메뉴 건너뛰기




Volumn 54, Issue 10, 2010, Pages 1248-1256

Spontaneous breathing during high-frequency oscillatory ventilation improves regional lung characteristics in experimental lung injury

Author keywords

[No Author keywords available]

Indexed keywords

ATROPINE; KETAMINE; MIDAZOLAM; PANCURONIUM BROMIDE; PROPOFOL; REMIFENTANIL;

EID: 78650209041     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2010.02323.x     Document Type: Article
Times cited : (17)

References (36)
  • 1
    • 0030902502 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for adult respiratory distress syndrome: Let's get it right this time!
    • Froese AB. High-frequency oscillatory ventilation for adult respiratory distress syndrome: let's get it right this time!. Crit Care Med 1997;25:906-8.
    • (1997) Crit. Care Med. , vol.25 , pp. 906-908
    • Froese, A.B.1
  • 2
    • 29844445334 scopus 로고    scopus 로고
    • Ventilator-induced lung injury: From the bench to the bedside
    • Tremblay LN, Slutsky AS. Ventilator-induced lung injury: from the bench to the bedside. Intensive Care Med 2006;32:24-33.
    • (2006) Intensive Care Med. , vol.32 , pp. 24-33
    • Tremblay, L.N.1    Slutsky, A.S.2
  • 4
    • 33748916413 scopus 로고    scopus 로고
    • Protective strategies of high-frequency oscillatory ventilation in a rabbit model
    • Meyer J, Cox PN, McKerlie C, Bienzle D. Protective strategies of high-frequency oscillatory ventilation in a rabbit model. Pediatr Res 2006;60:401-6.
    • (2006) Pediatr. Res. , vol.60 , pp. 401-406
    • Meyer, J.1    Cox, P.N.2    McKerlie, C.3    Bienzle, D.4
  • 6
    • 0032906772 scopus 로고    scopus 로고
    • Spontaneous breathing during ventilatory support improves ventilation-perfusion distributions in patients with acute respiratory distress syndrome
    • Putensen C, Mutz NJ, Putensen-Himmer G, Zinserling J. Spontaneous breathing during ventilatory support improves ventilation-perfusion distributions in patients with acute respiratory distress syndrome. Am J Respir Crit Care Med 1999;159:1241-8.
    • (1999) Am. J. Respir. Crit. Care Med. , vol.159 , pp. 1241-1248
    • Putensen, C.1    Mutz, N.J.2    Putensen-Himmer, G.3    Zinserling, J.4
  • 9
    • 14944364996 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation: Mechanisms of gas exchange and lung mechanics
    • Pillow JJ. High-frequency oscillatory ventilation: mechanisms of gas exchange and lung mechanics. Crit Care Med 2005;33: S135-41.
    • (2005) Crit. Care Med. , vol.33
    • Pillow, J.J.1
  • 10
    • 0037391378 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients
    • Derdak S. High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients. Crit Care Med 2003;31: S317-23.
    • (2003) Crit. Care Med. , vol.31
    • Derdak, S.1
  • 11
  • 13
    • 62849118115 scopus 로고    scopus 로고
    • Demand flow facilitates spontaneous breathing during high-frequency oscillatory ventilation in a pig model
    • van Heerde M, Roubik K, Kopelent V, Plötz FB, Markhorst DG. Demand flow facilitates spontaneous breathing during high-frequency oscillatory ventilation in a pig model. Crit Care Med 2009;37:1068-73.
    • (2009) Crit. Care Med. , vol.37 , pp. 1068-1073
    • Van Heerde, M.1    Roubik, K.2    Kopelent, V.3    Plötz, F.B.4    Markhorst, D.G.5
  • 14
    • 67649422713 scopus 로고    scopus 로고
    • Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: An experimental study
    • Richard JC, Pouzot C, Gros A, Tourevieille C, Lebars D, Lavenne F, Frerichz I, Guerin C. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study. Crit Care 2009;13: R821-9.
    • (2009) Crit. Care , vol.13
    • Richard, J.C.1    Pouzot, C.2    Gros, A.3    Tourevieille, C.4    Lebars, D.5    Lavenne, F.6    Frerichz, I.7    Guerin, C.8
  • 15
    • 33644999851 scopus 로고    scopus 로고
    • Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography
    • Hinz J, Moerer O, Neumann P, Dudykevych T, Frerichs I, Hellige G, Quintel M. Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography. Acta Anaesthesiol Scand 2006;50:331-9.
    • (2006) Acta Anaesthesiol Scand. , vol.50 , pp. 331-339
    • Hinz, J.1    Moerer, O.2    Neumann, P.3    Dudykevych, T.4    Frerichs, I.5    Hellige, G.6    Quintel, M.7
  • 16
    • 43049091496 scopus 로고    scopus 로고
    • Electrical impedance tomography: A future item on the 'Christmas wish list' of the intensivist?
    • Schibler A, Calzia E. Electrical impedance tomography: a future item on the 'Christmas wish list' of the intensivist? Intensive Care Med 2008;34:400-1.
