
Schulz-Menger, J.8
|