메뉴 건너뛰기




Volumn 29, Issue 2, 2003, Pages 233-240

Estimation of regional lung volume changes by electrical impedance tomography during a pressure-volume maneuver

Author keywords

Acute lung injury; Electrical impedance; Lung compliance; Lung volume; Tomography

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; CURVE FITTING; LUNG INFLATION; LUNG INJURY; LUNG LAVAGE; LUNG PRESSURE; LUNG VOLUME; NONHUMAN; SWINE; VENTILATOR;

EID: 0037302128     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00134-002-1586-x     Document Type: Article
Times cited : (67)

References (30)
  • 1
    • 0027024613 scopus 로고
    • Open the lung and keep the lung open
    • Lachmann B (1992) Open the lung and keep the lung open. Intensive Care Meal 118:319-321
    • (1992) Intensive Care Meal , vol.118 , pp. 319-321
    • Lachmann, B.1
  • 3
    • 0029047924 scopus 로고
    • Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome
    • Gattinoni L, Pelosi P, Crotti S, Valenza F (1995) Effects of positive end-expiratory pressure on regional distribution of tidal volume and recruitment in adult respiratory distress syndrome. Am J Respir Crit Care Med 151:1807-1814
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 1807-1814
    • Gattinoni, L.1    Pelosi, P.2    Crotti, S.3    Valenza, F.4
  • 4
    • 0023473172 scopus 로고
    • Pressure-volume curve of total respiratory system in acute respiratory failure. Computed tomographic scan study
    • Gattinoni L, Pesenti A, Avalli L, Rossi F, Bombino M (1987) Pressure-volume curve of total respiratory system in acute respiratory failure. Computed tomographic scan study. Am Rev Respir Dis 136:730-736
    • (1987) Am Rev Respir Dis , vol.136 , pp. 730-736
    • Gattinoni, L.1    Pesenti, A.2    Avalli, L.3    Rossi, F.4    Bombino, M.5
  • 5
    • 0029082881 scopus 로고
    • Changes in the thoracic impedance under different ventilatory conditions
    • Hahn G, Spinova I, Baisch F, Hellige G (1995) Changes in the thoracic impedance under different ventilatory conditions. Physiol Meas 16:A161-A173
    • (1995) Physiol Meas , vol.16
    • Hahn, G.1    Spinova, I.2    Baisch, F.3    Hellige, G.4
  • 6
    • 0027300084 scopus 로고
    • Dielectric properties of lung tissue as a function of air content
    • Nopp P, Rapp E, Pfutzner H, Nakesch H, Ruhsam C (1993) Dielectric properties of lung tissue as a function of air content. Phys Med Biol 38:699-716
    • (1993) Phys Med Biol , vol.38 , pp. 699-716
    • Nopp, P.1    Rapp, E.2    Pfutzner, H.3    Nakesch, H.4    Ruhsam, C.5
  • 8
    • 0031844273 scopus 로고    scopus 로고
    • The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs
    • Hickling KG (1998) The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs. Am J Respir Crit Care Med 158:194-202
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 194-202
    • Hickling, K.G.1
  • 9
    • 0021500331 scopus 로고
    • Applied potential tomography
    • Barber DC and Brown BH (1984) Applied potential tomography. J Phys [E] 17:723-733
    • (1984) J Phys [E] , vol.17 , pp. 723-733
    • Barber, D.C.1    Brown, B.H.2
  • 10
    • 0029845456 scopus 로고    scopus 로고
    • Local mechanics of the lung tissue determined by functional EIT
    • Hahn G, Frerichs I, Kleyer M, Hellige G (1996) Local mechanics of the lung tissue determined by functional EIT. Physiol Meas 17 [Suppl 4A]:A159-A166
    • (1996) Physiol Meas , vol.17 , Issue.SUPPL. 4A
    • Hahn, G.1    Frerichs, I.2    Kleyer, M.3    Hellige, G.4
  • 11
    • 0024417871 scopus 로고
    • A computerized respiratory system including test functions of lung and circulation
    • Jansen JRC, Hoorn E, Goudoever J van, Versprille A (1989) A computerized respiratory system including test functions of lung and circulation. J Appl Physiol 67:1687-1691
    • (1989) J Appl Physiol , vol.67 , pp. 1687-1691
    • Jansen, J.R.C.1    Hoorn, E.2    Van Goudoever, J.3    Versprille, A.4
  • 13
    • 0022617227 scopus 로고
    • Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
    • Jansen JR, Versprille A (1986) Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation. Intensive Care Med 12:71-79
    • (1986) Intensive Care Med , vol.12 , pp. 71-79
    • Jansen, J.R.1    Versprille, A.2
  • 15
    • 0025309025 scopus 로고
    • Design and validation of an indicator gas injector for multiple gas washout tests in mechanically ventilated patients
    • Huygen PE, Feenstra BW, Holland WP, Ince C, Stam H, Bruining HA (1990) Design and validation of an indicator gas injector for multiple gas washout tests in mechanically ventilated patients. Crit Care Med 18:754-759
    • (1990) Crit Care Med , vol.18 , pp. 754-759
    • Huygen, P.E.1    Feenstra, B.W.2    Holland, W.P.3    Ince, C.4    Stam, H.5    Bruining, H.A.6
  • 16
    • 0031908102 scopus 로고    scopus 로고
    • A comprehensive equation for the pulmonary pressure-volume curve
    • Venegas JG, Harris RS, Simon BA (1998) A comprehensive equation for the pulmonary pressure-volume curve. J Appl Physiol 84:389-395