    • (2008) Intensive Care Med. , vol.34 , pp. 400-401
    • Schibler, A.1    Calzia, E.2
  • 18
    • 0018863191 scopus 로고
    • In vivo lung lavage as an experimental model of the respiratory distress syndrome
    • Lachmann B, Robertson B, Vogel J. In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand 1980;24:231-6.
    • (1980) Acta Anaesthesiol Scand. , vol.24 , pp. 231-236
    • Lachmann, B.1    Robertson, B.2    Vogel, J.3
  • 19
    • 34447629903 scopus 로고    scopus 로고
    • Unloading work of breathing during high-frequency oscillatory ventilation: A bench study
    • van Heerde M, Roubik K, Kopelent V, Plötz FB, Markhorst DG. Unloading work of breathing during high-frequency oscillatory ventilation: a bench study. Crit Care 2006;10: R1031-7.
    • (2006) Crit. Care , vol.10
    • Van Heerde, M.1    Roubik, K.2    Kopelent, V.3    Plötz, F.B.4    Markhorst, D.G.5
  • 20
    • 0027024613 scopus 로고
    • Open up the lung and keep the lung open
    • Lachmann B. Open up the lung and keep the lung open. Intensive Care Med 1992;18:319-21.
    • (1992) Intensive Care Med. , vol.18 , pp. 319-321
    • Lachmann, B.1
  • 22
    • 0037861995 scopus 로고    scopus 로고
    • Electrical impedance tomography (EIT): A review
    • Brown BH. Electrical impedance tomography (EIT): a review. J Med Eng Technol 2003;27:97-108.
    • (2003) J. Med. Eng. Technol. , vol.27 , pp. 97-108
    • Brown, B.H.1
  • 24
    • 0029845456 scopus 로고    scopus 로고
    • Local mechanics of the lung tissue determined by functional EIT
    • Hahn G, Frerichs I, Kleyer M, Hellige G. Local mechanics of the lung tissue determined by functional EIT. Physiol Meas 1996;17(Suppl. 4 A): A159-66.
    • (1996) Physiol. Meas. , vol.17 , Issue.4 SUPPL. A
    • Hahn, G.1    Frerichs, I.2    Kleyer, M.3    Hellige, G.4
  • 25
    • 0037302128 scopus 로고    scopus 로고
    • Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver
    • van Genderingen HR, van Vught AJ, Jansen JR. Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver. Intensive Care Med 2003;29:233-40.
    • (2003) Intensive Care Med. , vol.29 , pp. 233-240
    • Van Genderingen, H.R.1    Van Vught, A.J.2    Jansen, J.R.3
  • 27
    • 0034975827 scopus 로고    scopus 로고
    • Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights
    • Frerichs I, Dudykevych T, Hinz J, Bodenstein M, Hahn G, Hellige G. Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights. J Appl Physiol 2001;91:39-50.
    • (2001) J. Appl. Physiol. , vol.91 , pp. 39-50
    • Frerichs, I.1    Dudykevych, T.2    Hinz, J.3    Bodenstein, M.4    Hahn, G.5    Hellige, G.6
  • 28
    • 34247595485 scopus 로고    scopus 로고
    • Regional filling characteristics of the lungs in mechanically ventilated patients with acute lung injury
    • Hinz J, Gehoff A, Moerer O, Frerichs I, Hahn G, Hellige G, Quintel M. Regional filling characteristics of the lungs in mechanically ventilated patients with acute lung injury. Eur J Anaesthesiol 2007;24:414-24.
    • (2007) Eur. J. Anaesthesiol , vol.24 , pp. 414-424
    • Hinz, J.1    Gehoff, A.2    Moerer, O.3    Frerichs, I.4    Hahn, G.5    Hellige, G.6    Quintel, M.7
  • 32
    • 33748413227 scopus 로고    scopus 로고
    • Spontaneous breathing with airway pressure release ventilation favors ventilation in dependent lung regions and counters cyclic alveolar collapse in oleic-acid-induced lung injury: A randomized controlled computed tomography trial
    • Wrigge H, Zinserling J, Neumann P, Muders T, Magnusson A, Putensen C, Hedenstierna G. Spontaneous breathing with airway pressure release ventilation favors ventilation in dependent lung regions and counters cyclic alveolar collapse in oleic-acid-induced lung injury: a randomized controlled computed tomography trial. Crit Care 2005;9: R780-9.
    • (2005) Crit. Care , vol.9
    • Wrigge, H.1    Zinserling, J.2    Neumann, P.3    Muders, T.4    Magnusson, A.5    Putensen, C.6    Hedenstierna, G.7
  • 33
    • 34248330950 scopus 로고    scopus 로고
    • Airway pressure release and biphasic intermittent positive airway pressure ventilation: Are they ready for prime time?
    • Seymour CW, Frazer M, Reilly PM, Fuchs BD. Airway pressure release and biphasic intermittent positive airway pressure ventilation: are they ready for prime time? J Trauma 2007;62:1298-308.
    • (2007) J. Trauma. , vol.62 , pp. 1298-1308
    • Seymour, C.W.1    Frazer, M.2    Reilly, P.M.3    Fuchs, B.D.4
  • 36


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.