1
-
-
77949866490
-
Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment
-
doi:10.1021/ac100061k
-
Mieth M, Schubert JK, Groger T, Sabel B, Kischkel S, Fuchs P, Hein D, Zimmermann R, Miekisch W (2010) Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment. Anal Chem 82: 2541-2551. doi: 10. 1021/ac100061k.
-
(2010)
Anal Chem
, vol.82
, pp. 2541-2551
-
-
Mieth, M.1
Schubert, J.K.2
Groger, T.3
Sabel, B.4
Kischkel, S.5
Fuchs, P.6
Hein, D.7
Zimmermann, R.8
Miekisch, W.9
-
2
-
-
72849106041
-
Peak assignment in multi-capillary column - ion mobility spectrometry using comparative studies with gas chromatography - mass spectrometry for exhalred breath analysis
-
doi:10.1007/s00216-009-3168-z
-
Jünger M, Bödeker B, Baumbach JI (2010) Peak assignment in multi-capillary column - ion mobility spectrometry using comparative studies with gas chromatography - mass spectrometry for exhalred breath analysis. Anal Bioanal Chem 396: 471-482. doi: 10. 1007/s00216-009-3168-z.
-
(2010)
Anal Bioanal Chem
, vol.396
, pp. 471-482
-
-
Jünger, M.1
Bödeker, B.2
Baumbach, J.I.3
-
3
-
-
69749091957
-
Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study
-
doi:10.1136/thx.2008.099465
-
Westhoff M, Litterst P, Freitag L, Urfer W, Bader S, Baumbach JI (2009) Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study. Thorax 64: 744-748. doi: 10. 1136/thx. 2008. 099465.
-
(2009)
Thorax
, vol.64
, pp. 744-748
-
-
Westhoff, M.1
Litterst, P.2
Freitag, L.3
Urfer, W.4
Bader, S.5
Baumbach, J.I.6
-
4
-
-
67649666959
-
Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry
-
Buszewski B, Ulanowska A, Ligor T, Denderz N, Amann A (2009) Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry. Biomed Chromatogr 23: 551-556.
-
(2009)
Biomed Chromatogr
, vol.23
, pp. 551-556
-
-
Buszewski, B.1
Ulanowska, A.2
Ligor, T.3
Denderz, N.4
Amann, A.5
-
5
-
-
62449177156
-
The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS
-
Ligor T, Ligor M, Amann A, Ager C, Bachler M, Dzien A, Buszewski B (2008) The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS. J Breath Res 2: 046006.
-
(2008)
J Breath Res
, vol.2
, pp. 046006
-
-
Ligor, T.1
Ligor, M.2
Amann, A.3
Ager, C.4
Bachler, M.5
Dzien, A.6
Buszewski, B.7
-
6
-
-
84883603546
-
Compounds enhanced in a mass spectrometric profile of smokers' exhaled breath versus non-smokers as determined in a pilot study using PTR-MS
-
Kushch I et al (2008) Compounds enhanced in a mass spectrometric profile of smokers' exhaled breath versus non-smokers as determined in a pilot study using PTR-MS. J Breath Res 2: 026002.
-
(2008)
J Breath Res
, vol.2
, pp. 026002
-
-
Kushch, I.1
-
7
-
-
33847788491
-
Breath analysis: the approach towards clinical applications
-
Amann A, Spanel P, Smith D (2007) Breath analysis: the approach towards clinical applications. Mini-Rev Med Chem 7: 115-129.
-
(2007)
Mini-Rev Med Chem
, vol.7
, pp. 115-129
-
-
Amann, A.1
Spanel, P.2
Smith, D.3
-
8
-
-
77952934972
-
Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsules
-
doi: 10. 1088/1752-7155/4/2/026006
-
Beauchamp J, Kirsch F, Buettner A (2010) Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsules. J Breath Res 4: No pp. given, doi: 10. 1088/1752-7155/4/2/026006.
