메뉴 건너뛰기




Volumn 60, Issue 4, 2006, Pages 401-406

Protective strategies of high-frequency oscillatory ventilation in a rabbit model

Author keywords

[No Author keywords available]

Indexed keywords

LUNG SURFACTANT; MYELOPEROXIDASE;

EID: 33748916413     PISSN: 00313998     EISSN: None     Source Type: Journal    
DOI: 10.1203/01.pdr.0000238248.42925.f4     Document Type: Article
Times cited : (18)

References (27)
  • 1
    • 0034581316 scopus 로고    scopus 로고
    • Mechanical ventilation: Lessons from the ARDSNet trial
    • Slutsky AS, Ranieri VM 2000 Mechanical ventilation: lessons from the ARDSNet trial. Respir Res 1:73-77
    • (2000) Respir Res , vol.1 , pp. 73-77
    • Slutsky, A.S.1    Ranieri, V.M.2
  • 2
    • 0027935397 scopus 로고
    • Understanding the pressure cost of ventilation: Why does high-frequency ventilation work?
    • Venegas JG, Fredberg JJ 1994 Understanding the pressure cost of ventilation: why does high-frequency ventilation work? Crit Care Med 22:S49-S57
    • (1994) Crit Care Med , vol.22
    • Venegas, J.G.1    Fredberg, J.J.2
  • 3
    • 0021340725 scopus 로고
    • Mechanisms of gas transport during ventilation by high-frequency oscillation
    • Chang HK 1984 Mechanisms of gas transport during ventilation by high-frequency oscillation. J Appl Physiol 56:553-563
    • (1984) J Appl Physiol , vol.56 , pp. 553-563
    • Chang, H.K.1
  • 4
    • 0023195229 scopus 로고
    • Tidal volumes required to maintain isocapnia at frequencies from 3 to 30 Hz in the dog
    • Kolton M, McGhee I, Bryan AC 1987 Tidal volumes required to maintain isocapnia at frequencies from 3 to 30 Hz in the dog. Anesth Analg 66:523-528
    • (1987) Anesth Analg , vol.66 , pp. 523-528
    • Kolton, M.1    McGhee, I.2    Bryan, A.C.3
  • 5
    • 14944346876 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation: Lessons from the neonatal/pediatric experience
    • Froese AB, Kinsella JP 2005 High-frequency oscillatory ventilation: lessons from the neonatal/pediatric experience. Crit Care Med 33:S115-S121
    • (2005) Crit Care Med , vol.33
    • Froese, A.B.1    Kinsella, J.P.2
  • 6
    • 0023900655 scopus 로고
    • Lung volume maintenance prevents lung injury during high-frequency oscillatory ventilation in surfactant-deficient rabbits
    • McCulloch PR, Forkert PG, Froese AB 1988 Lung volume maintenance prevents lung injury during high-frequency oscillatory ventilation in surfactant-deficient rabbits. Am Rev Respir Dis 137:1185-1192
    • (1988) Am Rev Respir Dis , vol.137 , pp. 1185-1192
    • McCulloch, P.R.1    Forkert, P.G.2    Froese, A.B.3
  • 7
    • 0018863191 scopus 로고
    • In vivo lung lavage as an experimental model of the respiratory distress syndrome
    • Lachmann B, Robertson B, Vogel J 1980 In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand 24:231-236
    • (1980) Acta Anaesthesiol Scand , vol.24 , pp. 231-236
    • Lachmann, B.1    Robertson, B.2    Vogel, J.3
  • 8
    • 0032880553 scopus 로고    scopus 로고
    • The open lung during small tidal volume ventilation: Concepts of recruitment and "optimal" positive end-expiratory pressure
    • Rimensberger PC, Cox PN, Frndova H, Bryan AC 1999 The open lung during small tidal volume ventilation: concepts of recruitment and "optimal" positive end-expiratory pressure. Crit Care Med 27:1946-1952
    • (1999) Crit Care Med , vol.27 , pp. 1946-1952
    • Rimensberger, P.C.1    Cox, P.N.2    Frndova, H.3    Bryan, A.C.4
