메뉴 건너뛰기




Volumn 26, Issue 1, 2011, Pages

Corrosion at the Stem-Sleeve Interface of a Modular Titanium Alloy Femoral Component as a Reason for Impaired Disengagement

Author keywords

Corrosion; Modular femoral component; Titanium alloy; Total hip replacement

Indexed keywords

TITANIUM;

EID: 78650033929     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2009.10.018     Document Type: Article
Times cited : (42)

References (15)
  • 1
    • 25144487369 scopus 로고    scopus 로고
    • The S-ROM stem: versatility of stem/sleeve combinations and head options
    • Buly R. The S-ROM stem: versatility of stem/sleeve combinations and head options. Orthopedics 2005, 28(Suppl.):S1025.
    • (2005) Orthopedics , vol.28 , Issue.SUPPL.
    • Buly, R.1
  • 2
    • 25144474180 scopus 로고    scopus 로고
    • The S-ROM cementless femoral stem: history and literature review
    • Spitzer A.I. The S-ROM cementless femoral stem: history and literature review. Orthopedics 2005, 28(Suppl.):S1117.
    • (2005) Orthopedics , vol.28 , Issue.SUPPL.
    • Spitzer, A.I.1
  • 3
    • 0032760936 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results
    • Christie M.J., DeBoer D.K., Trick L.W., et al. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results. J Bone Joint Surg 1999, 81-A:1707.
    • (1999) J Bone Joint Surg , pp. 1707
    • Christie, M.J.1    DeBoer, D.K.2    Trick, L.W.3
  • 4
    • 0035655869 scopus 로고    scopus 로고
    • Primary cementless total hip arthroplasty using a modular femoral component. A minimum 6-year follow-up
    • Tanzer M., Chan S., Brooks C.E., et al. Primary cementless total hip arthroplasty using a modular femoral component. A minimum 6-year follow-up. J Arthroplasty 2001, 16(Suppl. 1):64.
    • (2001) J Arthroplasty , vol.16 , Issue.SUPPL. 1 , pp. 64
    • Tanzer, M.1    Chan, S.2    Brooks, C.E.3
  • 5
    • 33745009243 scopus 로고    scopus 로고
    • The role of modularity in primary total hip arthroplasty
    • Cameron H.U., Keppler L., McTighe T. The role of modularity in primary total hip arthroplasty. J Arthroplasty 2006, 21(Suppl. 1):89.
    • (2006) J Arthroplasty , vol.21 , Issue.SUPPL. 1 , pp. 89
    • Cameron, H.U.1    Keppler, L.2    McTighe, T.3
  • 6
    • 0028845168 scopus 로고
    • Revision total hip replacement using S-ROM femoral component
    • Chandler H.P., Ayres D.K., Tan R.C., et al. Revision total hip replacement using S-ROM femoral component. Clin Orthop Relat Res 1995, 319:130.
    • (1995) Clin Orthop Relat Res , vol.319 , pp. 130
    • Chandler, H.P.1    Ayres, D.K.2    Tan, R.C.3
  • 7
    • 0031020719 scopus 로고    scopus 로고
    • Cementless femoral revision arthroplasty. 2- to 5-year results with a modular titanium alloy stem
    • Smith J.A., Dunn H.K., Manaster B.J. Cementless femoral revision arthroplasty. 2- to 5-year results with a modular titanium alloy stem. J Arthroplasty 1997, 12:194.
    • (1997) J Arthroplasty , vol.12 , pp. 194
    • Smith, J.A.1    Dunn, H.K.2    Manaster, B.J.3
  • 8
    • 33644770219 scopus 로고    scopus 로고
    • Clinical and radiographic assessment of a modular cementless ingrowth femoral stem system for revision hip arthroplasty
    • Walter W.L., Walter W.K., Zicat B. Clinical and radiographic assessment of a modular cementless ingrowth femoral stem system for revision hip arthroplasty. J Arthroplasty 2006, 21:172.
    • (2006) J Arthroplasty , vol.21 , pp. 172
    • Walter, W.L.1    Walter, W.K.2    Zicat, B.3
  • 9
    • 0028501854 scopus 로고
    • Fatigue behavior of a titanium femoral hip prosthesis with proximal sleeve-stem modularity
    • Krygier J.J., Dujovne A.R., Bobyn J.D. Fatigue behavior of a titanium femoral hip prosthesis with proximal sleeve-stem modularity. J Appl Biomater 1994, 5:195.
    • (1994) J Appl Biomater , vol.5 , pp. 195
    • Krygier, J.J.1    Dujovne, A.R.2    Bobyn, J.D.3
  • 11
    • 0027155027 scopus 로고
    • Torsional resistance and wear of a modular sleeve-stem hip system
    • Cook S.D., Manley M.T., Kester M.A., et al. Torsional resistance and wear of a modular sleeve-stem hip system. Clin Mater 1993, 12:153.
    • (1993) Clin Mater , vol.12 , pp. 153
    • Cook, S.D.1    Manley, M.T.2    Kester, M.A.3
  • 12
  • 13
    • 0036339423 scopus 로고    scopus 로고
    • A multicenter retrieval study of the taper interfaces of modular hip prostheses
    • Goldberg J.R., Gilbert J.L., Jacobs J.J., et al. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res 2002, 401:149.
    • (2002) Clin Orthop Relat Res , vol.401 , pp. 149
    • Goldberg, J.R.1    Gilbert, J.L.2    Jacobs, J.J.3
  • 14
  • 15
    • 0028054956 scopus 로고
    • Wear and corrosion of modular interfaces in total hip replacements
    • Cook S.D., Barrack R.L., Baffes G.C., et al. Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop Relat Res 1994, 298:80.
    • (1994) Clin Orthop Relat Res , vol.298 , pp. 80
    • Cook, S.D.1    Barrack, R.L.2    Baffes, G.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.