-
(2010)
J Breath Res
, vol.4
-
-
Beauchamp, J.1
Kirsch, F.2
Buettner, A.3
-
9
-
-
68149126539
-
On-line breath analysis with PTR-TOF
-
Herbig J, Mueller M, Schallhart S, Titzmann T, Graus M, Hansel A (2009) On-line breath analysis with PTR-TOF. J Breath Res 3: 027004.
-
(2009)
J Breath Res
, vol.3
, pp. 027004
-
-
Herbig, J.1
Mueller, M.2
Schallhart, S.3
Titzmann, T.4
Graus, M.5
Hansel, A.6
-
10
-
-
0002939202
-
Proton Transfer Reaction Mass Spectrometry (PTR-MS) propanol in human breath
-
Warneke C, Kuczynski J, Hansel A (1996) Proton Transfer Reaction Mass Spectrometry (PTR-MS) propanol in human breath. Int J Mass Spectrom Ion Proc 154: 61-70.
-
(1996)
Int J Mass Spectrom Ion Proc
, vol.154
, pp. 61-70
-
-
Warneke, C.1
Kuczynski, J.2
Hansel, A.3
-
11
-
-
26744446019
-
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
-
Hansel A, Jordan A, Holzinger R (1995) Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level. Int J Mass Spectrom Ion Process 149: 609-619.
-
(1995)
Int J Mass Spectrom Ion Process
, vol.149
, pp. 609-619
-
-
Hansel, A.1
Jordan, A.2
Holzinger, R.3
-
12
-
-
76249132107
-
Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS
-
Smith D, Spanel P, Enderby B, Lenney W, Turner C, Davies SJ (2010) Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS. J Breath Res 4: 017101/017101-017101/017107.
-
(2010)
J Breath Res
, vol.4
, pp. 017101-017107
-
-
Smith, D.1
Spanel, P.2
Enderby, B.3
Lenney, W.4
Turner, C.5
Davies, S.J.6
-
13
-
-
68149183618
-
In vitro SIFT-MS validation of a breath fractionating device using a model VOC and ventilation system
-
Seeley MJ, Hu W-P, Scotter JM, Storer MK, Shaw GM (2009) In vitro SIFT-MS validation of a breath fractionating device using a model VOC and ventilation system. J Breath Res 3(1): 016001.
-
(2009)
J Breath Res
, vol.3
, Issue.1
, pp. 016001
-
-
Seeley, M.J.1
Hu, W.-P.2
Scotter, J.M.3
Storer, M.K.4
Shaw, G.M.5
-
14
-
-
62349121500
-
Quantification of trace levels of the potential cancer biomarkers formaldehyde, acetaldehyde and propanol in breath by SIFT-MS
-
Spanel P, Smith D (2008) Quantification of trace levels of the potential cancer biomarkers formaldehyde, acetaldehyde and propanol in breath by SIFT-MS. J Breath Res 2: 046003/046001-046003/046010.
-
(2008)
J Breath Res
, vol.2
, pp. 046001-046010
-
-
Spanel, P.1
Smith, D.2
-
15
-
-
84974678877
-
The concentration distributions of some metabolites in the exhaled breath of young adults
-
Spanel P, Dryahina K, Smith D (2007) The concentration distributions of some metabolites in the exhaled breath of young adults. J Breath Res 1: 1-8.
-
(2007)
J Breath Res
, vol.1
, pp. 1-8
-
-
Spanel, P.1
Dryahina, K.2
Smith, D.3
-
16
-
-
84974690927
-
Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions
-
Smith D, Turner C, Spanel P (2007) Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions. J Breath Res 1: R1-R12.