  • 9
    • 0033939423 scopus 로고    scopus 로고
    • Lung recruitment and lung volume maintenance: A strategy for improving oxygenation and preventing lung injury during both conventional mechanical ventilation and high-frequency oscillation
    • Rimensberger PC, Pache JC, McKerlie C, Frndova H, Cox PN 2000 Lung recruitment and lung volume maintenance: a strategy for improving oxygenation and preventing lung injury during both conventional mechanical ventilation and high-frequency oscillation. Intensive Care Med 26:745-755
    • (2000) Intensive Care Med , vol.26 , pp. 745-755
    • Rimensberger, P.C.1    Pache, J.C.2    McKerlie, C.3    Frndova, H.4    Cox, P.N.5
  • 12
    • 0347595295 scopus 로고    scopus 로고
    • Complement C5a receptor antagonist attenuates multiple organ injury in a model of ruptured abdominal aortic aneurysm
    • Harkin DW, Romaschin A, Taylor SM, Romaschin A, Rubin BB, Lindsay TF 2004 Complement C5a receptor antagonist attenuates multiple organ injury in a model of ruptured abdominal aortic aneurysm. J Vasc Surg 39:196-206
    • (2004) J Vasc Surg , vol.39 , pp. 196-206
    • Harkin, D.W.1    Romaschin, A.2    Taylor, S.M.3    Romaschin, A.4    Rubin, B.B.5    Lindsay, T.F.6
  • 13
    • 0032855289 scopus 로고    scopus 로고
    • A CD18 monoclonal antibody reduces multiple organ injury in a model of ruptured abdominal aortic aneurysm
    • Boyd AJ, Rubin BB, Walker PM, Romaschin A, Issekutz TB, Lindsay TF 1999 A CD18 monoclonal antibody reduces multiple organ injury in a model of ruptured abdominal aortic aneurysm. Am J Physiol 277:172-182
    • (1999) Am J Physiol , vol.277 , pp. 172-182
    • Boyd, A.J.1    Rubin, B.B.2    Walker, P.M.3    Romaschin, A.4    Issekutz, T.B.5    Lindsay, T.F.6
  • 15
    • 0020550892 scopus 로고
    • Assay method for myeloperoxidase in human polymorphonuclear leukocytes
    • Suzuki K, Ota H, Sasagawa S, Sakatani T, Fujikura T 1983 Assay method for myeloperoxidase in human polymorphonuclear leukocytes. Anal Biochem 132:345-352
    • (1983) Anal Biochem , vol.132 , pp. 345-352
    • Suzuki, K.1    Ota, H.2    Sasagawa, S.3    Sakatani, T.4    Fujikura, T.5
  • 16
    • 0029014821 scopus 로고
    • Acute pulmonary injury in a model of ruptured abdominal aortic aneurysm
    • Lindsay TF, Walker PM, Romaschin A 1995 Acute pulmonary injury in a model of ruptured abdominal aortic aneurysm. J Vasc Surg 22:1-8
    • (1995) J Vasc Surg , vol.22 , pp. 1-8
    • Lindsay, T.F.1    Walker, P.M.2    Romaschin, A.3
  • 17
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG 1977 The measurement of observer agreement for categorical data. Biometrics 33:159-174
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 19
    • 0028031459 scopus 로고
    • Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung
    • Sugiura M, McCulloch PR, Wren S, Dawson RH, Froese AB 1994 Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung. J Appl Physiol 77:1355-1365
    • (1994) J Appl Physiol , vol.77 , pp. 1355-1365
    • Sugiura, M.1    McCulloch, P.R.2    Wren, S.3    Dawson, R.H.4    Froese, A.B.5
  • 20
    • 0034807671 scopus 로고    scopus 로고
    • Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation
    • Imai Y, Nakagawa S, Ito Y, Kawano T, Slutsky AS, Miyasaka K 2001 Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation. J Appl Physiol 91:1836-1844
    • (2001) J Appl Physiol , vol.91 , pp. 1836-1844
    • Imai, Y.1    Nakagawa, S.2    Ito, Y.3    Kawano, T.4    Slutsky, A.S.5    Miyasaka, K.6
