메뉴 건너뛰기




Volumn 28, Issue 1, 2008, Pages 60-66

Cardiac cine MRI: Quantification of the relationship between fast gradient echo and steady-state free precession for determination of myocardial mass and volumes

Author keywords

Fast gradient echo; Magnetic resonance imaging; Normal cardiac function; Steady state free precession

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; FEMALE; HEART EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE FUNCTION; HEART OUTPUT; HEART STROKE VOLUME; HEART VOLUME; HEART WEIGHT; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 46849103146     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21405     Document Type: Article
Times cited : (69)

References (18)
  • 1
    • 0033879659 scopus 로고    scopus 로고
    • Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?
    • Bellenger NG, Burgess MI, Ray SG, et al. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 2000;21:1387-1396.
    • (2000) Eur Heart J , vol.21 , pp. 1387-1396
    • Bellenger, N.G.1    Burgess, M.I.2    Ray, S.G.3
  • 2
    • 0028927470 scopus 로고
    • Magnetic resonance imaging compared to echocardiography to assess left ventricular mass in the hypertensive patient
    • Bottini PB, Carr AA, Prisant LM, Flickinger FW, Allison JD, Gottdiener JS. Magnetic resonance imaging compared to echocardiography to assess left ventricular mass in the hypertensive patient. Am J Hypertens 1995;8:221-228.
    • (1995) Am J Hypertens , vol.8 , pp. 221-228
    • Bottini, P.B.1    Carr, A.A.2    Prisant, L.M.3    Flickinger, F.W.4    Allison, J.D.5    Gottdiener, J.S.6
  • 3
    • 0036642629 scopus 로고    scopus 로고
    • Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    • Grothues F, Smith GC, Moon JC, et al. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 2002;90:29-34.
    • (2002) Am J Cardiol , vol.90 , pp. 29-34
    • Grothues, F.1    Smith, G.C.2    Moon, J.C.3
  • 4
    • 0027512694 scopus 로고
    • Left ventricular measurements with cine and spin-echo MR imaging: A study of reproducibility with variance component analysis
    • Pattynama PM, Lamb HJ, van der Velde EA, van der Wall EE, de Roos A. Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 1993;187:261-268.
    • (1993) Radiology , vol.187 , pp. 261-268
    • Pattynama, P.M.1    Lamb, H.J.2    van der Velde, E.A.3    van der Wall, E.E.4    de Roos, A.5
  • 5
    • 0036104746 scopus 로고    scopus 로고
    • Breathhold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ. Breathhold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 2002;223:789-797.
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.C.1    Lorenz, C.H.2    Francis, J.M.3    Smith, G.C.4    Pennell, D.J.5
  • 6
    • 0035088021 scopus 로고    scopus 로고
    • MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study
    • Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 2001;219:264-269.
    • (2001) Radiology , vol.219 , pp. 264-269
    • Barkhausen, J.1    Ruehm, S.G.2    Goyen, M.3    Buck, T.4    Laub, G.5    Debatin, J.F.6
  • 7
    • 0036840537 scopus 로고    scopus 로고
    • Multi-ethnic study of atherosclerosis: Objectives and design
    • Bild DE, Bluemke DA, Burke GL, et al. Multi-ethnic study of atherosclerosis: objectives and design. Am J Epidemiol 2002;156:871-881.
    • (2002) Am J Epidemiol , vol.156 , pp. 871-881
    • Bild, D.E.1    Bluemke, D.A.2    Burke, G.L.3
  • 8
    • 33745541684 scopus 로고    scopus 로고
    • Cardiovascular function in multiethnic study of atherosclerosis: Normal values by age, sex, and ethnicity
    • Natori S, Lai S, Finn JP, et al. Cardiovascular function in multiethnic study of atherosclerosis: normal values by age, sex, and ethnicity. AJR Am J Roentgenol 2006;186:S357-365.
    • (2006) AJR Am J Roentgenol , vol.186
    • Natori, S.1    Lai, S.2    Finn, J.P.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0035023617 scopus 로고    scopus 로고
    • Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    • Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP. Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 2001;219:828-834.
    • (2001) Radiology , vol.219 , pp. 828-834
    • Carr, J.C.1    Simonetti, O.2    Bundy, J.3    Li, D.4    Pereles, S.5    Finn, J.P.6
  • 11
    • 0034870344 scopus 로고    scopus 로고
    • Steady-state free precession magnetic resonance imaging of tile heart: Comparison with segmented k-space gradient-echo imaging
    • Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU. Steady-state free precession magnetic resonance imaging of tile heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 2001;14:230-236.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 230-236
    • Plein, S.1    Bloomer, T.N.2    Ridgway, J.P.3    Jones, T.R.4    Bainbridge, G.J.5    Sivananthan, M.U.6
  • 12
    • 0034806346 scopus 로고    scopus 로고
    • Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents
    • Thiele H, Nagel E, Paetsch I, et al. Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. J Magn Reson Imaging 2001;14:362-367.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 362-367
    • Thiele, H.1    Nagel, E.2    Paetsch, I.3
  • 13
    • 0037373294 scopus 로고    scopus 로고
    • Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    • Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU. Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 2003;17:323-329.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 323-329
    • Alfakih, K.1    Plein, S.2    Thiele, H.3    Jones, T.4    Ridgway, J.P.5    Sivananthan, M.U.6
  • 14
    • 0036360818 scopus 로고    scopus 로고
    • Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession
    • Thiele H, Paetsch I, Schnackenburg B, et al. Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession. J Cardiovasc Magn Reson 2002;4:327-339.
    • (2002) J Cardiovasc Magn Reson , vol.4 , pp. 327-339
    • Thiele, H.1    Paetsch, I.2    Schnackenburg, B.3
  • 15
    • 0038560023 scopus 로고    scopus 로고
    • Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: Comparison with left ventricular angiography
    • Ichikawa Y, Sakuma H, Kitagawa K, et al. Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography. J Cardiovasc Magn Reson 2003;5:333-342.
    • (2003) J Cardiovasc Magn Reson , vol.5 , pp. 333-342
    • Ichikawa, Y.1    Sakuma, H.2    Kitagawa, K.3
  • 16
    • 0036830009 scopus 로고    scopus 로고
    • MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique
    • Li W, Stern JS, Mai VM, Pierchala LN, Edelman RR, Prasad PV. MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique. J Magn Reson Imaging 2002;16:559-564.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 559-564
    • Li, W.1    Stern, J.S.2    Mai, V.M.3    Pierchala, L.N.4    Edelman, R.R.5    Prasad, P.V.6
  • 17
    • 33745276499 scopus 로고    scopus 로고
    • Left ventricular papillary muscle mass: Relationship to left ventricular mass and volumes by magnetic resonance imaging
    • Vogel-Claussen J, Finn JP, Gomes AS, et al. Left ventricular papillary muscle mass: relationship to left ventricular mass and volumes by magnetic resonance imaging. J Comput Assist Tomogr 2006;30:426-432.
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 426-432
    • Vogel-Claussen, J.1    Finn, J.P.2    Gomes, A.S.3
  • 18
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence
    • Atkinson DJ, Edelman RR. Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. Radiology 1991;178:357-360.
    • (1991) Radiology , vol.178 , pp. 357-360
    • Atkinson, D.J.1    Edelman, R.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.