-
(2007)
J Breath Res
, vol.1
-
-
Smith, D.1
Turner, C.2
Spanel, P.3
-
17
-
-
84967579140
-
Analysis of breath using SIFT-MS: A comparison of the breath composition of healthy volunteers and seriously-ill ICU patients
-
[Presentations Conf. "Breath Gas Anal. Med. Diagn."] FIELD Full Journal Title: Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring, [Based on Presentations at the Conference "Breath Gas Analysis for Medical Diagnostics"], Dornbirn, Austria, Sept. 23-26, 2004
-
Turner C, Welch S, Bellingan G, Singer M, Spanel P, Smith D (2005) Analysis of breath using SIFT-MS: A comparison of the breath composition of healthy volunteers and seriously-ill ICU patients. Breath Anal. Clin. Diagn. Ther. Monit., [Presentations Conf. "Breath Gas Anal. Med. Diagn."] FIELD Full Journal Title: Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring, [Based on Presentations at the Conference "Breath Gas Analysis for Medical Diagnostics"], Dornbirn, Austria, Sept. 23-26, 2004, 317-326.
-
(2005)
Breath Anal. Clin. Diagn. Ther. Monit.
, pp. 317-326
-
-
Turner, C.1
Welch, S.2
Bellingan, G.3
Singer, M.4
Spanel, P.5
Smith, D.6
-
18
-
-
0035944248
-
Concurrent use of H3O+, NO+, and O2+ precursor ions for the detection and quantification of diverse trace gases in the presence of air and breath by selected ion-flow tube mass spectrometry
-
Smith D, Diskin AM, Ji Y, Spanel P (2001) Concurrent use of H3O+, NO+, and O2+ precursor ions for the detection and quantification of diverse trace gases in the presence of air and breath by selected ion-flow tube mass spectrometry. Int J Mass Spectrom 209: 81-97.
-
(2001)
Int J Mass Spectrom
, vol.209
, pp. 81-97
-
-
Smith, D.1
Diskin, A.M.2
Ji, Y.3
Spanel, P.4
-
19
-
-
77955981383
-
Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry
-
doi:10.1007/s00216-010-3798-1
-
Perl T, Bödecker B, Jünger M, Nolte J, Vautz W (2010) Alignment of retention time obtained from multicapillary column gas chromatography used for VOC analysis with ion mobility spectrometry. Anal Bioanal Chem 397: 2385-2394. doi: 10. 1007/s00216-010-3798-1.
-
(2010)
Anal Bioanal Chem
, vol.397
, pp. 2385-2394
-
-
Perl, T.1
Bödecker, B.2
Jünger, M.3
Nolte, J.4
Vautz, W.5
-
20
-
-
73949096027
-
Breath analysis-performance and potential of ion mobility spectrometry
-
doi:036010.031088/031752-037155/036003/036003/036004
-
Vautz W, Nolte J, Fobbe R, Baumbach JI (2009) Breath analysis-performance and potential of ion mobility spectrometry. J Breath Res 3: 036004. doi: 036010. 031088/031752-037155/036003/036003/036004.
-
(2009)
J Breath Res
, vol.3
, pp. 036004
-
-
Vautz, W.1
Nolte, J.2
Fobbe, R.3
Baumbach, J.I.4
-
21
-
-
72349084045
-
MCC/IMS signals in human breath related to sarcoidosis-results of a feasibility study using an automated peak finding procedure
-
Bunkowski A, Boedeker B, Bader S, Westhoff M, Litterst P, Baumbach JI (2009) MCC/IMS signals in human breath related to sarcoidosis-results of a feasibility study using an automated peak finding procedure. J Breath Res 3: 046001/046001-046001/046010.
-
(2009)
J Breath Res
, vol.3
, pp. 046001-046010
-
-
Bunkowski, A.1
Boedeker, B.2
Bader, S.3
Westhoff, M.4
Litterst, P.5
Baumbach, J.I.6
-
22
-
-
40449107205
-
Ion mobility spectrometry in the diagnosis of Sarcoidosis: results of a feasibility study
-
Westhoff M, Litterst P, Freitag L, Baumbach JI (2007) Ion mobility spectrometry in the diagnosis of Sarcoidosis: results of a feasibility study. J Physiol Pharmacol 58: 739-751.