    • (1998) J Appl Physiol , vol.84 , pp. 389-395
    • Venegas, J.G.1    Harris, R.S.2    Simon, B.A.3
  • 17
    • 0034095177 scopus 로고    scopus 로고
    • An objective analysis of the pressure-volume curve in the acute respiratory distress syndrome
    • Harris RS, Hess DR, Venegas JG (2000) An objective analysis of the pressure-volume curve in the acute respiratory distress syndrome. Am J Respir Crit Care Med 161:432-439
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 432-439
    • Harris, R.S.1    Hess, D.R.2    Venegas, J.G.3
  • 18
    • 0023080201 scopus 로고
    • Applications of applied potential tomography (APT) in respiratory medicine
    • Harris ND, Suggett AJ, Barber DC, Brown BH (1987) Applications of applied potential tomography (APT) in respiratory medicine. Clin Phys Physiol Meas 8 [Suppl A]:155-165
    • (1987) Clin Phys Physiol Meas , vol.8 , Issue.SUPPL. A , pp. 155-165
    • Harris, N.D.1    Suggett, A.J.2    Barber, D.C.3    Brown, B.H.4
  • 19
    • 0030657934 scopus 로고    scopus 로고
    • Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    • Adler A, Amyot R, Guardo R, Bates JHT, Berhiaume Y (1997) Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 89:1762-1767
    • (1997) J Appl Physiol , vol.89 , pp. 1762-1767
    • Adler, A.1    Amyot, R.2    Guardo, R.3    Bates, J.H.T.4    Berhiaume, Y.5
  • 20
    • 0031686017 scopus 로고    scopus 로고
    • Electrical impedance tomography in monitoring experimental lung injury
    • Frerichs I, Hahn G, Schroder T. Hellige G (1998) Electrical impedance tomography in monitoring experimental lung injury. Intensive Care Med 24:829-836
    • (1998) Intensive Care Med , vol.24 , pp. 829-836
    • Frerichs, I.1    Hahn, G.2    Schroder, T.3    Hellige, G.4
  • 21
    • 0032908593 scopus 로고    scopus 로고
    • Evaluation of electrical impedance tomography in the measurement of PEEP-induced changes in lung volume
    • Kunst PW, de Vries PM, Postmus PE, Bakker J (1999) Evaluation of electrical impedance tomography in the measurement of PEEP-induced changes in lung volume. Chest 115:1102-1106
    • (1999) Chest , vol.115 , pp. 1102-1106
    • Kunst, P.W.1    De Vries, P.M.2    Postmus, P.E.3    Bakker, J.4
  • 22
    • 0034884499 scopus 로고    scopus 로고
    • Non-invasive radiation-free monitoring of regional lung ventilation in critically ill infants
    • Frerichs I, Schiffmann H, Hahn G, Hellige G (2001) Non-invasive radiation-free monitoring of regional lung ventilation in critically ill infants. Intensive Care Med 27:1385-1394
    • (2001) Intensive Care Med , vol.27 , pp. 1385-1394
    • Frerichs, I.1    Schiffmann, H.2    Hahn, G.3    Hellige, G.4
  • 25
    • 66949174349 scopus 로고    scopus 로고
    • Imprecision in lower "inflection point" estimation from static pressure-volume curves in patients at risk for acute respiratory distress syndrome
    • O'Keefe GE, Gentilello LM, Erford S, Maier RV (1998) Imprecision in lower "inflection point" estimation from static pressure-volume curves in patients at risk for acute respiratory distress syndrome. J Trauma 44:1064-1068
    • (1998) J Trauma , vol.44 , pp. 1064-1068
    • O'Keefe, G.E.1    Gentilello, L.M.2    Erford, S.3    Maier, R.V.4
  • 26
    • 0027417772 scopus 로고
    • Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome
    • Gattinoni L, D'Andrea L, Pelosi P, Vitale G, Pesenti A, Fumagalli R (1993) Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome. JAMA 269:2122-127
    • (1993) JAMA , vol.269 , pp. 2122-2127
    • Gattinoni, L.1    D'Andrea, L.2    Pelosi, P.3    Vitale, G.4    Pesenti, A.5    Fumagalli, R.6
  • 28
    • 0035021511 scopus 로고    scopus 로고
    • Optimal mean airway pressure during high-frequency oscillation: Predicted by the pressure-volume curve
    • Goddon S, Fujino Y, Hromi JM, Kacmarek RM (2001) Optimal mean airway pressure during high-frequency oscillation: predicted by the pressure-volume curve. Anesthesiology 94:862-869
    • (2001) Anesthesiology , vol.94 , pp. 862-869
    • Goddon, S.1    Fujino, Y.2    Hromi, J.M.3    Kacmarek, R.M.4
  • 29
    • 0020613773 scopus 로고
    • Static pressure-volume curves and effect of positive end-expiratory pressure on gas exchange in adult respiratory distress syndrome
    • Holzapfel L, Robert D, Perrin F, Blanc PL, Palmier B, Guerin C (1983) Static pressure-volume curves and effect of positive end-expiratory pressure on gas exchange in adult respiratory distress syndrome. Crit Care Med 11:591-597
    • (1983) Crit Care Med , vol.11 , pp. 591-597
    • Holzapfel, L.1    Robert, D.2    Perrin, F.3    Blanc, P.L.4    Palmier, B.5    Guerin, C.6
  • 30
    • 0343893748 scopus 로고    scopus 로고
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • Acute Respiratory Distress Syndrome Network (2000) Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342:1301-1318
    • (2000) N Engl J Med , vol.342 , pp. 1301-1318


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.