  • 21
    • 0031024517 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation with partial liquid ventilation in a model of acute respiratory failure
    • Baden HP, Mellema JD, Bratton SL, O'Rourke PP, Jackson JC 1997 High-frequency oscillatory ventilation with partial liquid ventilation in a model of acute respiratory failure. Crit Care Med 25:299-302
    • (1997) Crit Care Med , vol.25 , pp. 299-302
    • Baden, H.P.1    Mellema, J.D.2    Bratton, S.L.3    O'Rourke, P.P.4    Jackson, J.C.5
  • 22
    • 0035170763 scopus 로고    scopus 로고
    • Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury
    • Rotta AT, Gunnarsson B, Fuhrman BP, Hernan LJ, Steinhorn DM 2001 Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury. Crit Care Med 29:2176-2184
    • (2001) Crit Care Med , vol.29 , pp. 2176-2184
    • Rotta, A.T.1    Gunnarsson, B.2    Fuhrman, B.P.3    Hernan, L.J.4    Steinhorn, D.M.5
  • 23
    • 0025040482 scopus 로고
    • Proximal, tracheal, and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model
    • Gerstmann DR, Fouke JM, Winter DC, Taylor AF, deLemos RA 1990 Proximal, tracheal, and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model. Pediatr Res 28:367-373
    • (1990) Pediatr Res , vol.28 , pp. 367-373
    • Gerstmann, D.R.1    Fouke, J.M.2    Winter, D.C.3    Taylor, A.F.4    DeLemos, R.A.5
  • 24
    • 0033695269 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation: Effects on lung function, mechanics, and airway cytokines in the immature baboon model for neonatal chronic lung disease
    • Yoder BA, Siler-Khodr T, Winter VT, Coalson JJ 2000 High-frequency oscillatory ventilation: effects on lung function, mechanics, and airway cytokines in the immature baboon model for neonatal chronic lung disease. Am J Respir Crit Care Med 162:1867-1876
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 1867-1876
    • Yoder, B.A.1    Siler-Khodr, T.2    Winter, V.T.3    Coalson, J.J.4
  • 25
    • 0035880176 scopus 로고    scopus 로고
    • Effects of high-frequency oscillation on endogenous surfactant in an acute lung injury model
    • Kerr CL, Veldhuizen RA, Lewis JF 2001 Effects of high-frequency oscillation on endogenous surfactant in an acute lung injury model. Am J Respir Crit Care Med 164:237-242
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 237-242
    • Kerr, C.L.1    Veldhuizen, R.A.2    Lewis, J.F.3
  • 26
    • 33645981736 scopus 로고    scopus 로고
    • High-frequency oscillation ventilation compared to conventional mechanical ventilation plus exogenous surfactant replacement in rabbits
    • Rio J
    • Piva J, Chatrkaw P, Choong K, Frndova H, Cox P 2000 High-frequency oscillation ventilation compared to conventional mechanical ventilation plus exogenous surfactant replacement in rabbits. J Pediatr (Rio J) 76:349-356
    • (2000) J Pediatr , vol.76 , pp. 349-356
    • Piva, J.1    Chatrkaw, P.2    Choong, K.3    Frndova, H.4    Cox, P.5
  • 27
    • 0031746090 scopus 로고    scopus 로고
    • Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
    • Hatcher D, Watanabe H, Ashbury T, Vincent S, Fisher J, Froese A 1998 Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators. Crit Care Med 26:1081-1088
    • (1998) Crit Care Med , vol.26 , pp. 1081-1088
    • Hatcher, D.1    Watanabe, H.2    Ashbury, T.3    Vincent, S.4    Fisher, J.5    Froese, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.