-
(2007)
J Physiol Pharmacol
, vol.58
, pp. 739-751
-
-
Westhoff, M.1
Litterst, P.2
Freitag, L.3
Baumbach, J.I.4
-
23
-
-
33846356443
-
Ion mobility spectrometry to detect lung cancer and airway infections
-
Baumbach JI, Westhoff M (2006) Ion mobility spectrometry to detect lung cancer and airway infections. Spectrosc Eur 18: 22-27.
-
(2006)
Spectrosc Eur
, vol.18
, pp. 22-27
-
-
Baumbach, J.I.1
Westhoff, M.2
-
24
-
-
33644690314
-
Process analysis using ion mobility spectrometry
-
Baumbach JI (2006) Process analysis using ion mobility spectrometry. Anal Bioanal Chem 384: 1059-1070.
-
(2006)
Anal Bioanal Chem
, vol.384
, pp. 1059-1070
-
-
Baumbach, J.I.1
-
25
-
-
22044456844
-
Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers
-
Ruzsanyi V, Baumbach JI, Sielemann S, Litterst P, Westhoff M, Freitag L (2005) Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers. J Chromatogr A 1084: 145-151.
-
(2005)
J Chromatogr A
, vol.1084
, pp. 145-151
-
-
Ruzsanyi, V.1
Baumbach, J.I.2
Sielemann, S.3
Litterst, P.4
Westhoff, M.5
Freitag, L.6
-
26
-
-
76749130199
-
Non-invasive metabolomic analysis of breath using differential mobility spectrometry in patients with chronic obstructive pulmonary disease and healthy smokers
-
doi:10.1039/b916374c
-
Basanta M, Jarvis RM, Xu Y, Blackburn G, Tal-Singer R, Woodcock A, Singh D, Goodacre R, Thomas CLP, Fowler SJ (2010) Non-invasive metabolomic analysis of breath using differential mobility spectrometry in patients with chronic obstructive pulmonary disease and healthy smokers. Analyst 135: 315-320. doi: 10. 1039/b916374c.
-
(2010)
Analyst
, vol.135
, pp. 315-320
-
-
Basanta, M.1
Jarvis, R.M.2
Xu, Y.3
Blackburn, G.4
Tal-Singer, R.5
Woodcock, A.6
Singh, D.7
Goodacre, R.8
Thomas, C.L.P.9
Fowler, S.J.10
-
27
-
-
33846538621
-
An adaptive breath sampler for use with human subjects with an impaired respiratory function
-
Basanta M, Koimtzis T, Singh D, Wilson I, Thomas CLP (2007) An adaptive breath sampler for use with human subjects with an impaired respiratory function. Analyst 132: 153-163.
-
(2007)
Analyst
, vol.132
, pp. 153-163
-
-
Basanta, M.1
Koimtzis, T.2
Singh, D.3
Wilson, I.4
Thomas, C.L.P.5
-
28
-
-
67650006855
-
Sampling and analysis of exhaled breath on human subjects with thermal desorption gas chromatography - differential mobility spectrometry
-
Basanta M, Koimtzis T, Thomas CLP (2006) Sampling and analysis of exhaled breath on human subjects with thermal desorption gas chromatography - differential mobility spectrometry. Int J Ion Mobility Spectrom 9: 45-49.
-
(2006)
Int J Ion Mobility Spectrom
, vol.9
, pp. 45-49
-
-
Basanta, M.1
Koimtzis, T.2
Thomas, C.L.P.3
-
29
-
-
69249106891
-
Exhaled biomarkers in lung cancer
-
doi:10.1183/09031936.00142508
-
Horvath I, Lazar Z, Gyulai N, Kollai M, Losonczy G (2009) Exhaled biomarkers in lung cancer. Eur Respir J 34: 261-275. doi: 10. 1183/09031936. 00142508.
-
(2009)
Eur Respir J
, vol.34
, pp. 261-275
-
-
Horvath, I.1
Lazar, Z.2
Gyulai, N.3
Kollai, M.4
Losonczy, G.5
-
30
-
-
63249102023
-
An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD
-
doi:10.1016/j.lungcan.2008.08.008
-
Dragonieri S, Annema JT, Schot R, van der Schee MPC, Spanevello A, Carratu P, Resta O, Rabe KF, Sterk PJ (2009) An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer 64: 166-170. doi: 10. 1016/j. lungcan. 2008. 08. 008.
-
(2009)
Lung Cancer
, vol.64
, pp. 166-170
-
-
Dragonieri, S.1
Annema, J.T.2
Schot, R.3
van der Schee, M.P.C.4
Spanevello, A.5
Carratu, P.6
Resta, O.7
Rabe, K.F.8
Sterk, P.J.9
-
31
-
-
76349110542
-
An electronic nose in the discrimination of breath from smokers and non-smokers: a model for toxin exposure
-
Cheng ZJ, Warwick G, Yates DH, Thomas PS (2009) An electronic nose in the discrimination of breath from smokers and non-smokers: a model for toxin exposure. J Breath Res 3: 036003/036001-036003/036005.
-
(2009)
J Breath Res
, vol.3
, pp. 036001-036005
-
-
Cheng, Z.J.1
Warwick, G.2
Yates, D.H.3
Thomas, P.S.4
-
32
-
-
35148827504
-
An electronic nose in the discrimination of patients with asthma and controls
-
doi:10.1016/j.jaci.2007.05.043
-
Dragonieri S et al (2007) An electronic nose in the discrimination of patients with asthma and controls. J Allergy Clin Immunol 120: 856-862. doi: 10. 1016/j. jaci. 2007. 05. 043.
-
(2007)
J Allergy Clin Immunol
, vol.120
, pp. 856-862
-
-
Dragonieri, S.1
-
33
-
-
33749016240
-
Current status of clinical breath analysis
-
Risby TH, Solga SF (2006) Current status of clinical breath analysis. Appl Phys B Lasers Opt 85: 421-426.
-
(2006)
Appl Phys B Lasers Opt
, vol.85
, pp. 421-426
-
-
Risby, T.H.1
Solga, S.F.2
-
34
-
-
82455191488
-
History, technical and regulatory aspects of exhaled nitric oxide
-
Silkoff P (2008) History, technical and regulatory aspects of exhaled nitric oxide. J Breath Res 2: 037001/037001-037001/037008.
-
(2008)
J Breath Res
, vol.2
, pp. 037001-037008
-
-
Silkoff, P.1
-
35
-
-
67649221883
-
Nanotube-based sensor arrays for clinical breath analysis
-
Gelperin A, Johnson ATC (2008) Nanotube-based sensor arrays for clinical breath analysis. J Breath Res 2: 037015/037011-037015/037016.
-
(2008)
J Breath Res
, vol.2
, pp. 037011-037016
-
-
Gelperin, A.1
Johnson, A.T.C.2
-
36
-
-
84883601307
-
The characteristics of novel low-cost sensors for volatile biomarker detection
-
de Lacy Costello BPJ, Ewen RJ, Ratcliffe NM, Richards M (2008) The characteristics of novel low-cost sensors for volatile biomarker detection. J Breath Res 2: 037017/037011-037017/037016.
-
(2008)
J Breath Res
, vol.2
, pp. 037011-037016
-
-
de Lacy Costello, B.P.J.1
Ewen, R.J.2
Ratcliffe, N.M.3
Richards, M.4
-
37
-
-
84883603045
-
A sensor system for monitoring the simple gases hydrogen, carbon monoxide, hydrogen sulfide, ammonia and ethanol in exhaled breath
-
de Lacy Costello BPJ, Ewen RJ, Ratcliffe NM (2008) A sensor system for monitoring the simple gases hydrogen, carbon monoxide, hydrogen sulfide, ammonia and ethanol in exhaled breath. J Breath Res 2: 037011/037011-037011/037019.
-
(2008)
J Breath Res
, vol.2
, pp. 037011-037019
-
-
de Lacy Costello, B.P.J.1
Ewen, R.J.2
Ratcliffe, N.M.3
-
38
-
-
84874880856
-
An analysis of volatiles in the headspace of the faeces of neonates
-
De Lacy Costello B, Ewen R, Ewer AK, Garner CE, Probert CSJ, Ratcliffe NM, Smith S (2008) An analysis of volatiles in the headspace of the faeces of neonates. J Breath Res 2: 037023/037021-037023/037028.
-
(2008)
J Breath Res
, vol.2
, pp. 037021-037028
-
-
de Lacy Costello, B.1
Ewen, R.2
Ewer, A.K.3
Garner, C.E.4
Probert, C.S.J.5
Ratcliffe, N.M.6
Smith, S.7
-
39
-
-
34447298617
-
Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array
-
doi:10.1136/thx.2006.072892
-
Mazzone PJ, Hammel J, Dweik R, Na J, Czich C, Laskowski D, Mekhail T (2007) Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array. Thorax 62: 565-568. doi: 10. 1136/thx. 2006. 072892.
-
(2007)
Thorax
, vol.62
, pp. 565-568
-
-
Mazzone, P.J.1
Hammel, J.2
Dweik, R.3
Na, J.4
Czich, C.5
Laskowski, D.6
Mekhail, T.7
-
40
-
-
33750211186
-
Measurement of ammonia in human breath with a liquid-film conductivity sensor
-
Toda K, Li J, Dasgupta Purnendu K (2006) Measurement of ammonia in human breath with a liquid-film conductivity sensor. Anal Chem 78: 7284-7291.
-
(2006)
Anal Chem
, vol.78
, pp. 7284-7291
-
-
Toda, K.1
Li, J.2
Dasgupta Purnendu, K.3
-
41
-
-
84967367152
-
-
[Based on Presentations at the Conference "Breath Gas Analysis for Medical Diagnostics"], Dornbirn, Austria, Sept. 23-26, 2004 eds A. Anmann & D. Smith, (World Scientific)
-
Baumbach JI, Vautz W, Ruzsanyi V, Freitag L (2005) in Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring [Based on Presentations at the Conference "Breath Gas Analysis for Medical Diagnostics"], Dornbirn, Austria, Sept. 23-26, 2004 eds A. Anmann & D. Smith 53-66 (World Scientific).
-
(2005)
Breath Analysis for Clinical Diagnosis and Therapeutic Monitoring
, pp. 53-66
-
-
Baumbach, J.I.1
Vautz, W.2
Ruzsanyi, V.3
Freitag, L.4
-
42
-
-
0030243562
-
A comparison of cryofocusing injectors for gas sampling and analysis in fast GC
-
Borgerding AJ, Wilkerson CW (1996) A comparison of cryofocusing injectors for gas sampling and analysis in fast GC. Anal Chem 68: 2874-2878.
-
(1996)
Anal Chem
, vol.68
, pp. 2874-2878
-
-
Borgerding, A.J.1
Wilkerson, C.W.2
-
43
-
-
57649093650
-
On-line digestion system for protein characterization and proteome analysis
-
doi:10.1021/ac800927v
-
Lopez-Ferrer D et al (2008) On-line digestion system for protein characterization and proteome analysis. Anal Chem 80: 8930-8936. doi: 10. 1021/ac800927v.
-
(2008)
Anal Chem
, vol.80
, pp. 8930-8936
-
-
Lopez-Ferrer, D.1
-
44
-
-
85008025118
-
Construction and evaluation of a versatile CO2 controlled breath collection device
-
doi:10.1109/jsen.2009.2035757
-
Miekisch W, Hengstenberg A, Kischkel S, Beckmann U, Mieth M, Schubert JK (2010) Construction and evaluation of a versatile CO2 controlled breath collection device. IEEE Sens J 10: 211-215. doi: 10. 1109/jsen. 2009. 2035757.
-
(2010)
IEEE Sens J
, vol.10
, pp. 211-215
-
-
Miekisch, W.1
Hengstenberg, A.2
Kischkel, S.3
Beckmann, U.4
Mieth, M.5
Schubert, J.K.6
-
45
-
-
62349108351
-
On the use of Tedlar bags for breath-gas sampling and analysis
-
Beauchamp J, Herbig J, Gutmann R, Hansel A (2008) On the use of Tedlar bags for breath-gas sampling and analysis. J Breath Res 2: 046001/046001-046001/046019.
-
(2008)
J Breath Res
, vol.2
, pp. 046001-046019
-
-
Beauchamp, J.1
Herbig, J.2
Gutmann, R.3
Hansel, A.4
-
46
-
-
0037139889
-
Determination of volatile organic compounds (VOCs) using Tedlar bag/solid-phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) in ambient and workplace air
-
Lee JH, Hwang SM, Lee DW, Heo GS (2002) Determination of volatile organic compounds (VOCs) using Tedlar bag/solid-phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) in ambient and workplace air. Bull Korean Chem Soc 23: 488-496.
-
(2002)
Bull Korean Chem Soc
, vol.23
, pp. 488-496
-
-
Lee, J.H.1
Hwang, S.M.2
Lee, D.W.3
Heo, G.S.4
-
47
-
-
3042799323
-
Tedlar bag sampling technique for vertical profiling of carbon dioxide through the atmospheric boundary layer with high precision and accuracy
-
Schulz K, Jensen ML, Balsley BB, Davis K, Birks JW (2004) Tedlar bag sampling technique for vertical profiling of carbon dioxide through the atmospheric boundary layer with high precision and accuracy. Environ Sci Technol 38: 3683-3688.
-
(2004)
Environ Sci Technol
, vol.38
, pp. 3683-3688
-
-
Schulz, K.1
Jensen, M.L.2
Balsley, B.B.3
Davis, K.4
Birks, J.W.5
-
48
-
-
34247487094
-
The suitability of Tedlar bags for breath sampling in medical diagnostic research
-
doi:10.1088/0967-3334/28/1/007
-
Steeghs MML, Cristescu SM, Harren FJM (2007) The suitability of Tedlar bags for breath sampling in medical diagnostic research. Physiol Meas 28: 73-84. doi: 10. 1088/0967-3334/28/1/007.
-
(2007)
Physiol Meas
, vol.28
, pp. 73-84
-
-
Steeghs, M.M.L.1
Cristescu, S.M.2
Harren, F.J.M.3
-
49
-
-
70449378196
-
Noninvasive detection of lung cancer by analysis of exhaled breath
-
doi: 10. 1186/1471-2407-9-348
-
Bajtarevic A et al (2009) Noninvasive detection of lung cancer by analysis of exhaled breath. BMC Cancer 9: doi: 10. 1186/1471-2407-9-348.
-
(2009)
BMC Cancer
, vol.9
-
-
Bajtarevic, A.1
-
50
-
-
4544255985
-
Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
-
doi:10.1016/j.jchromb.2004.08.013
-
Deng CH, Zhang J, Yu XF, Zhang W, Zhang XM (2004) Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. J Chromatogr B 810: 269-275. doi: 10. 1016/j. jchromb. 2004. 08. 013.
-
(2004)
J Chromatogr B
, vol.810
, pp. 269-275
-
-
Deng, C.H.1
Zhang, J.2
Yu, X.F.3
Zhang, W.4
Zhang, X.M.5
-
51
-
-
67649158483
-
Determination of volatile organic compounds in exhaled breath of patients with lung cancer using solid phase microextraction and gas chromatography mass spectrometry
-
doi:10.1515/cclm.2009.133
-
Ligor M et al (2009) Determination of volatile organic compounds in exhaled breath of patients with lung cancer using solid phase microextraction and gas chromatography mass spectrometry. Clin Chem Lab Med 47: 550-560. doi: 10. 1515/cclm. 2009. 133.
-
(2009)
Clin Chem Lab Med
, vol.47
, pp. 550-560
-
-
Ligor, M.1
-
52
-
-
0020740091
-
Breath analysis by atmospheric pressure ionization mass spectrometry
-
Benoit MF, Davidson WR, Lovett AM, Nacson S, Ngo A (1983) Breath analysis by atmospheric pressure ionization mass spectrometry. Anal Chem 55: 805-807.
-
(1983)
Anal Chem
, vol.55
, pp. 805-807
-
-
Benoit, M.F.1
Davidson, W.R.2
Lovett, A.M.3
Nacson, S.4
Ngo, A.5
-
53
-
-
68149084598
-
Investigations on the variability of breath gas sampling using PTR-MS
-
Thekedar B, Szymczak W, Hoellriegl V, Hoeschen C, Oeh U (2009) Investigations on the variability of breath gas sampling using PTR-MS. J Breath Res 3: 027007/027001-027007/027011.
-
(2009)
J Breath Res
, vol.3
, pp. 027001-027011
-
-
Thekedar, B.1
Szymczak, W.2
Hoellriegl, V.3
Hoeschen, C.4
Oeh, U.5
-
54
-
-
67650032115
-
Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath
-
Baumbach JI (2009) Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath. J Breath Res 3: 1-16.
-
(2009)
J Breath Res
, vol.3
, pp. 1-16
-
-
Baumbach, J.I.1
-
55
-
-
70350236254
-
Analytical description of IMS-signals
-
doi:10.1007/s12127-009-0024-y
-
Bödeker B, Baumbach JI (2009) Analytical description of IMS-signals. Int J Ion Mobility Spectrom 12: 103-108. doi: 10. 1007/s12127-009-0024-y.
-
(2009)
Int J Ion Mobility Spectrom
, vol.12
, pp. 103-108
-
-
Bödeker, B.1
Baumbach, J.I.2
-
57
-
-
67650062792
-
Peak comparison in MCC/IMS - data - searching for potential biomarkers in human breath data
-
Bödeker B, Vautz W, Baumbach JI (2008) Peak comparison in MCC/IMS - data - searching for potential biomarkers in human breath data. Int J Ion Mobility Spectrom 11: 89-93.
-
(2008)
Int J Ion Mobility Spectrom
, vol.11
, pp. 89-93
-
-
Bödeker, B.1
Vautz, W.2
Baumbach, J.I.3
-
59
-
-
0033050913
-
Variation in volatile organic ompounds in the breath of normal humans
-
Philips M, Herrera J, Krishnan S, Zain M, Greenberg J, Cantaneo RN (1999) Variation in volatile organic ompounds in the breath of normal humans. J Chromatogr B 729: 75-88.
-
(1999)
J Chromatogr B
, vol.729
, pp. 75-88
-
-
Philips, M.1
Herrera, J.2
Krishnan, S.3
Zain, M.4
Greenberg, J.5
Cantaneo, R.N.6
-
60
-
-
78049282979
-
Variation in the levels of volatile trace gases within three hospital environments: implications for clinical breath testing
-
Boshier PR, Cushnir JR, Priest OH, Marczin N, Hanna GB (2010) Variation in the levels of volatile trace gases within three hospital environments: implications for clinical breath testing. J. Breath Res. 4. 031001.
-
(2010)
J. Breath Res
, vol.4
, pp. 031001
-
-
Boshier, P.R.1
Cushnir, J.R.2
Priest, O.H.3
Marczin, N.4
Hanna, G.B.5
-
61
-
-
78649904727
-
Biomarker validation-room air variation during human breath investigations
-
doi: 10. 1007/s12127-010-0044-7
-
Bödecker B, Davies AN, Maddula S, Baumbach JI (2010) Biomarker validation-room air variation during human breath investigations. Int. J. Ion Mobility Spectrom 13, doi: 10. 1007/s12127-010-0044-7.
-
(2010)
Int. J. Ion Mobility Spectrom
, vol.13
-
-
Bödecker, B.1
Davies, A.N.2
Maddula, S.3
Baumbach, J.I.4
|